HOME

TheInfoList



OR:

The standing wave ratio meter, SWR meter, ISWR meter (current "" SWR), or VSWR meter (voltage SWR) measures the
standing wave ratio In radio engineering and telecommunications, standing wave ratio (SWR) is a measure of impedance matching of loads to the characteristic impedance of a transmission line or waveguide. Impedance mismatches result in standing waves along the transmi ...
(SWR) in a
transmission line In electrical engineering, a transmission line is a specialized cable or other structure designed to conduct electromagnetic waves in a contained manner. The term applies when the conductors are long enough that the wave nature of the transmis ...
. The meter indirectly measures the degree of mismatch between a transmission line and its
load Load or LOAD may refer to: Aeronautics and transportation *Load factor (aeronautics), the ratio of the lift of an aircraft to its weight *Passenger load factor, the ratio of revenue passenger miles to available seat miles of a particular transpo ...
(usually an
antenna Antenna ( antennas or antennae) may refer to: Science and engineering * Antenna (radio), also known as an aerial, a transducer designed to transmit or receive electromagnetic (e.g., TV or radio) waves * Antennae Galaxies, the name of two collid ...
). Electronics technicians use it to adjust
radio transmitter In electronics and telecommunications, a radio transmitter or just transmitter is an electronic device which produces radio waves with an antenna. The transmitter itself generates a radio frequency alternating current, which is applied to the ...
s and their antennas and
feedline In a radio antenna, the feed line (feedline), or feeder, is the cable or other transmission line that connects the antenna with the radio transmitter or receiver. In a transmitting antenna, it feeds the radio frequency (RF) current from the ...
s to be impedance matched so they work together properly, and evaluate the effectiveness of other impedance matching efforts.


Directional SWR meter

A directional SWR meter measures the magnitude of the forward and reflected waves by sensing each one individually, with
directional coupler Power dividers (also power splitters and, when used in reverse, power combiners) and directional couplers are passive devices used mostly in the field of radio technology. They couple a defined amount of the electromagnetic power in a transmiss ...
s. A calculation then produces the SWR. Referring to the above diagram, the transmitter (TX) and antenna (ANT) terminals connect via an internal transmission line. This main line is electromagnetically coupled to two smaller sense lines (directional couplers). These are terminated with resistors at one end and diode rectifiers at the other. Some meters use a
printed circuit board A printed circuit board (PCB; also printed wiring board or PWB) is a medium used in Electrical engineering, electrical and electronic engineering to connect electronic components to one another in a controlled manner. It takes the form of a L ...
with three parallel traces to make the transmission line and two sensing lines. The resistors match the characteristic impedance of the sense lines. The diodes convert the magnitudes of the forward and reverse waves to the terminals FWD and REV, respectively, as DC voltages, which are smoothed by the capacitors. The meter or amplifier (not shown) connected to the FWD and REV terminals acts as the required drain resistor, and determines the dwell-time of the meter reading. To calculate the SWR, first calculate the reflection coefficient: :\Gamma = \frac (the voltages should include a relative phase factor). Then calculate the SWR: :\mathsf = \frac ~. In a passive meter, this is usually indicated on a non-linear scale.


Radio operators' SWR meters

For decades radio operators have built and used SWR meters as a simple tuning and diagnostic tool. With shielding compromised, a pair of coax or twinline transmission lines, placed close enough, suffer
crosstalk In electronics, crosstalk is any phenomenon by which a signal transmitted on one circuit or channel of a transmission system creates an undesired effect in another circuit or channel. Crosstalk is usually caused by undesired capacitive, induc ...
. A wave moving in the driven line induces waves in the measurement line. Placed in parallel (straight or loosely coiled) a driven wave reinforces or cancels an induced wave in the same or opposite direction. If the cable pair exceeds half wavelength, cancellation is complete, and power dissipated in matched termination is approximately proportional to the forward and reflected power. The approximation improves as
crosstalk In electronics, crosstalk is any phenomenon by which a signal transmitted on one circuit or channel of a transmission system creates an undesired effect in another circuit or channel. Crosstalk is usually caused by undesired capacitive, induc ...
weakens and harmonic number increases. Over time, nonlinear high gain amplifiers have replaced nonlinear electro-mechanical movements – which replaced incandescent bulbs – to require less cross-talk and improve linear frequency range. Because all frequencies above minimum contribute, the measured ratio is a single frequency quality measure, that increases with unintended harmonics and spurious emissions, as well as actual SWR. By analogy, the measurement cable is a crystal radio (non-discriminating receiver) representing all the radio receivers that might suffer interference from dirty emissions. Though called an SWR Meter, a low measured ratio indicates not only good match, but also clean A3, F3, or G3 emission without excessive harmonics nor spurious (out-of-channel) power.


SWR bridge

SWR can also be measured using an
impedance bridge An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component. In the simpler versions of this instrument the impedance was measured internally and conve ...
. The bridge is balanced (0 Volts across the detector) only when the test impedance exactly matches the reference impedance. When a transmission line is mismatched (), its input impedance deviates from its characteristic impedance; thus, a bridge can be used to determine the presence or absence of a low SWR. To test for a match, the reference impedance of the bridge is set to the expected load impedance (for example, 50 Ohms), and the transmission line connected as the unknown impedance. RF power is applied to the circuit. The voltage at the line input represents the vector sum of the forward wave, and the wave reflected from the load. If we know the characteristic impedance of the line is 50 Ohms, we know the magnitude and phase of the forward wave. It's the same wave present on the other side of the detector. Subtracting this known wave from the wave at the line input yields the reflected wave. Properly designed, a bridge circuit can not only indicate a match, but the degree of mismatch – making it possible to calculate the SWR. This usually involves alternately connecting the reference wave and the reflected wave to a power meter, and comparing the magnitudes of the resulting deflections.


Limitations

An SWR meter does not measure the actual impedance of a load (the resistance and reactance), but only the mismatch ratio. To measure the actual impedance requires an
antenna analyzer An antenna analyzer or in British aerial analyser (also known as a noise bridge, RX bridge, SWR analyzer, or RF analyzer) is a device used for measuring the input impedance of antenna systems in radio electronics applications. In radio communica ...
or other similar RF measuring device. For accurate readings, the SWR meter itself must also match the line's impedance (typically 50 or 75 Ohms). To accommodate multiple impedances, some SWR meters have switches that select the impedance appropriate for the sense lines. An SWR meter should connect to the line as close as possible to the antenna: All practical transmission lines have a certain amount of loss, which attenuates the reflected wave as it travels back along the line. Thus, the SWR is highest closest to the load, and only improves as the distance from the load increases, creating the false impression of a matched system.


Footnotes


References

{{Commons category, SWR meters Measuring instruments Radio electronics