General description
In domestic applications, traps are typically U, S, Q, or J-shaped pipe located below or within a plumbing fixture. An S-shaped trap is also known as an S-bend. It was invented by Alexander Cumming in 1775 but became known as the U-bend following the introduction of the U-shaped trap by Thomas Crapper in 1880. The U-bend could not jam, so, unlike the S-bend, it did not need an overflow. In the United States, traps are commonly referred to as P-traps. It is the addition of a 90 degree fitting on the outlet side of a U-bend, thereby creating a P-like shape (oriented horizontally). It is also referred to as a sink trap because it is installed under most sinks. Because of its shape, the trap retains some water after the fixture's use. This water creates an air seal that prevents sewer gas from passing from the drain pipes back into the building. Essentially all plumbing fixtures including sinks, bathtubs, andHistory
An S-shaped trap is also known as an S-bend. It was invented by Alexander Cumming in 1775 but became known as the U-bend following the introduction of the U-shaped trap by Thomas Crapper in 1880. The new U-bend could not jam, so, unlike the S-bend, it did not need an overflow. Once invented, despite being simple and reasonably reliable, widespread use was slow coming. In Britain, the requirement to use traps was introduced only after theVenting and auxiliary devices
Maintaining the water seal is critical to trap operation; traps might dry out, and poor venting can suction or blow water out of the traps. This is usually avoided by venting the drain pipes downstream of the trap; by being vented to the atmosphere outside the building, the drain lines never operate at a pressure much higher or lower than atmospheric pressure. In the United States, plumbing codes usually provide strict limitations on how far a trap may be located from the nearest ''vent stack''. When a vent cannot be provided, an air admittance valve may be used instead. These devices avoid negative pressure in the drain pipe by venting room air into the drain pipe (behind the trap). A " Chicago Loop" is another alternative. When a trap is installed on a fixture that is not routinely used—such as a floor drain—the eventual evaporation of the water in the trap must be considered. In these cases, a trap primer may be installed; these are devices that automatically recharge traps with water to maintain their water seals.Accepted traps in the United States
In some regions of the US, "S" traps are no longer accepted by the building codes as the unvented S-traps tend to siphon dry. It may be possible to determine whether a household uses an S- or U-bend by the presence of an overflow pipe outlet. What is required instead is a P-trap with proper venting. Certain drum-styled traps are also discouraged or banned. Includes several photographs of various types of drum traps.See also
* Buchan trap, an older type of trap * Drainage * Drain-waste-vent system * Garbage disposal unit * Sanitation * Septic system * Septic tank * Tap water * Water pipeReferences
External links
{{Toilets Plumbing Bathrooms Piping