The roentgen or röntgen (; symbol R) is a legacy unit of measurement for the
exposure of
X-ray
An X-ray, or, much less commonly, X-radiation, is a penetrating form of high-energy electromagnetic radiation. Most X-rays have a wavelength ranging from 10 picometers to 10 nanometers, corresponding to frequencies in the range 30&nb ...
s and
gamma ray
A gamma ray, also known as gamma radiation (symbol γ or \gamma), is a penetrating form of electromagnetic radiation arising from the radioactive decay of atomic nuclei. It consists of the shortest wavelength electromagnetic waves, typically ...
s, and is defined as the
electric charge
Electric charge is the physical property of matter that causes charged matter to experience a force when placed in an electromagnetic field. Electric charge can be ''positive'' or ''negative'' (commonly carried by protons and electrons respe ...
freed by such
radiation
In physics, radiation is the emission or transmission of energy in the form of waves or particles through space or through a material medium. This includes:
* ''electromagnetic radiation'', such as radio waves, microwaves, infrared, visi ...
in a specified
volume
Volume is a measure of occupied three-dimensional space. It is often quantified numerically using SI derived units (such as the cubic metre and litre) or by various imperial or US customary units (such as the gallon, quart, cubic inch). The de ...
of air divided by the
mass
Mass is an intrinsic property of a body. It was traditionally believed to be related to the quantity of matter in a physical body, until the discovery of the atom and particle physics. It was found that different atoms and different elementar ...
of that air (
statcoulomb
The franklin (Fr) or statcoulomb (statC) electrostatic unit of charge (esu) is the physical unit for electrical charge used in the cgs-esu and Gaussian units. It is a derived unit given by
: 1 statC = 1 dyn1/2⋅cm = 1 cm3/2⋅g1/2⋅s−1.
That ...
per kilogram).
In 1928, it was adopted as the first international measurement quantity for
ionising radiation
Ionizing radiation (or ionising radiation), including nuclear radiation, consists of subatomic particles or electromagnetic waves that have sufficient energy to ionize atoms or molecules by detaching electrons from them. Some particles can travel ...
to be defined for
radiation protection
Radiation protection, also known as radiological protection, is defined by the International Atomic Energy Agency (IAEA) as "The protection of people from harmful effects of exposure to ionizing radiation, and the means for achieving this". Expos ...
, as it was then the most easily replicated method of measuring air ionization by using
ion chamber
The ionization chamber is the simplest type of gas-filled radiation detector, and is widely used for the detection and measurement of certain types of ionizing radiation, including X-rays, gamma rays, and beta particles. Conventionally, the term ...
s.
It is named after the
German
German(s) may refer to:
* Germany (of or related to)
**Germania (historical use)
* Germans, citizens of Germany, people of German ancestry, or native speakers of the German language
** For citizens of Germany, see also German nationality law
**Ger ...
physicist
Wilhelm Röntgen
Wilhelm Conrad Röntgen (; ; 27 March 184510 February 1923) was a German mechanical engineer and physicist, who, on 8 November 1895, produced and detected electromagnetic radiation in a wavelength range known as X-rays or Röntgen rays, an achiev ...
, who discovered X-rays and was awarded the first Nobel Prize in Physics for the discovery.
However, although this was a major step forward in standardising radiation measurement, the roentgen has the disadvantage that it is only a measure of air ionisation, and not a direct measure of radiation absorption in other materials, such as different forms of
human tissue
In biology, tissue is a biological organizational level between cells and a complete organ. A tissue is an ensemble of similar cells and their extracellular matrix from the same origin that together carry out a specific function. Organs are ...
. For instance, one roentgen deposits of
absorbed dose
Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass. Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmf ...
in dry air, or in soft tissue.
[ One roentgen of X-rays may deposit anywhere from in bone depending on the beam energy.
As the science of radiation ]dosimetry Radiation dosimetry in the fields of health physics and radiation protection is the measurement, calculation and assessment of the ionizing radiation dose absorbed by an object, usually the human body. This applies both internally, due to ingested o ...
developed, it was realised that the ionising effect, and hence tissue damage, was linked to the energy absorbed, not just radiation exposure. Consequently new radiometric units for radiation protection
Radiation protection, also known as radiological protection, is defined by the International Atomic Energy Agency (IAEA) as "The protection of people from harmful effects of exposure to ionizing radiation, and the means for achieving this". Expos ...
were defined which took this into account. In 1953 the International Commission on Radiation Units and Measurements The International Commission on Radiation Units and Measurements (ICRU) is a standardization body set up in 1925 by the International Congress of Radiology, originally as the X-Ray Unit Committee until 1950. Its objective "is to develop concepts, de ...
(ICRU) recommended the rad, equal to 100 erg/g, as the unit of measure of the new radiation quantity absorbed dose
Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass. Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmf ...
. The rad was expressed in coherent cgs units.
In 1975 the unit gray
Grey (more common in British English) or gray (more common in American English) is an intermediate color between black and white. It is a neutral or achromatic color, meaning literally that it is "without color", because it can be composed o ...
was named as the SI unit of absorbed dose. One gray is equal to 1 J/kg (i.e. 100 rad). Additionally, a new quantity, kerma
Kerma was the capital city of the Kerma culture, which was located in present-day Sudan at least 5,500 years ago. Kerma is one of the largest archaeological sites in ancient Nubia. It has produced decades of extensive excavations and research, in ...
, was defined for air ionisation as the exposure for instrument calibration, and from this the absorbed dose
Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass. Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmf ...
can be calculated using known coefficients for specific target materials. Today, for radiation protection, the modern units, absorbed dose
Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass. Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmf ...
for energy absorption and the equivalent dose
Equivalent dose is a dose quantity '' H '' representing the stochastic health effects of low levels of ionizing radiation on the human body which represents the probability of radiation-induced cancer and genetic damage. It is derived from the ...
(sievert
The sievert (symbol: SvNot be confused with the sverdrup or the svedberg, two non-SI units that sometimes use the same symbol.) is a unit in the International System of Units (SI) intended to represent the stochastic health risk of ionizing radi ...
) for stochastic effect, are overwhelmingly used, and the roentgen is rarely used. The International Committee for Weights and Measures
The General Conference on Weights and Measures (GCWM; french: Conférence générale des poids et mesures, CGPM) is the supreme authority of the International Bureau of Weights and Measures (BIPM), the intergovernmental organization established i ...
(CIPM) has never accepted the use of the roentgen.
The roentgen has been redefined over the years. It was last defined by the U.S.'s National Institute of Standards and Technology
The National Institute of Standards and Technology (NIST) is an agency of the United States Department of Commerce whose mission is to promote American innovation and industrial competitiveness. NIST's activities are organized into physical sci ...
(NIST) in 1998 as , with a recommendation that the definition be given in every document where the roentgen is used.
History
The roentgen has its roots in the Villard unit
Paul Ulrich Villard (28 September 1860 – 13 January 1934) was a French chemist and physicist. He discovered gamma rays in 1900 while studying the radiation emanating from radium.
Early research
Villard was born in Saint-Germain-au-Mont ...
defined in 1908 by the American Roentgen Ray Society
The American Roentgen Ray Society (ARRS) is the first and oldest radiology society in the United States. It was founded in 1900, in the early days of X-ray and radiation study.
Headquartered in Leesburg, Virginia, the society publishes a monthly p ...
as "the quantity of radiation which liberates by ionisation one esu of electricity per cm3 of air under normal conditions of temperature and pressure."[Van Loon, R.; and Van Tiggelen, R.]
''Radiation Dosimetry in Medical Exposure: A Short Historical Overview''
, 2004> Using 1 esu ≈ 3.33564 C and the air density of ~1.293 kg/m3 at 0 °C and 101 kPa, this converts to 2.58 × 10−4 C/kg, which is the modern value given by NIST.
1 × 3.33564 × 10−10 × 1,000,000 ÷ 1.293 = 2.58 × 10−4
This definition was used under different names (e, R, and German unit of radiation) for the next 20 years. In the meantime, the French Roentgen was given a different definition which amounted to 0.444 German R.
ICR definitions
In 1928, the International Congress of Radiology
The International Congress of Radiology (ICR) is a meeting of radiologists for the exchange of ideas and the harmonisation of international standards and practice, first held in 1925 in London and held at regular intervals since then. Since 1994 ...
(ICR) defined the roentgen as "the quantity of X-radiation which, when the secondary electrons are fully utilised and the wall effect of the chamber is avoided, produce in 1 cc of atmospheric air at 0 °C and 76 cm of mercury pressure such a degree of conductivity that 1 esu of charge is measured at saturation current." The stated 1 cc of air would have a mass of 1.293 mg at the conditions given, so in 1937 the ICR rewrote this definition in terms of this mass of air instead of volume, temperature and pressure. The 1937 definition was also extended to gamma rays, but later capped at 3 MeV in 1950.
GOST definition
The USSR
The Soviet Union,. officially the Union of Soviet Socialist Republics. (USSR),. was a transcontinental country that spanned much of Eurasia from 1922 to 1991. A flagship communist state, it was nominally a federal union of fifteen nationa ...
all-union committee of standards
Gosstandart (russian: Госстандарт) was the Soviet government agency responsible for standardization, metrology, and quality management. The name is an abbreviation for ''Gosudarstvennyy standart'' (‘State Standard’).
History
Establ ...
(GOST) had meanwhile adopted a significantly different definition of the roentgen in 1934. GOST standard 7623 defined it as "the physical dose of X-rays which produces charges each of one electrostatic unit in magnitude per cm3 of irradiated volume in air at 0 °C and normal atmospheric pressure when ionization is complete." The distinction of physical dose from dose caused confusion, some of which may have led Cantrill and Parker report that the roentgen had become shorthand for 83 ergs per gram (0.0083 Gy) of tissue. They named this derivative quantity the roentgen equivalent physical Röntgen or Roentgen may refer to:
* Roentgen (unit), unit of measurement for ionizing radiation, named after Wilhelm Röntgen
* Wilhelm Röntgen (1845–1923), German physicist, discoverer of X-rays
* Abraham Roentgen (1711–1793), German cabinet ...
(rep) to distinguish it from the ICR roentgen.
ICRP definition
The introduction of the roentgen measurement unit, which relied upon measuring the ionisation of air, replaced earlier less accurate practices that relied on timed exposure, film exposure, or fluorescence. This led the way to setting exposure limits, and the National Council on Radiation Protection and Measurements The National Council on Radiation Protection and Measurements (NCRP), formerly the National Committee on Radiation Protection and Measurements, and before that the Advisory Committee on X-Ray and Radium Protection (ACXRP), is a U.S. organization. I ...
of the United States
The United States of America (U.S.A. or USA), commonly known as the United States (U.S. or US) or America, is a country primarily located in North America. It consists of 50 states, a federal district, five major unincorporated territorie ...
established the first formal dose limit in 1931 as 0.1 roentgen per day. The International X-ray and Radium Protection Committee
The International Commission on Radiological Protection (ICRP) is an independent, international, non-governmental organization, with the mission to protect people, animals, and the environment from the harmful effects of ionising radiation. Its r ...
, now known as the International Commission on Radiological Protection
The International Commission on Radiological Protection (ICRP) is an independent, international, non-governmental organization, with the mission to protect people, animals, and the environment from the harmful effects of ionising radiation. Its r ...
(ICRP) soon followed with a limit of 0.2 roentgen per day in 1934. In 1950, the ICRP reduced their recommended limit to 0.3 roentgen per week for whole-body exposure.
The International Commission on Radiation Units and Measurements The International Commission on Radiation Units and Measurements (ICRU) is a standardization body set up in 1925 by the International Congress of Radiology, originally as the X-Ray Unit Committee until 1950. Its objective "is to develop concepts, de ...
(ICRU) took over the definition of the roentgen in 1950, defining it as "the quantity of X or γ-radiation such that the associated corpuscular emission per 0.001293 gram of air produces, in air, ions carrying 1 electrostatic unit of quantity of electricity of either sign." The 3 MeV cap was no longer part of the definition, but the degraded usefulness of this unit at high beam energies was mentioned in the accompanying text. In the meantime, the new concept of roentgen equivalent man
The roentgen equivalent man (rem) is a CGS unit of equivalent dose, effective dose, and committed dose, which are dose measures used to estimate potential health effects of low levels of ionizing radiation on the human body.
Quantities measure ...
(rem) had been developed.
Starting in 1957, the ICRP began to publish their recommendations in terms of rem, and the roentgen fell into disuse. The medical imaging
Medical imaging is the technique and process of imaging the interior of a body for clinical analysis and medical intervention, as well as visual representation of the function of some organs or tissues (physiology). Medical imaging seeks to rev ...
community still has a need for ionization measurements, but they gradually converted to using C/kg as legacy equipment was replaced. The ICRU recommended redefining the roentgen to be exactly 2.58 × 10−4 C/kg in 1971.
European Union
In 1971 the European Economic Community
The European Economic Community (EEC) was a regional organization created by the Treaty of Rome of 1957,Today the largely rewritten treaty continues in force as the ''Treaty on the functioning of the European Union'', as renamed by the Lisb ...
, in Directive 71/354/EEC, catalogued the units of measure that could be used "for ... public health ... purposes". The directive included the curie
In computing, a CURIE (or ''Compact URI'') defines a generic, abbreviated syntax for expressing Uniform Resource Identifiers (URIs). It is an abbreviated URI expressed in a compact syntax, and may be found in both XML and non-XML grammars. A CURIE ...
, rad
RAD or Rad may refer to:
People
* Robert Anthony Rad Dougall (born 1951), South African former racing driver
* Rad Hourani, Canadian fashion designer and artist
* Nickname of Leonardus Rad Kortenhorst (1886–1963), Dutch politician
* Radley R ...
, rem
Rem or REM may refer to:
Music
* R.E.M., an American rock band
* ''R.E.M.'' (EP), by Green
* "R.E.M." (song), by Ariana Grande
Organizations
* La République En Marche!, a French centrist political party
* Reichserziehungsministerium, in Nazi G ...
, and roentgen as permissible units, but required that the use of the rad, rem and roentgen be reviewed before 31 December 1977. This document defined the roentgen as exactly 2.58 × 10−4 C/kg, as per the ICRU recommendation. Directive 80/181/EEC
Directive may refer to:
* Directive (European Union), a legislative act of the European Union
* Directive (programming), a computer language construct that specifies how a compiler should process input
* "Directive" (poem), a poem by Robert Frost
...
, published in December 1979, which replaced directive 71/354/EEC, explicitly catalogued the gray
Grey (more common in British English) or gray (more common in American English) is an intermediate color between black and white. It is a neutral or achromatic color, meaning literally that it is "without color", because it can be composed o ...
, becquerel
The becquerel (; symbol: Bq) is the unit of radioactivity in the International System of Units (SI). One becquerel is defined as the activity of a quantity of radioactive material in which one nucleus decays per second. For applications relatin ...
, and sievert
The sievert (symbol: SvNot be confused with the sverdrup or the svedberg, two non-SI units that sometimes use the same symbol.) is a unit in the International System of Units (SI) intended to represent the stochastic health risk of ionizing radi ...
for this purpose and required that the curie, rad, rem and roentgen be phased out by 31 December 1985.
NIST definition
Today the roentgen is rarely used, and the International Committee for Weights and Measures
The General Conference on Weights and Measures (GCWM; french: Conférence générale des poids et mesures, CGPM) is the supreme authority of the International Bureau of Weights and Measures (BIPM), the intergovernmental organization established i ...
(CIPM) never accepted the use of the roentgen. From 1977 to 1998, the US NIST's translations of the SI brochure stated that the CIPM temporarily accepted the use of the roentgen (and other radiology units) with SI units since 1969. However, the only related CIPM decision shown in the appendix are with regards to the curie
In computing, a CURIE (or ''Compact URI'') defines a generic, abbreviated syntax for expressing Uniform Resource Identifiers (URIs). It is an abbreviated URI expressed in a compact syntax, and may be found in both XML and non-XML grammars. A CURIE ...
in 1964. The NIST brochures defined the roentgen as 2.58 × 10−4 C/kg, to be employed with exposures of x or γ radiation, but did not state the medium to be ionized. The CIPM's current SI brochure excludes the roentgen from the tables of non-SI units accepted for use with the SI. The US NIST clarified in 1998 that it was providing its own interpretations of the SI system, whereby it accepted the roentgen for use in the US with the SI, while recognizing that the CIPM did not. By then, the limitation to x and γ radiation had been dropped. NIST recommends defining the roentgen in every document where this unit is used. The continued use of the roentgen is strongly discouraged by the NIST.
Development of replacement radiometric quantities
Although a convenient quantity to measure with an air ion chamber, the roentgen had the disadvantage that it was not a direct measure of either the intensity of X-rays or their absorption, but rather was a measurement of the ionising effect of X-rays in a specific circumstance; which was dry air at 0 °C
The degree Celsius is the unit of temperature on the Celsius scale (originally known as the centigrade scale outside Sweden), one of two temperature scales used in the International System of Units (SI), the other being the Kelvin scale. The ...
and 1 standard atmosphere of pressure.
Because of this the roentgen had a variable relationship to the amount of energy absorbed dose per unit mass in the target material, as different materials have different absorption characteristics. As the science of radiation dosimetry developed, this was seen as a serious shortcoming.
In 1940, Louis Harold Gray
Louis Harold Gray FRS (10 November 1905 – 9 July 1965) was an English physicist who worked mainly on the effects of radiation on biological systems. He was one of the earliest contributors of the field of radiobiology. A summary of his work ...
, who had been studying the effect of neutron damage on human tissue, together with William Valentine Mayneord
William Valentine Mayneord, CBE FRS (14 February 1902 – 10 August 1988) was a British physicist and pioneer in the field of medical physics.
Early life and education
He was born in Redditch, Worcestershire to Walter and Elizabeth Mayneord bu ...
and the radiobiologist John Read, published a paper in which a unit of measure, dubbed the "''gram roentgen''" (symbol: gr) defined as "that amount of neutron radiation which produces an increment in energy in unit volume of tissue equal to the increment of energy produced in unit volume of water by one roentgen of radiation" was proposed. This unit was found to be equivalent to 88 ergs in air. In 1953 the ICRU recommended the rad
RAD or Rad may refer to:
People
* Robert Anthony Rad Dougall (born 1951), South African former racing driver
* Rad Hourani, Canadian fashion designer and artist
* Nickname of Leonardus Rad Kortenhorst (1886–1963), Dutch politician
* Radley R ...
, equal to 100 erg/g, as the new unit of measure of absorbed radiation. The rad was expressed in coherent cgs units.
In the late 1950s the General Conference on Weights and Measures
The General Conference on Weights and Measures (GCWM; french: Conférence générale des poids et mesures, CGPM) is the supreme authority of the International Bureau of Weights and Measures (BIPM), the intergovernmental organization established i ...
(CGPM) invited the ICRU to join other scientific bodies to work with the International Committee for Weights and Measures
The General Conference on Weights and Measures (GCWM; french: Conférence générale des poids et mesures, CGPM) is the supreme authority of the International Bureau of Weights and Measures (BIPM), the intergovernmental organization established i ...
(CIPM) in the development of a system of units that could be used consistently over many disciplines. This body, initially known as the "Commission for the System of Units", renamed in 1964 as the "Consultative Committee for Units" (CCU), was responsible for overseeing the development of the International System of Units
The International System of Units, known by the international abbreviation SI in all languages and sometimes pleonastically as the SI system, is the modern form of the metric system and the world's most widely used system of measurement. E ...
(SI). At the same time it was becoming increasingly obvious that the definition of the roentgen was unsound, and in 1962 it was redefined.
The CCU decided to define the SI unit of absorbed radiation in terms of energy per unit mass, which in MKS units was J/kg. This was confirmed in 1975 by the 15th CGPM, and the unit was named the "gray" in honour of Louis Harold Gray, who had died in 1965. The gray was equal to 100 rad. The definition of the roentgen had had the attraction of being relatively simple to define for photons in air, but the gray is independent of the primary ionizing radiation type, and can be used for both kerma and absorbed dose in a wide range of matter.
When measuring absorbed dose
Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass. Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmf ...
in a human due to external exposure, the SI unit the gray
Grey (more common in British English) or gray (more common in American English) is an intermediate color between black and white. It is a neutral or achromatic color, meaning literally that it is "without color", because it can be composed o ...
, or the related non-SI rad
RAD or Rad may refer to:
People
* Robert Anthony Rad Dougall (born 1951), South African former racing driver
* Rad Hourani, Canadian fashion designer and artist
* Nickname of Leonardus Rad Kortenhorst (1886–1963), Dutch politician
* Radley R ...
are used. From these can be developed the dose equivalents to consider biological effects from differing radiation types and target materials. These are equivalent dose
Equivalent dose is a dose quantity '' H '' representing the stochastic health effects of low levels of ionizing radiation on the human body which represents the probability of radiation-induced cancer and genetic damage. It is derived from the ...
, and effective dose for which the SI unit sievert
The sievert (symbol: SvNot be confused with the sverdrup or the svedberg, two non-SI units that sometimes use the same symbol.) is a unit in the International System of Units (SI) intended to represent the stochastic health risk of ionizing radi ...
or the non-SI rem
Rem or REM may refer to:
Music
* R.E.M., an American rock band
* ''R.E.M.'' (EP), by Green
* "R.E.M." (song), by Ariana Grande
Organizations
* La République En Marche!, a French centrist political party
* Reichserziehungsministerium, in Nazi G ...
are used.
Radiation-related quantities
The following table shows radiation quantities in SI and non-SI units:
See also
* Gray (unit)
The gray (symbol: Gy) is the unit of ionizing radiation dose in the International System of Units (SI), defined as the absorption of one joule of radiation energy per kilogram of matter.
It is used as a unit of the radiation quantity absorbed do ...
– SI unit of absorbed dose
* Orders of magnitude (radiation)
Recognized effects of higher acute radiation doses are described in more detail in the article on radiation poisoning. Although the International System of Units (SI) defines the sievert (Sv) as the unit of radiation dose equivalent, chronic radi ...
* Rad (unit)
The rad is a unit of absorbed radiation dose, defined as 1 rad = 0.01 Gy = 0.01 J/kg. It was originally defined in CGS units in 1953 as the dose causing 100 ergs of energy to be absorbed by one gram of matter. The material absorbing the radiat ...
– cgs unit of absorbed dose
* Roentgen equivalent man
The roentgen equivalent man (rem) is a CGS unit of equivalent dose, effective dose, and committed dose, which are dose measures used to estimate potential health effects of low levels of ionizing radiation on the human body.
Quantities measure ...
, or rem – a unit of radiation dose equivalent
* Sievert
The sievert (symbol: SvNot be confused with the sverdrup or the svedberg, two non-SI units that sometimes use the same symbol.) is a unit in the International System of Units (SI) intended to represent the stochastic health risk of ionizing radi ...
(symbol: Sv) – the SI derived unit of dose equivalent
* Wilhelm Röntgen
Wilhelm Conrad Röntgen (; ; 27 March 184510 February 1923) was a German mechanical engineer and physicist, who, on 8 November 1895, produced and detected electromagnetic radiation in a wavelength range known as X-rays or Röntgen rays, an achiev ...
References
External links
NIST: Units outside the SI
– Health Physics Society
{{DEFAULTSORT:Roentgen
Units of radiation dose
Non-SI metric units