HOME

TheInfoList



OR:

Pupillometry, the measurement of
pupil The pupil is a black hole located in the center of the Iris (anatomy), iris of the Human eye, eye that allows light to strike the retina.Cassin, B. and Solomon, S. (1990) ''Dictionary of Eye Terminology''. Gainesville, Florida: Triad Publishing ...
size and reactivity, is a key part of the clinical neurological exam for patients with a wide variety of neurological injuries. It is also used in
psychology Psychology is the scientific study of mind and behavior. Psychology includes the study of conscious and unconscious phenomena, including feelings and thoughts. It is an academic discipline of immense scope, crossing the boundaries betwe ...
.


Pupillometry in critical care

For more than 100 years, clinicians have evaluated the pupils of patients with suspected or known brain injury or impaired consciousness to monitor neurological status and trends, checking for pupil size and reactivity to light. In fact, before the advent of electricity, doctors checked a patient’s reaction to light using a candle. Today, clinicians routinely evaluate pupils as a component of the neurological examination and monitoring of critically ill patients, including patients with traumatic brain injury and stroke. In 2019, the first smartphone based pupillometer was released as an accurate and economical way to objectively determine pupil size and dynamic response.


Patient care and outcome

Numerous studies have shown the importance of pupil evaluation in the clinical setting, and pupillary information is used extensively in patient management and as an indication for possible medical intervention. Patients who undergo prompt intervention after a new finding of pupil abnormality have a better chance of recovery. Alterations of the pupil light reflex, size of the pupil, and anisocoria (unequal pupils) are correlated with outcomes of patients with traumatic brain injury. Blood flow imaging has shown that pupil changes are highly correlated with brainstem oxygenation and perfusion, and anisocoria can be an indicator of a pathological process or neurological dysfunction. Investigators have used pupil size and reactivity as fundamental parameters of outcome predictive models in conjunction with other clinical information such as age, mechanism of injury, and Glasgow Coma Scale, and have correlated the models with the presence and location of intracranial mass lesions. The ''National Institutes of Health Stroke Scale'' (NIHSS) uses pupillary response as a systematic assessment tool to provide a quantitative measure of stroke-related neurologic deficit and to evaluate acuity of stroke patients, determine appropriate treatment, and predict patient outcome.


Manual vs. automated pupil assessment

Traditionally, pupil measurements have been performed in a subjective manner by using a penlight or flashlight to manually evaluate pupil reactivity and using a pupil gauge to estimate pupil size. However, manual pupillary assessment is subject to significant inaccuracies and inconsistencies. Studies have shown inter-examiner disagreement in the manual evaluation of pupillary reaction to be as high as 39 percent.Olson D, Stutzman S, Saju C, Wilson M, Zhao W, Aiyagari V. Interrater reliability of pupillary assessments. ''Neurocritical Care.'' 2015.Stutzman S, Olson D, Saju C, Wilson M, Aiyagari V. Interrater reliability of pupillar assessments among physicians and nurses. UT Southwestern Medical Center; 2014. Automated pupillometry involves the use of a pupillometer, a portable, handheld device that provides a reliable and objective measurement of pupillary size, symmetry, and reactivity through measurement of the pupil light reflex. Pupillometers before 2018 predominately used infrared cameras to observe pupil diameter. Then, in 2019, advancements in machine learning have enabled visual spectrum pupillometry using a smartphone. Numeric scales allow for a more rigorous interpretation and classification of the pupil response and are a primary feature of both hardware and software based pupillometers. Automated pupillometry removes subjectivity from the pupillary evaluation, providing more accurate and trendable pupil data, and allowing earlier detection of changes for more timely patient treatment. By using automated pupillometers and algorithms such as Reflex's "Reflex Score", doctors can easily and objectively assess pupil reactivity that could otherwise be missed by manual assessment. Automated pupillometers have been proven to be more effective than manual pupil assessment
Mobile visual spectrum automated pupillometers
have been proven effective as an alternative to infrared pupillometers that typically command a higher cost. Controversy has risen around infrared pupillometers as they are routinely incapable of measuring hippus, a natural pupillary phenomenon, which has professionals concluding that NeurOptics' devices fit a curve to measured data. Infrared pupillometers use an eye guard that is placed on a subject's orbit or
zygomatic bone In the human skull, the zygomatic bone (from grc, ζῠγόν, zugón, yoke), also called cheekbone or malar bone, is a paired irregular bone which articulates with the maxilla, the temporal bone, the sphenoid bone and the frontal bone. It is s ...
and uses a fixed distance calibration to determine pupil size which has further brought into question the validity of fixed distance measures as the human population varies widely in skull structure. According to the new American Heart Association guidelines, most deaths attributable to post-cardiac arrest brain injury are due to active withdrawal of life-sustaining treatment based on a predicted poor neurological outcome. The NPi and automated pupillometry have recently been included in the updated 2020 American Heart Association (AHA) Guidelines for Cardiopulmonary Resuscitation (CPR) and Emergency Cardiovascular Care (ECC) as an object measurement supporting brain injury prognosis in patients following cardiac arrest. A study published in the ''Journal of Neurosurgery'' found that automated pupillometers may signal an early warning of potential delayed cerebral ischemia and enable preemptive escalation of care. The ''American Journal of Critical Care'' revealed that critical care and neurosurgical nurses consistently underestimated pupil size, were unable to identify anisocoria, and incorrectly assessed pupil reactivity. It concluded that automated pupillometry is a necessary tool for accuracy and consistency, and that it might facilitate earlier detection of subtle pupil changes, allowing more effective and timely diagnostic and treatment interventions. In addition, a study from The University of Texas Southwestern Medical Center compared 2,329 manual pupillary exams performed simultaneously by two examiners (neurology and neurosurgery attending and resident physicians, staff nurses, and mid-level practitioners) under identical conditions and showed low inter-examiner reliability. The ''American Association of Critical-Care Nurses'' ''(AACN) Procedure Manual for High Acuity, Progressive and Critical Care, 7th Edition,'' and the ''American Association of Neuroscience Nurses (AANN) Core Curriculum for Neuroscience Nursing, 6th Edition,'' now include sections illustrating how use of a pupillometer removes subjectivity and allows pupillary reactivity to be trended in a consistent, objective, and quantifiable way. The AACN Procedure Manual, which was extensively reviewed by more than 100 experts in critical care nursing, is the authoritative reference for procedures performed in critical care settings, and the AANN curriculum is a comprehensive resource for practicing neuroscience nurses. Advancements in mobile-based automated pupillometry have been made in recent years to accommodate for the growing number of mobile phones being used in healthcare. Notably, brightlamp, Inc. has secured the first intellectual property relating to mobile quantitative pupillometry.


Pupillometry in psychology


Stimulants


Photographs

Hess and Polt (1960) presented pictures of semi-naked adults and babies to adults (four men and two women). Pupils of both sexes dilated after seeing pictures of people of the opposite sex. In females, the difference in pupil size occurred also after seeing pictures of babies and mothers with babies. This examination showed that pupils react not only to the changes of intensity of light (
pupillary light reflex The pupillary light reflex (PLR) or photopupillary reflex is a reflex that controls the diameter of the pupil, in response to the intensity (luminance) of light that falls on the retinal ganglion cells of the retina in the back of the eye, there ...
) but also reflect arousal or emotions. In 1965 Hess, Seltzer and Shlien examined pupillary responses in heterosexual and homosexual males. Results showed a greater pupil dilation to pictures of the opposite sex for heterosexuals and to pictures of the same sex for homosexuals. According to T.M. Simms (1967), pupillary responses of males and females were greater when they were exposed to pictures of the opposite sex. In another study, Nunnally and colleagues (1967) found that seeing slides rated as 'very pleasant' was associated with greater pupil dilation as seeing slides rated as neutral or very unpleasant. Infants showed greater pupil size when they saw pictures of faces than when they saw geometric shapes, and greater dilation after seeing pictures of the infant's mother than pictures of a stranger.


Cognitive load

Pupillary responses can reflect activation of the brain allocated to cognitive tasks. Greater pupil dilation is associated with increased processing in the brain. Vacchiano and colleagues (1968) found that pupillary responses were associated with visual exposure to words with high, neutral or low value. Presented low-value words were associated with dilation, and high-value words with constriction of a pupil. In decision-making tasks dilation increased before the decision as a function of
cognitive load In cognitive psychology, cognitive load refers to the amount of working memory resources used. There are three types of cognitive load: ''intrinsic'' cognitive load is the effort associated with a specific topic; ''extraneous'' cognitive load refe ...
. In an experiment about short-term serial memory, students heard strings of words and were asked to repeat them. Greater pupil diameter was observed after the items were heard (depending on how many items were heard), and decreased after items were repeated. The more difficult the task, the greater pupil diameter observed from the time preceding the solution until the task was completed.


Long-term memory

The pupil response reflects long-term memory processes both at encoding, predicting the success of memory formation and at retrieval, reflecting different recognition outcomes.


See also

*
Pupil The pupil is a black hole located in the center of the Iris (anatomy), iris of the Human eye, eye that allows light to strike the retina.Cassin, B. and Solomon, S. (1990) ''Dictionary of Eye Terminology''. Gainesville, Florida: Triad Publishing ...
*
Pupilometer Pupilometer, also spelled pupillometer, is a name for two different devices—one used to measure the pupillary light reflex, and the other used in ophthalmology, which measures the distance between pupils through visual stimuli. Automated Pupillo ...
*
Neurological Pupil index (NPi) Clinicians routinely check the pupils of critically injured and ill patients to monitor neurological status. However, manual pupil measurements (performed using a penlight or ophthalmoscope) have been shown to be subjective, inaccurate, and not repe ...
*
Psychophysiology Psychophysiology (from Ancient Greek, Greek , ''psȳkhē'', "breath, life, soul"; , ''physis'', "nature, origin"; and , ''wiktionary:-logia, -logia'') is the branch of psychology that is concerned with the physiology, physiological bases of psych ...


References


Further reading

* * {{cite journal , last1 = Verney , first1 = S. P. , last2 = Granholm , first2 = E. , last3 = Dionisio , first3 = D. P. , year = 2001 , title = Pupillary responses and processing resources on the visual backward masking task , url = http://www.unm.edu/~sverney/IntlJPsychophysVerney.pdf , archive-url = https://wayback.archive-it.org/all/20080221193653/http://www.unm.edu/~sverney/IntlJPsychophysVerney.pdf , url-status = dead , archive-date = 2008-02-21 , journal = Psychophysiology , volume = 38 , issue = 1 , pages = 76–83 , doi = 10.1111/1469-8986.3810076 , pmid = 11321622 , access-date = 2012-10-01 * Beatty J. (1977), "Pupillometric Measurement of Cognitive Workload

Neuropsychological tests Human pupil