HOME

TheInfoList



OR:

Power usage effectiveness (PUE) is a ratio that describes how efficiently a computer
data center A data center (American English) or data centre (British English)See spelling differences. is a building, a dedicated space within a building, or a group of buildings used to house computer systems and associated components, such as telecommunic ...
uses energy; specifically, how much energy is used by the computing equipment (in contrast to cooling and other overhead that supports the equipment). PUE is the ratio of the total amount of energy used by a computer
data center A data center (American English) or data centre (British English)See spelling differences. is a building, a dedicated space within a building, or a group of buildings used to house computer systems and associated components, such as telecommunic ...
facility to the
energy In physics, energy (from Ancient Greek: ἐνέργεια, ''enérgeia'', “activity”) is the quantitative property that is transferred to a body or to a physical system, recognizable in the performance of work and in the form of heat a ...
delivered to computing equipment. PUE is the inverse of
data center infrastructure efficiency Data center infrastructure efficiency (DCIE), is a performance improvement metric used to calculate the energy efficiency of a data center. DCIE is the percentage value derived, by dividing information technology equipment power by total facility po ...
. PUE was originally developed by a
consortium A consortium (plural: consortia) is an association of two or more individuals, companies, organizations or governments (or any combination of these entities) with the objective of participating in a common activity or pooling their resources for ...
called
The Green Grid The Green Grid is a nonprofit, industry consortium of end-users, policy-makers, technology providers, facility architects, and utility companies collaborating to improve the resource efficiency of data centers. At one time it had more than 175 ...
. PUE was published in 2016 as a global standard under ISO/IEC 30134-2:2016 An ideal PUE is 1.0. Anything that isn't considered a computing device in a data center (e.g. lighting, cooling, etc.) falls into the category of facility energy consumption. : \mathrm = = 1 +


Issues and problems with the power usage effectiveness

The PUE metric is the most popular method of calculating energy efficiency. Although it is the most effective in comparison to other metrics, PUE comes with its share of flaws. This is the most frequently used metric for operators, facility technicians, and building architects to determine how energy efficient their data center buildings are. Some professionals even brag about their PUE being lower than others. Naturally, it is not a surprise that in some cases an operator may “accidentally” not count the energy used for lighting, resulting in lower PUE. This problem is more linked to a human mistake, rather than an issue with the PUE metric system itself. One real problem is PUE does not account for the climate within the cities the data centers are built. In particular, it does not account for different normal temperatures outside the data center. For example, a data center located in Alaska cannot be effectively compared to a data center in Miami. A colder climate results in a lesser need for a massive cooling system. Cooling systems account for roughly 30 percent of consumed energy in a facility, while the data center equipment accounts for nearly 50 percent. Due to this, the Miami data center may have a final PUE of 1.8 and the data center in Alaska may have a ratio of 1.7, but the Miami data center may be running overall more efficiently. In particular, if it happened to be in Alaska, it may get a better result. Additionally, according to a case study on
Science Direct ScienceDirect is a website which provides access to a large bibliographic database of scientific and medical publications of the Dutch publisher Elsevier. It hosts over 18 million pieces of content from more than 4,000 academic journals and 30,0 ...
, "an estimated PUE is practically meaningless unless the IT is working at full capacity".Brady, Gemma, Nikil Kapur, Jonathan Summers, and Harvey Thompson.
A Case Study and Critical Assessment in Calculating Power Usage Effectiveness for a Data Centre
" Energy Conversion & Management, 76 (2013): 155-161.
All in all, finding simple, yet recurring issues such as the problems associated with the effect of varying temperatures in cities and learning how to properly calculate all the facility energy consumption is very essential. By doing so, continuing to reduce these problems ensures that further progress and higher standards are always being pushed to improve the success of the PUE for future data center facilities. To get precise results from an efficiency calculation, all the data associated with the data center must be included. Even a small mistake can cause many differences in PUE results. One practical problem that is frequently noticed in typically data centers include adding the energy endowment of any alternate energy generation systems (such as wind turbines and solar panels) running in parallel with the data center to the PUE, leading to an obfuscation of the true data center performance. Another problem is that some devices that consume power and are associated with a data center may actually share energy or uses elsewhere, causing a huge error on PUE.


Benefits and limitation

PUE was introduced in 2006 and promoted by The Green Grid (a non-profit organization of IT professionals) in 2007, and has become the most commonly used metric for reporting the energy efficiency of data centres. Although it is named "power usage effectiveness", it actually measures the energy use of the data centre. The PUE metric has several important benefits. First, the calculation can be repeated over time, allowing a company to view their efficiency changes historically, or during time-limited events like seasonal changes. Second, companies can gauge how more efficient practices (such as powering down idle hardware) affect their overall usage. Finally, the PUE metric creates competition, “driving efficiencies up as advertised PUE values become lower". Companies can then use PUE as a marketing tool. However, there are some issues with the PUE metric. Rather than the issues mentioned in the last paragraph, some other issues are the efficiency of the power supply network and calculating the accurate IT load. According to the sensitivity analysis by Gemma, "Total energy consumption is equal to the total amount of energy used by the equipment and infrastructure in the facility (WT) plus the energy losses due to inefficiencies in the power delivery network (WL), hence: PUE=(WT+WL)/WIT." Based on the equation, the inefficiencies of the power delivery network (WL) will increase the total energy consumption of the data center. The PUE value goes up as the data center becomes less efficient. IT load is another important issue of the PUE metric. "It is crucial that an accurate IT load is used for the PUE, and that it is not based upon the rated power use of the equipment. Accuracy in the IT load is one of the major factors affecting the measurement of the PUE metric, as utilization of the servers has an important effect on IT energy consumption and hence the overall PUE value". For example, a data center with high PUE value and high server utilization could be more efficient than a data center with low PUE value and low server utilization. There is also some concern within the industry of PUE as a marketing tool leading some to use the term "PUE Abuse".


Notably efficient companies

In October 2008, Google's data center was noted to have a ratio of 1.21 PUE across all 6 of its centers, which at the time was considered as close to perfect as possible. Right behind Google was Microsoft, which had another notable PUE ratio of 1.22. Since 2015,
Switch In electrical engineering, a switch is an electrical component that can disconnect or connect the conducting path in an electrical circuit, interrupting the electric current or diverting it from one conductor to another. The most common type of ...
, the developer of SUPERNAP data centers, has had a third party audited colocation PUE of 1.18 for its SUPERNAP 7 Las Vegas, Nevada facility, with an average cold aisle temp of and average humidity of 40.3%. This is attributed to Switch’s patented hot aisle containment and HVAC technologies. As of the end of Q2 2015, Facebook's Prineville data center had a power usage effectiveness (PUE) of 1.078 and its Forest City data center had a PUE of 1.082. In October 2015, Allied Control has a claimed PUE ratio of 1.02 through the use of two-phase immersion cooling using 3M Novec 7100 fluid. In January 2016, the ''Green IT Cube'' in
Darmstadt Darmstadt () is a city in the States of Germany, state of Hesse in Germany, located in the southern part of the Frankfurt Rhine Main Area, Rhine-Main-Area (Frankfurt Metropolitan Region). Darmstadt has around 160,000 inhabitants, making it th ...
was dedicated with a 1.07 PUE. It uses cold water cooling through the rack doors. In February 2017,
Supermicro Super Micro Computer, Inc., dba Supermicro, is an information technology company based in San Jose, California. It has manufacturing operations in the Silicon Valley, the Netherlands and at its Science and Technology Park in Taiwan. Founded on ...
has announced deployment of its disaggregated MicroBlade systems. An unnamed
Fortune 100 The ''Fortune'' 500 is an annual list compiled and published by ''Fortune'' magazine that ranks 500 of the largest United States corporations by total revenue for their respective fiscal years. The list includes publicly held companies, along w ...
company has deployed over 30,000 Supermicro MicroBlade servers at its Silicon Valley data center with a (PUE) of 1.06. Through proprietary innovations in liquid cooling systems, French hosting company
OVH OVH, legally OVH Groupe SAS, is a French cloud computing company which offers VPS, dedicated servers and other web services. As of 2016 OVH owned the world's largest data center in surface area. As of 2019, it was the largest hosting provide ...
has managed to attain a PUE ratio of 1.09 in its data centers in Europe and North America.


Standards

PUE was published in 2016 as a global standard unde
ISO/IEC 30134-2:2016
as well as a European standard unde
EN 50600-4-2:2016


See also

*
Data center infrastructure efficiency Data center infrastructure efficiency (DCIE), is a performance improvement metric used to calculate the energy efficiency of a data center. DCIE is the percentage value derived, by dividing information technology equipment power by total facility po ...
*
Performance per watt In computing, performance per watt is a measure of the energy efficiency of a particular computer architecture or computer hardware. Literally, it measures the rate of computation that can be delivered by a computer for every watt of power consume ...
* Green power usage effectiveness *
Green computing Green computing, green IT, or ICT sustainability, is the study and practice of environmentally sustainable computing or IT. The goals of green computing are similar to green chemistry: reduce the use of hazardous materials, maximize energy effici ...
*
IT energy management IT energy management or Green IT is the analysis and management of energy demand within the Information Technology department in any organization. IT energy demand accounts for approximately 2% of global emissions, approximately the same level a ...
* WUE


References

{{reflist Benchmarks (computing) Energy conservation Electric power