A power cable is an
electrical cable
An electrical cable is an assembly of one or more wires running side by side or bundled, which is used to carry electric current.
One or more electrical cables and their corresponding connectors may be formed into a ''cable assembly'', which ...
, an assembly of one or more electrical
conductors, usually held together with an overall sheath. The assembly is used for transmission of
electrical power
Electric power is the rate at which electrical energy is transferred by an electric circuit. The SI unit of power is the watt, one joule per second. Standard prefixes apply to watts as with other SI units: thousands, millions and billions of ...
. Power cables may be installed as permanent
wiring
Electrical wiring is an electrical installation of cabling and associated devices such as switches, distribution boards, sockets, and light fittings in a structure.
Wiring is subject to safety standards for design and installation. Allowable ...
within buildings, buried in the ground, run overhead, or exposed. Power cables that are bundled inside thermoplastic sheathing and that are intended to be run inside a building are known as NM-B (nonmetallic sheathed building cable).
Flexible power cables are used for portable devices, mobile tools, and machinery.
History
The first power distribution system developed by
Thomas Edison
Thomas Alva Edison (February 11, 1847October 18, 1931) was an American inventor and businessman. He developed many devices in fields such as electric power generation, mass communication, sound recording, and motion pictures. These inventio ...
in 1882 in New York City used
copper
Copper is a chemical element with the symbol Cu (from la, cuprum) and atomic number 29. It is a soft, malleable, and ductile metal with very high thermal and electrical conductivity. A freshly exposed surface of pure copper has a pinkis ...
rods, wrapped in jute and placed in rigid pipes filled with a
bituminous
Asphalt, also known as bitumen (, ), is a sticky, black, highly viscous liquid or semi-solid form of petroleum. It may be found in natural deposits or may be a refined product, and is classed as a pitch. Before the 20th century, the term a ...
compound. Although vulcanized rubber had been patented by Charles Goodyear in 1844, it was not applied to cable insulation until the 1880s, when it was used for lighting circuits. Rubber-insulated cable was used for 11,000-volt circuits in 1897 installed for the
Niagara Falls
Niagara Falls () is a group of three waterfalls at the southern end of Niagara Gorge, spanning the border between the province of Ontario in Canada and the state of New York in the United States. The largest of the three is Horseshoe Falls, ...
power project.
Mass-impregnated paper-insulated medium voltage cables were commercially practical by 1895. During
World War II
World War II or the Second World War, often abbreviated as WWII or WW2, was a world war that lasted from 1939 to 1945. It involved the vast majority of the world's countries—including all of the great powers—forming two opposin ...
several varieties of
synthetic rubber
A synthetic rubber is an artificial elastomer. They are polymers synthesized from petroleum byproducts. About 32-million metric tons of rubbers are produced annually in the United States, and of that amount two thirds are synthetic. Synthetic rubbe ...
and
polyethylene
Polyethylene or polythene (abbreviated PE; IUPAC name polyethene or poly(methylene)) is the most commonly produced plastic. It is a polymer, primarily used for packaging ( plastic bags, plastic films, geomembranes and containers including bo ...
insulation were applied to cables.
Typical residential and office construction in North America has gone through several technologies:
* Early bare and cloth-covered wires installed with staples
*
Knob and tube wiring
Knob or KNOB may refer to:
Objects
* A round handle
** Doorknob
** Control knob, controls a device
** Brodie knob, on a steering wheel
* Tow ball or hitch ball
* Dorset knob, a biscuit
Landforms
* A rounded hill or mountain, particularly in ...
, 1880s-1930s, using asphalt-saturated cloth or later rubber insulation
* Armored cable, known by the genericized trademark "BX" - flexible steel sheath with two cloth-covered, rubber-insulated conductors
- introduced in 1906 but more expensive than open single conductors
* Rubber-insulated wires with jackets of woven cotton cloth (usually impregnated with tar), waxed paper filler - introduced in 1922
* Modern two or three-wire+ground
PVC-insulated cable (e.g., NM-B), produced by such brands as Romex®
* Aluminum wire was used in the 1960s and 1970s as a cheap replacement for copper and is still used today, but this is now considered unsafe, without proper installation, due to corrosion, softness and creeping of connection.
*
Asbestos
Asbestos () is a naturally occurring fibrous silicate mineral. There are six types, all of which are composed of long and thin fibrous crystals, each fibre being composed of many microscopic "fibrils" that can be released into the atmosphere b ...
was used as an
Insulator (electricity)
An electrical insulator is a material in which electric current does not flow freely. The atoms of the insulator have tightly bound electrons which cannot readily move. Other materials—semiconductors and conductors—conduct electric current ...
in some cloth wires from the 1920s to 1970s, but discontinued due to its health risk.
*
Teck cable, a PVC-sheathed armored cable
Construction
Modern power cables come in a variety of sizes, materials, and types, each particularly adapted to its uses. Large single insulated conductors are also sometimes called power cables in the industry.
Cables consist of three major components: conductors, insulation, protective jacket. The makeup of individual cables varies according to application. The construction and material are determined by three main factors:
* Working voltage, determining the thickness of the insulation;
* Current-carrying capacity, determining the cross-sectional size of the conductor(s);
* Environmental conditions such as temperature, water, chemical or sunlight exposure, and mechanical impact, determining the form and composition of the outer cable jacket.
Cables for direct burial or for exposed installations may also include metal armor in the form of wires spiraled around the cable, or a corrugated tape wrapped around it. The armor may be made of steel or aluminum, and although connected to earth ground is not intended to carry current during normal operation. Electrical power cables are sometimes installed in raceways, including
electrical conduit and cable trays, which may contain one or more conductors. When it is intended to be used inside a building, nonmetallic sheathed building cable (NM-B) consists of two or more wire conductors (plus a grounding conductor) enclosed inside a thermoplastic insulation sheath that is heat-resistant. It has advantages over armored building cable because it's lighter, easier to handle, and its sheathing is easier to work with.
Power cables use stranded
copper
Copper is a chemical element with the symbol Cu (from la, cuprum) and atomic number 29. It is a soft, malleable, and ductile metal with very high thermal and electrical conductivity. A freshly exposed surface of pure copper has a pinkis ...
or
aluminum
Aluminium (aluminum in American and Canadian English) is a chemical element with the symbol Al and atomic number 13. Aluminium has a density lower than those of other common metals, at approximately one third that of steel. It has ...
conductors, although small power cables may use solid conductors in sizes of up to 1/0. (''For a detailed discussion on copper cables, see:
Copper wire and cable
Copper has been used in electrical wiring since the invention of the electromagnet and the telegraph in the 1820s. The invention of the telephone in 1876 created further demand for copper wire as an electrical conductor.
Copper is the electri ...
.''). The cable may include uninsulated conductors used for the circuit neutral or for ground (earth) connection. The grounding conductor connects the equipment's enclosure/chassis to ground for protection from electric shock. These uninsulated versions are known are bare conductors or tinned bare conductors. The overall assembly may be round or flat. Non-conducting filler strands may be added to the assembly to maintain its shape. Filler materials can be made in non-hydroscopic versions if required for the application.
Special purpose power cables for overhead applications are often bound to a high strength alloy, ACSR, or alumoweld messenger. This cable is called aerial cable or pre-assembled aerial cable (PAC). PAC can be ordered unjacketed, however, this is less common in recent years due to the low added cost of supplying a polymeric jacket. For vertical applications the cable may include armor wires on top of the jacket, steel or
Kevlar
Kevlar (para-aramid) is a strong, heat-resistant synthetic fiber, related to other aramids such as Nomex and Technora. Developed by Stephanie Kwolek at DuPont in 1965, the high-strength material was first used commercially in the early 1970s a ...
. The armor wires are attached to supporting plates periodically to help support the weight of the cable. A supporting plate may be included on each floor of the building, tower, or structure. This cable would be called an armored riser cable. For shorter vertical transitions (perhaps 30–150 feet) an unarmored cable can be used in conjunction with basket (Kellum) grips or even specially designed duct plugs.
Material specification for the cable's jacket will often consider resistance to water, oil, sunlight, underground conditions, chemical vapors, impact, fire, or high temperatures. In nuclear industry applications the cable may have special requirements for ionizing radiation resistance. Cable materials for a transit application may be specified not to produce large amounts of smoke if burned (low smoke zero halogen). Cables intended for direct burial must consider damage from backfill or dig-ins. HDPE or polypropylene jackets are common for this use. Cables intended for subway (underground vaults) may consider oil, fire resistance, or low smoke as a priority. Few cables these days still employ an overall lead sheath. However, some utilities may still install paper insulated lead covered cable in distribution circuits. Transmission or submarine cables are more likely to use lead sheaths. However, lead is in decline and few manufacturers exist today to produce such items. When cables must run where exposed to mechanical damage (industrial sites), they may be protected with flexible steel tape or wire armor, which may also be covered by a water-resistant jacket.
A hybrid cable can include conductors for control signals or may also include
optical fibers
An optical fiber, or optical fibre in Commonwealth English, is a flexible, transparent fiber made by drawing glass (silica) or plastic to a diameter slightly thicker than that of a human hair. Optical fibers are used most often as a means ...
for data.
Higher voltages
For circuits operating at or above 2,000 volts between conductors, a conductive shield will surround the conductor's insulation. This equalizes electrical stress on the cable insulation. This technique was patented by Martin Hochstadter in 1916;
[Underground Systems] the shield is sometimes called a Hochstadter shield. Aside from the semi conductive ("semicon") insulation shield, there will also be a conductor shield. The conductor shield may be semi conductive or non conducting. Only one cable company produces non conductive conductor shields though. The purpose of the conductor shield is similar to the insulation shield: it is a void filler and voltage stress equalizer.
To drain off stray voltage, a metallic shield will be placed over the "semicon." This shield is intended to "make safe" the cable by pulling the voltage on the outside of the insulation down to zero (or at least under the OSHA limit of 50 volts). This metallic shield can consist of a thin copper tape, concentric drain wires, flat straps, lead sheath, or other designs. The metallic shields of a cable are connected to earth ground at the ends of the cable, and possibly locations along the length if voltage rise during
faults would be dangerous. Multi-point grounding is the most common way to ground the cable's shield. Some special applications require shield breaks to limit circulating currents during the normal operations of the circuit. Circuits with shield breaks could be single or multi point grounded. Special engineering situations may require cross bonding.
Liquid or gas filled cables are still employed in distribution and transmission systems today. Cables of 10 kV or higher may be insulated with oil and paper, and are run in a rigid steel pipe, semi-rigid aluminum or lead sheath. For higher voltages the oil may be kept under pressure to prevent formation of voids that would allow
partial discharge
In electrical engineering, partial discharge (PD) is a localized dielectric breakdown (DB) (which does not completely bridge the space between the two conductors) of a small portion of a solid or fluid electrical insulation (EI) system under hig ...
s within the cable insulation.
Liquid filled cables are known for extremely long service lives with little to no outages. Unfortunately, oil leaks into soil and bodies of water are of grave concern and maintaining a fleet of the needed pumping stations is a boon on the O+M budget of most power utilities. Pipe type cables are often converted to solid insulation circuit at the end of their service life despite a shorter expected service life.
Modern
high-voltage cable
A high-voltage cable (HV cable) is a cable used for electric power transmission at high voltage. A cable includes a conductor and insulation. Cables are considered to be fully insulated. This means that they have a fully rated insulation system t ...
s use polyethylene or other polymers, including
XLPE
Cross-linked polyethylene, commonly abbreviated PEX, XPE or XLPE, is a form of polyethylene with cross-links. It is used predominantly in building services pipework systems, hydronic radiant heating and cooling systems, domestic water piping, ins ...
for insulation. They require special techniques for jointing and terminating, see
High-voltage cable
A high-voltage cable (HV cable) is a cable used for electric power transmission at high voltage. A cable includes a conductor and insulation. Cables are considered to be fully insulated. This means that they have a fully rated insulation system t ...
.
Flexibility of cables (stranding class)
All electrical cables are somewhat flexible, allowing them to be shipped to installation sites wound on reels, drums or hand coils. Flexibility is an important factor in determining the appropriate stranding class of the cable as it directly affects the minimum bending radius. Power cables are generally stranding class A, B, or C. These classes allow for the cable to be trained into a final installed position where the cable will generally not be disturbed. Class A, B, and C offer more durability, especially when pulling cable, and are generally cheaper. Power utilities generally order Class B stranded wire for primary and secondary voltage applications. At times, a solid conductor medium voltage cable can be used when flexibility is not a concern but low cost and water blocking are prioritized.
Applications requiring a cable to be moved repeatedly, such as for portable equipment, more flexible cables called "cords" or "flex" are used (stranding class G-M). Flexible cords contain fine stranded conductors, rope lay or bunch stranded. They feature overall jackets with appropriate amounts of filler materials to improve their flexibility, trainability, and durability. Heavy duty flexible power cords such as those feeding a
mine face
In mining, the face is the surface where the mining work is advancing. In surface mining it is commonly called pit face, in underground mining
Mining is the extraction of valuable minerals or other geological materials from the Earth, usua ...
cutting machine
Cutting is the separation or opening of a physical object, into two or more portions, through the application of an acutely directed force.
Implements commonly used for cutting are the knife and saw, or in medicine and science the scalpel and m ...
are carefully engineered — their life is measured in weeks. Very flexible power cables are used in automated machinery,
robotics
Robotics is an interdisciplinary branch of computer science and engineering. Robotics involves design, construction, operation, and use of robots. The goal of robotics is to design machines that can help and assist humans. Robotics integrat ...
, and machine tools. See
power cord
A power cord, line cord, or mains cable is an electrical cable that temporarily connects an appliance to the mains electricity supply via a wall socket or extension cord. The terms are generally used for cables using a power plug to connect t ...
and
extension cable for further description of flexible power cables. Other types of flexible cable include
twisted pair
Twisted pair cabling is a type of wiring used for communications in which two conductors of a single circuit are twisted together for the purposes of improving electromagnetic compatibility. Compared to a single conductor or an untwisted ba ...
, extensible,
coaxial
In geometry, coaxial means that several three-dimensional linear or planar forms share a common axis. The two-dimensional analog is ''concentric''.
Common examples:
A coaxial cable is a three-dimensional linear structure. It has a wire conduc ...
,
shielded, and communication cable.
An X-ray cable is a special type of flexible
high-voltage cable
A high-voltage cable (HV cable) is a cable used for electric power transmission at high voltage. A cable includes a conductor and insulation. Cables are considered to be fully insulated. This means that they have a fully rated insulation system t ...
.
See also
*
AC power plugs and sockets
AC power plugs and sockets connect electric equipment to the alternating current (AC) mains electricity power supply in buildings and at other sites. Electrical plugs and sockets differ from one another in voltage and current rating, shape, si ...
*
American wire gauge – for a table of cross section sizes
*
Ampacity – for a description of current carrying capacity of wires and cables
*
Cross-linked polyethylene
Cross-linked polyethylene, commonly abbreviated PEX, XPE or XLPE, is a form of polyethylene with cross-links. It is used predominantly in building services pipework systems, hydronic radiant heating and cooling systems, domestic water piping, ins ...
*
Electrical cable
An electrical cable is an assembly of one or more wires running side by side or bundled, which is used to carry electric current.
One or more electrical cables and their corresponding connectors may be formed into a ''cable assembly'', which ...
*
Ethylene propylene rubber
Ethylene propylene rubber (EPR, sometimes called EPM referring to an ASTM standard) is a type of synthetic elastomer that is closely related to EPDM rubber. Since introduction in the 1960s, annual production has increased to 870,000 metric tons. ...
(EPR)
*
Industrial and multiphase power plugs and sockets
Industrial and multiphase plugs and sockets provide a connection to the electrical mains rated at higher voltages and currents than household plugs and sockets. They are generally used in polyphase systems, with high currents, or when protection f ...
*
Overhead power line
An overhead power line is a structure used in electric power transmission and distribution to transmit electrical energy across large distances. It consists of one or more uninsulated electrical cables (commonly multiples of three for three-p ...
*
Portable cord
A portable cord (also known as portable cordage, flexible cord, or extension cord) is a cable with multiple conductors used for temporary electrical power connections requiring flexibility. The cord can be employed in a range of applications, s ...
*
Railway electrification system
A railway electrification system supplies electric power to railway trains and trams without an on-board prime mover or local fuel supply.
Electric railways use either electric locomotives (hauling passengers or freight in separate cars), ele ...
*
Restriction of Hazardous Substances Directive
The Restriction of Hazardous Substances Directive 2002/95/EC (RoHS 1), short for Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment, was adopted in February 2003 by the European Unio ...
*
Voltage drop
Voltage drop is the decrease of electrical potential along the path of a current flowing in an electrical circuit. Voltage drops in the internal resistance of the source, across conductors, across contacts, and across connectors are undesirable ...
– another consideration when selecting proper cable sizes
References