Photovoltaic System Performance
   HOME

TheInfoList



OR:

Photovoltaic system performance is a function of the climatic conditions, the equipment used and the system configuration. PV performance can be measured as the ratio of actual solar PV system output vs expected values, the measurement being essential for proper solar PV facility's operation and maintenance. The primary energy input is the global light irradiance in the plane of the solar arrays, and this in turn is a combination of the direct and the diffuse radiation. The performance is measured by PV monitoring systems, which include a data logging device and often also a weather measurement device (on-site device or an independent weather data source).
Photovoltaic Photovoltaics (PV) is the conversion of light into electricity using semiconducting materials that exhibit the photovoltaic effect, a phenomenon studied in physics, photochemistry, and electrochemistry. The photovoltaic effect is commercially us ...
performance monitoring systems serve several purposes - they are used to track trends in a single photovoltaic (PV) system, to identify faults in or damage to
solar panel A solar cell panel, solar electric panel, photo-voltaic (PV) module, PV panel or solar panel is an assembly of photovoltaic solar cells mounted in a (usually rectangular) frame, and a neatly organised collection of PV panels is called a photo ...
s and inverters, to compare the performance of a system to design specifications or to compare PV systems at different locations. This range of applications requires various sensors and monitoring systems, adapted to the intended purpose. Specifically, there is a need for both electronic monitoring sensors and independent weather sensing (irradiance, temperature and more) in order to normalize PV facility output expectations. Irradiance sensing is very important for the PV industry and can be classified into two main categories - on-site pyranometers and satellite remote sensing; when onsite pyranometers are not available, regional weather stations are also sometimes utilized, but at lower quality of data; the Industrial IoT-powered sensorless measurement approach has recently evolved as the third option. Sensors and photovoltaic monitoring systems are standardized in IEC 61724-1 and classified into three levels of accuracy, denoted by the letters “A”, “B” or “C”, or by the labels “High accuracy”, “Medium accuracy” and “Basic accuracy”. A parameter called the 'performance ratio' has been developed to evaluate the total value of PV system losses.


Overview

Photovoltaic system performance is generally dependent on incident
irradiance In radiometry, irradiance is the radiant flux ''received'' by a ''surface'' per unit area. The SI unit of irradiance is the watt per square metre (W⋅m−2). The CGS unit erg per square centimetre per second (erg⋅cm−2⋅s−1) is often used ...
in the plane of the
solar panels A solar cell panel, solar electric panel, photo-voltaic (PV) module, PV panel or solar panel is an assembly of photovoltaic solar cells mounted in a (usually rectangular) frame, and a neatly organised collection of PV panels is called a phot ...
, the temperature of the
solar cells A solar cell, or photovoltaic cell, is an electronic device that converts the energy of light directly into electricity by the photovoltaic effect, which is a physics, physical and Chemical substance, chemical phenomenon.spectrum A spectrum (plural ''spectra'' or ''spectrums'') is a condition that is not limited to a specific set of values but can vary, without gaps, across a continuum. The word was first used scientifically in optics to describe the rainbow of colors i ...
of the incident light. Furthermore, it is dependent upon the inverter, which typically sets the operating voltage of the system. The voltage and current output of the system changes as lighting, temperature and load conditions change, so there is no specific voltage, current, or wattage at which the system always operates. Hence, system performance varies depending on the time of day, amount of solar
insolation Solar irradiance is the power per unit area (surface power density) received from the Sun in the form of electromagnetic radiation in the wavelength range of the measuring instrument. Solar irradiance is measured in watts per square metre (W/m ...
, direction and tilt of modules, cloud cover, shading, soiling, state of charge, temperature, geographic location, and day of the year.


Performance by system type


Solar PV parks

Solar parks of industrial and utility scale may reach high performance figures. In modern solar parks the performance ratio should typically be in excess of 80%. Many solar PV parks utilize advanced performance monitoring solutions, which are supplied by a variety of technology providers.


Distributed solar PV

In rooftop solar systems it typically takes a longer time to identify a malfunction and send a technician, due to lower availability of sufficient photovoltaic system performance monitoring tools and higher costs of human labor. As a result, rooftop solar PV systems typically suffer from lower quality of operation & maintenance and essentially lower levels of system availability and energy output.


Off-grid solar PV

Most off-grid solar PV facilities lack any performance monitoring tools, due to a number of reasons - including monitoring equipment costs, cloud connection availability and O&M availability.


Performance monitoring

A number of technical solutions exist to provide performance monitoring for solar photovoltaic installations, differing according to data quality, compatibility with irradiance sensors as well as pricing. In general, monitoring solutions can be classified to inverter manufacturer-provided logger and monitoring software solutions, independent data-logger solutions with custom software and finally agnostic monitoring software-only solutions compatible with different inverters and data-loggers.


Monitoring solutions by inverter manufacturers

Dedicated performance monitoring systems are available from a number of vendors. For solar PV systems that use
microinverters A solar inverter or photovoltaic (PV) inverter is a type of power inverter which converts the variable direct current (DC) output of a photovoltaic solar panel into a utility frequency alternating current (AC) that can be fed into a commercial ...
(panel-level DC to AC conversion), module power data is automatically provided. Some systems allow setting performance alerts that trigger phone/email/text warnings when limits are reached. These solutions provide data for the system owner and/or the installer. Installers are able to remotely monitor multiple installations, and see at-a-glance the status of their entire installed base. All the major inverter manufacturers provide a data acquisition unit - whether a data logger or a direct means of communication with the portal. These solutions have the advantage of providing of a maximum information from the inverter and of supplying it on a local display or transmitting it on the internet, in particular alerts from the inverter itself (temperature overload, loss of connection with a network, etc.). Some of those monitoring solutions are: * Fronius accessible vi
Solar.web
portal; * SMA's Webbox/Inverter Manager/Cluster-Controller loggers accessible vi
Sunnyportal
an
EnnexOS
portals; * SolarEdge accessible vi
SolarEdge Monitoring
an
MySolarEdge
(only application) portals; * Sungrow accessible via th
iSolarCloud
portal;


Independent data logging solutions connected to inverters

Generic data logging solutions connected to inverters make it possible to overcome the major drawback of inverter-specific manufacturer solutions - being compatible with several different manufacturers. These data acquisition units connect to the serial links of the inverters, complying with each manufacturer’s protocol. Generic data logging solutions are generally more affordable than inverter manufacturer solutions and allow aggregation of solar PV system fleets of varying inverter manufacturers. Some of those monitoring solutions are: * AlsoEnergy loggers accessible via th
PowerTrack
portal; * Solar-Log loggers accessible via th

portal; * Meteocontrol loggers accessible via th
VCOM Cloud
portal; * Solar Analytics' "Smart Solar logger"s accessible via th
Solar Analytics
portal;


Independent monitoring solutions

The last category is the most recent segment in the solar photovoltaic monitoring domain. Those are software based aggregation portals, able to aggregate information from both inverter-specific portals and data loggers as well as independent data loggers. Such solutions become more widespread as inverter-specific communication to the cloud is done more and more without data loggers, but rather as direct data connections. * Omnidian residential solar performance insurance partne
Omnidian
* Soltell solar management solution for distributed solar PV, accessible vi
SysMap
portal; * Solytic generic solar monitorin
Solytic
portal; * Sunreport device-agnostic cloud solar monitorin
Sunreport
platform;


Energy generation data availability and quality

An essential part of PV system performance evaluation is the availability and the quality of energy generation data. Access to the Internet has allowed a further improvement in energy monitoring and communication. Typically, PV plant data is transmitted via a
data logger A data logger (also datalogger or data recorder) is an electronic device that records data over time or about location either with a built-in instrument or sensor or via external instruments and sensors. Increasingly, but not entirely, they a ...
to a central monitoring portal. Data transmission is dependent on the local cloud connectivity, thus being highly available in OECD countries, but more limited in developed countries. According to Samuel Zhang, vice president of Huawei Smart PV, over 90% of global PV plants will be fully digitilized by 2025.


Weather data sources


On-site irradiance sensors

On-site irradiance measurements are an important part of PV performance monitoring systems. Irradiance can be measured in the same orientation as the PV panels, so-called plane of array (POA) measurements, or horizontally, so-called global horizontal irradiance (GHI) measurements. Typical sensors used for such irradiance measurements include thermopile pyranometers, PV reference devices and
photodiode A photodiode is a light-sensitive semiconductor diode. It produces current when it absorbs photons. The package of a photodiode allows light (or infrared or ultraviolet radiation, or X-rays) to reach the sensitive part of the device. The packag ...
sensors. To conform to a specific accuracy class, each sensor type must meet a certain set of specifications. These specifications are listed in the table below. If an irradiance sensor is placed in POA, it must be placed at the same tilt angle as the PV module, either by attaching it to the module itself or with an extra platform or arm at the same tilt level. Checking if the sensor is properly aligned can be done with portable tilt sensors or with an integrated tilt sensor.


Sensor maintenance

The standard also specifies a required maintenance schedule per accuracy class. Class C sensors require maintenance per manufacturer's requirement. Class B sensors need to be re-calibrated every 2 years and require a heater to prevent precipitation or condensation. Class A sensors need to be re-calibrated once per year, require cleaning once per week, require a heater and require ventilation (for thermopile pyranometers).


Satellite remote sensing of irradiance

PV performance can also be estimated by satellite
remote sensing Remote sensing is the acquisition of information about an object or phenomenon without making physical contact with the object, in contrast to in situ or on-site observation. The term is applied especially to acquiring information about Earth ...
. These measurements are indirect because the satellites measure the solar radiance reflected off the earth surface. In addition, the radiance is filtered by the spectral
absorption Absorption may refer to: Chemistry and biology * Absorption (biology), digestion **Absorption (small intestine) *Absorption (chemistry), diffusion of particles of gas or liquid into liquid or solid materials *Absorption (skin), a route by which ...
of
Earth's atmosphere The atmosphere of Earth is the layer of gases, known collectively as air, retained by Earth's gravity that surrounds the planet and forms its planetary atmosphere. The atmosphere of Earth protects life on Earth by creating pressure allowing for ...
. This method is typically used in non-instrumented class B and class C monitoring systems to avoid costs and maintenance of on-site sensors. If the satellite-derived data is not corrected for local conditions, an error in radiance up to 10% is possible.


Equipment and performance standards

Sensors and monitoring systems are standardized in IEC 61724-1 and classified into three levels of accuracy, denoted by the letters “A”, “B” or “C”, or by the labels “High accuracy”, “Medium accuracy” and “Basic accuracy”. In California, solar PV performance monitoring has been regulated by the State government. As of 2017, the governmental agency California Solar Initiative (CSI) provided a Performance Monitoring & Reporting Service certificate to eligible companies active in the solar segment and acting in line with CSI requirements.https://www.energy.ca.gov/sites/default/files/2020-06/PMRS_Certification.pdf A parameter called the 'performance ratio' has been developed to evaluate the total value of PV system losses. The performance ratio gives a measure of the output AC power delivered as a proportion of the total DC power which the solar modules should be able to deliver under the ambient climatic conditions.


See also

*
Photovoltaics Photovoltaics (PV) is the conversion of light into electricity using semiconducting materials that exhibit the photovoltaic effect, a phenomenon studied in physics, photochemistry, and electrochemistry. The photovoltaic effect is commercially us ...
* Pyranometer *
Remote sensing Remote sensing is the acquisition of information about an object or phenomenon without making physical contact with the object, in contrast to in situ or on-site observation. The term is applied especially to acquiring information about Earth ...
* Atmosphere of Earth *
Absorption (electromagnetic radiation) In physics, absorption of electromagnetic radiation is how matter (typically electrons bound in atoms) takes up a photon's energy — and so transforms electromagnetic energy into internal energy of the absorber (for example, thermal energy). ...


References


External links


NREL - Analytics of PV System Energy Performance Evaluation Method
{{Photovoltaics Photovoltaics Maintenance