"Passive house" (german: Passivhaus) is a voluntary standard for energy efficiency in a building, which reduces the building's
ecological footprint The ecological footprint is a method promoted by the Global Footprint Network to measure human demand on natural capital, i.e. the quantity of nature it takes to support people or an economy. It tracks this demand through an ecological accounti ...
. It results in ultra-low energy buildings that require little energy for space heating or cooling. A similar standard, MINERGIE-P, is used in
Switzerland ). Swiss law does not designate a ''capital'' as such, but the federal parliament and government are installed in Bern, while other federal institutions, such as the federal courts, are in other cities (Bellinzona, Lausanne, Luzern, Neuchâtel ...
. The standard is not confined to residential properties; several office buildings, schools, kindergartens and a
supermarket A supermarket is a self-service Retail#Types of outlets, shop offering a wide variety of food, Drink, beverages and Household goods, household products, organized into sections. This kind of store is larger and has a wider selection than earli ...
have also been constructed to the standard. The design is not an attachment or supplement to architectural design, but a design process that integrates with architectural design. Although it is generally applied to new buildings, it has also been used for refurbishments. In 2008, estimates of the number of passive house buildings around the world ranged from 15,000 to 20,000 structures. In 2016, there were approximately 60,000 such certified structures of all types worldwide. The vast majority of passive structures have been built in German-speaking countries and Scandinavia.


History

The ''passivhaus'' standard originated from a conversation in May 1988 between Bo Adamson of Lund University, in
Sweden Sweden, formally the Kingdom of Sweden,The United Nations Group of Experts on Geographical Names states that the country's formal name is the Kingdom of SwedenUNGEGN World Geographical Names, Sweden./ref> is a Nordic country located on ...
, and Wolfgang Feist of the ''Institut für Wohnen und Umwelt'' (Institute for Housing and the Environment), in Darmstadt, Germany. Later, their concept was further developed through a number of research projects, aided by financial assistance from the German state of Hessen. Much of the early "passive houses" builds were based on research and the experience of North American builders during the 1970s, who – in response to the oil embargo – sought to build homes that used very little to no energy. These designs often utilized expansive solar-gain windows, which used the sun as a heat source. However,
superinsulation Superinsulation is an approach to building design, construction, and retrofitting that dramatically reduces heat loss (and gain) by using much higher levels of insulation and airtightness than normal. Superinsulation is one of the ancestors of t ...
prevailed over, as seen in the Saskatchewan Conservation House (1977) and the Leger House in Pepperell, Massachusetts (1977). The Saskatchewan Conservation house was a project of the Saskatchewan Research Council (SRC), who independently developed a heat recovery air exchanger (HRV), hot water recovery, and a blower-door apparatus to measure building air-tightness — notably the house was designed for the extreme -40C to +40C climate of the Canadian prairie. The SRC and Leger houses were predated by the Lyngby, Denmark house (1975), developed by the Technical University of Denmark, and several homes were built between 1977 and 1979 based on the Lo-Cal house design (1976) developed by the University of Illinois at Urbana–Champaign. The name 'passive' can be partly attributed to William Shurcliff, an American physicist who contributed to the WWII Manhattan Project, and in the 1970s became an advocate for energy-efficient home design:
''"What name should be given to this new system? Superinsulated passive? Super-save passive? Mini-need passive? Micro-load passive? I lean toward ‘micro-load passive.’ Whatever it is called, it has (I predict) a big future." - William Shurcliff, 1979''
An early book explaining the concepts of passive house construction was ''The Passive Solar Energy Book'' by Edward Mazria in 1979.


First examples

The eventual construction of four
row house In architecture and city planning, a terrace or terraced house (British English, UK) or townhouse (American English, US) is a form of medium-density housing that originated in Europe in the 16th century, whereby a row of attached dwellings party ...
s (terraced houses or town homes) were designed for four private clients by the
architectural firm In the United States, an architectural firm or architecture firm is a business that employs one or more licensed architects and practices the profession of architecture; while in South Africa, the United Kingdom, Ireland, Denmark and other countri ...
Bott, Ridder and Westermeyer. The first ''Passivhaus'' residences were built in
Darmstadt Darmstadt () is a city in the States of Germany, state of Hesse in Germany, located in the southern part of the Frankfurt Rhine Main Area, Rhine-Main-Area (Frankfurt Metropolitan Region). Darmstadt has around 160,000 inhabitants, making it th ...
in 1990, and occupied by the clients the following year.


Further implementation and councils

In September 1996, the Passivhaus-Institut was founded in Darmstadt to promote and control ''passivhaus'' standards. By 2010 more than 25,000 ''passivhaus'' structures were estimated to have been built. Most are located in Germany and Austria, others in various countries worldwide. In 1996, after the concept had been validated at the Institute in Darmstadt, with space heating at 90% less than that required for a standard new building at the time, the Economical Passive Houses Working Group was created. This group developed the planning package and initiated the production of the innovative components that had been used, notably the windows and the high-efficiency ventilation systems. Meanwhile, further passive houses were built in
Stuttgart Stuttgart (; Swabian: ; ) is the capital and largest city of the German state of Baden-Württemberg. It is located on the Neckar river in a fertile valley known as the ''Stuttgarter Kessel'' (Stuttgart Cauldron) and lies an hour from the ...
(1993), Naumburg, Hesse, Wiesbaden, and Cologne (1997). Products that had been developed according to the ''passivhaus'' standard were further commercialized during and following the European Union sponsored CEPHEUS project, which proved the concept in five European countries in the winter of 2000–2001. The first certified house was built in 2006 near Bemidji, Minnesota, in Camp Waldsee of the German Concordia Language Villages. The first US passive retrofit project, the remodeled craftsman O'Neill house in Sonoma, California, was certified in July 2010. In the United States, the concept of ''passivhaus'' design was first implemented by Katrin Klingenberg in 2003 when she built a passive home prototype named "The Smith House" in Urbana, Illinois. Consequently, she and builder Mike Kernagis co-founded the Ecological Construction Laboratory (E-Colab) in 2004 to further explore the feasibility of the affordable passive design. It eventually led to the inception of the Passive House Institute United States (PHIUS) in 2007. Afterwards, the PHIUS has released their PHIUS + 2015 Building Standard and has certified over 1,200 projects and across the United States. In 2019, Park Avenue Green, a low-income housing building in New York was built with ''passivhaus'' standard. The building later became the largest certified "passive house" in North America. Ireland's first "passive house" was built in 2005 by Tomas O'Leary, a "passive house" designer and teacher. The house was called 'Out of the Blue'. Upon completion, Tomas moved into the building. The world's first
standardised Standardization or standardisation is the process of implementing and developing technical standards based on the consensus of different parties that include firms, users, interest groups, standards organizations and governments. Standardization ...
passive prefabricated house was built in Ireland in 2005 by Scandinavian Homes a Swedish company, that has since built more passive houses in England and Poland. The first certified "passive house" in the
Antwerp Antwerp (; nl, Antwerpen ; french: Anvers ; es, Amberes) is the largest city in Belgium by area at and the capital of Antwerp Province in the Flemish Region. With a population of 520,504,
region of Belgium was built in 2010. In 2011, the city of Heidelberg in Germany initiated the Bahnstadt project, which was seen as the world's largest passive house building area. A company in Qatar planned the country's first Passive House in 2013, the first in the region. The world's tallest "passive house" was built in the Bolueta neighborhood in Bilbao, Spain. At , it is currently the world's tallest building certified under the standard in 2018. The $14.5 million, 171-unit development (including a nine-story companion to the high-rise) consists entirely of social housing.
Gaobeidian Gaobeidian () is a county-level city in central Hebei province, People's Republic of China. It is under the administration of Baoding Prefecture-level city. Gaobeidian has 4 subdistricts, 6 towns, and 4 townships, and a total of 442 villages. It ...
, China hosted the 23rd International Passive House Conference in 2019, and later built Gaobeidian Railway City apartment complex which is reported to be "the world's largest passive house project". China have taken a leadership role in passive house construction, with 73 different companies "making windows to the 'passive house' standards." The United Kingdom’s first ''passivhaus'' health centre, in Foleshill was opened in November 2021.


Standards

While some techniques and technologies were specifically developed for the "passive house" standard, others, such as
superinsulation Superinsulation is an approach to building design, construction, and retrofitting that dramatically reduces heat loss (and gain) by using much higher levels of insulation and airtightness than normal. Superinsulation is one of the ancestors of t ...
, already existed, and the concept of passive solar building design dates back to antiquity. There were other previous buildings with low-energy building standards, notably the German ''Niedrigenergiehaus'' (low-energy house) standard, in addition to buildings constructed to the demanding energy codes of Sweden and Denmark.


International Passivhaus Standard

The ''passivhaus'' standard requires that the building fulfills the following requirements: * Use up to of floor area per year for heating and cooling as calculated by the Passivhaus Planning Package, or a peak heat load of of floor area, based on local climate data. * Use up to of floor area per year primary energy (for heating,
hot water Water heating is a heat transfer process that uses an energy source to heat water above its initial temperature. Typical domestic uses of hot water include cooking, cleaning, bathing, and space heating. In industry, hot water and water heated t ...
and electricity). * Leak air up to 0.6 times the house volume per hour (''n''50 ≤ 0.6 / hour) at as tested by a blower door; or up to per square foot of the surface area of the enclosure.


Recommendations

The specific heat load for the heating source at design temperature is recommended, but not required, to be less than 10  W/m2 (3.17  btu/(h⋅ft2)). These standards are much higher than houses built to most normal building codes. For comparisons, see the international comparisons section below. National partners within the 'consortium for the Promotion of European Passive Houses' are thought to have some flexibility to adapt these limits locally.


Space heating requirement

If a building meets the ''passivhaus'' standards, it does not need conventional heating systems, though some heating will still be required and most ''passivhaus'' buildings include supplemental space heating. This is normally distributed through the low-volume heat recovery ventilation system that is required to maintain air quality, rather than by a conventional hydronic or high-volume forced-air heating system, as described in the space heating section below.


Passive House standards in the US - Passive House Standard and PHIUS+

In the US there are two versions of "passive house" being promoted by two separate entities: the Passive House Institute (PHI) and the Passive House Institute US (PHIUS). PHIUS was originally an affiliate and approved trainer and certifier for the Passive House Institute. In 2011, PHI cancelled its contract with PHIUS for misconduct. PHIUS disputed the claims by PHI and continued working to launch an independent building performance program. In 2015 PHIUS launched its own "PHIUS+" standard. The PHIUS + 2015 Standard primarily focuses on reducing negative effects of building operations, for any type of building. This standard also uses climate data sets to determine specific building performance criteria for different regions. Such information is determined using metrics that represent a space where significant carbon and energy reduction overlap with cost-effectiveness. Overall, the PHIUS database includes more than 1000 climate data sets for North America. The Institute believes that this approach to the Standard is essential, as North America has variety of different climates and different passive measures may be more effective than others. The standard is based on five principles:
airtightness A hermetic seal is any type of sealing that makes a given object airtight (preventing the passage of air, oxygen, or other gases). The term originally applied to airtight glass containers, but as technology advanced it applied to a larger categor ...
, ventilation, waterproofing, heating and cooling, and electrical loads. Within these principles, projects must pass building specified blower door, ventilation airflow, overall airflow, and electrical load tests; buildings must also achieve other measures such as low-emission materials, renewable energy systems, moisture control, outdoor ventilation, and energy efficient ventilation and space conditioning equipment. All buildings must also pass a
quality assurance Quality assurance (QA) is the term used in both manufacturing and service industries to describe the systematic efforts taken to ensure that the product(s) delivered to customer(s) meet with the contractual and other agreed upon performance, design ...
and
quality control Quality control (QC) is a process by which entities review the quality of all factors involved in production. ISO 9000 defines quality control as "a part of quality management focused on fulfilling quality requirements". This approach places ...
test – this is implemented to ensure that the building continues to adhere to the regional criteria set forth by the PHIUS’ climate data. These tests and analyses of operative conditions are performed by PHIUS raters or verifiers. These are accredited professionals from the PHIUS that are able to perform on-site testing and inspections to ensure that the newly constructed building is adhering to the construction plans, created energy models, and desired operating conditions. The two standards ("passive house" and PHIUS+) are distinct and target different performance metrics and use different energy modeling software and protocols. In the US, the International Passive House Standard is supported by the North American Passive House Network (NAPHN) and its chapters, as well as by independent affiliates such as Passive House California and New York Passive House.


Construction costs

In ''passivhaus'' buildings, the cost savings from dispensing with the conventional heating system can be used to fund the upgrade of the building envelope and the heat recovery ventilation system. With careful design and increasing competition in the supply of the specifically designed ''passivhaus'' building products, in Germany it is currently possible to construct buildings for the same cost as those built to normal German building standards, as was done with the ''passivhaus'' apartments at Vauban, Freiburg. On average passive houses are reported to be more expensive upfront than conventional buildings – 5% to 8% in Germany, 8% to 10% in UK and 5% to 10% in USA. Evaluations have indicated that while it is technically possible, the costs of meeting the ''passivhaus'' standard increase significantly when building in
Northern Europe The northern region of Europe has several definitions. A restrictive definition may describe Northern Europe as being roughly north of the southern coast of the Baltic Sea, which is about 54th parallel north, 54°N, or may be based on other g ...
above 60° latitude. European cities at approximately 60° include Helsinki in Finland and Bergen in Norway. London is at 51°; Moscow is at 55°.


Design and construction

Achieving the major decrease in heating energy consumption required by the standard involves a shift in approach to building design and construction. Design may be assisted by use of the 'Passivhaus Planning Package' (PHPP), which uses specifically designed
computer simulation Computer simulation is the process of mathematical modelling, performed on a computer, which is designed to predict the behaviour of, or the outcome of, a real-world or physical system. The reliability of some mathematical models can be dete ...
s. Below are the techniques used to achieve the standard.


Passive solar design and landscape

Passive solar building design and energy-efficient landscaping support the passive house energy conservation and can integrate them into a
neighborhood A neighbourhood (British English, Irish English, Australian English and Canadian English) or neighborhood (American English; see spelling differences) is a geographically localised community within a larger city, town, suburb or rural area, ...
and environment. Following passive solar building techniques, where possible buildings are compact in shape to reduce their surface area, with principal windows oriented towards the equator – south in the northern hemisphere and north in the southern hemisphere – to maximize passive solar gain. However, the use of solar gain, especially in temperate climate regions, is secondary to minimizing the overall house energy requirements. In climates and regions needing to reduce excessive summer passive solar heat gain, whether from direct or reflected sources, ''
brise soleil ''Brise soleil'', sometimes ''brise-soleil'' (; ), is an architectural feature of a building that reduces heat gain within that building by deflecting sunlight. More recently, vertical Brise soleil have become popular. Both systems allow low-l ...
'', trees, attached ''
pergola A pergola is most commonly an outdoor garden feature forming a shaded walkway, passageway, or sitting area of vertical posts or pillars that usually support cross-beams and a sturdy open lattice, often upon which woody vines are trained. The ...
s'' with vines, vertical gardens, green roofs, and other techniques are implemented. Exterior wall color, when the surface allows choice, for reflection or absorption
insolation Solar irradiance is the power per unit area (surface power density) received from the Sun in the form of electromagnetic radiation in the wavelength range of the measuring instrument. Solar irradiance is measured in watts per square metre (W/m ...
qualities depends on the predominant year-round ambient outdoor temperature. The use of deciduous trees and wall trellised or self attaching vines can assist in climates not at the temperature extremes.


Superinsulation

''Passivhaus'' buildings employ
superinsulation Superinsulation is an approach to building design, construction, and retrofitting that dramatically reduces heat loss (and gain) by using much higher levels of insulation and airtightness than normal. Superinsulation is one of the ancestors of t ...
to significantly reduce the heat transfer through the walls, roof and floor compared to conventional buildings. A wide range of thermal insulation materials can be used to provide the required high R-values (low U-values, typically in the 0.10 to 0.15 W/(m2·K) range). Special attention is given to eliminating thermal bridges. A disadvantage resulting from the thickness of wall insulation required is that, unless the external dimensions of the building can be enlarged to compensate, the internal floor area of the building may be less compared to traditional construction. In Sweden, to achieve passive house standards, the insulation thickness would be (0.10 W/(m2·K)) and the roof (U-value 0.066 W/(m2·K)).


Advanced window technology

To meet the requirements of the ''passivhaus'' standard, windows are manufactured with exceptionally high R-values (low U-values, typically 0.85 to 0.45 W/(m2·K) for the entire window including the frame). The windows normally combine triple or quadruple-pane insulated glazing (with an appropriate solar heat-gain coefficient, low-emissivity coatings,
sealed Seal may refer to any of the following: Common uses * Pinniped, a diverse group of semi-aquatic marine mammals, many of which are commonly called seals, particularly: ** Earless seal, or "true seal" ** Fur seal * Seal (emblem), a device to impr ...
argon or krypton gas filled inter-pane voids, and 'warm edge' insulating glass spacers) with air-seals and specially developed thermal break window frames. In Central Europe and most of the United States, for unobstructed south-facing ''passivhaus'' windows, the heat gains from the sun are, on average, greater than the heat losses, even in mid-winter.


Airtightness

Building envelopes under the ''passivhaus'' standard are required to be extremely airtight compared to conventional construction. They are required to meet either 0.60 ACH50 (air changes per hour at 50 pascals) based on the building's volume, or 0.05 CFM50/sf (cubic feet per minute at 50 pascals, per square foot of building enclosure surface area). In order to achieve these metrics, recommended best practice is to test the building air barrier enclosure with a blower door at mid-construction if possible. "Passive house" is designed so that most of the air exchange with exterior is done by controlled ventilation through a heat-exchanger in order to minimize heat loss (or gain, depending on climate), so uncontrolled air leaks are best avoided. Another reason is the passive house standard makes extensive use of insulation which usually requires a careful management of moisture and dew points. This is achieved through air barriers, careful sealing of every construction joint in the building envelope, and sealing of all service penetrations.


Ventilation

Use of passive natural ventilation is an integral component of passive house design where ambient temperature is conducive — either by singular or cross ventilation, by a simple opening or enhanced by the
stack effect The stack effect or chimney effect is the movement of air into and out of buildings through unsealed openings, chimneys, flue-gas stacks, or other containers, resulting from air buoyancy. Buoyancy occurs due to a difference in indoor-to-outdoor a ...
from smaller ingress with larger egress windows and/or
clerestory In architecture, a clerestory ( ; , also clearstory, clearstorey, or overstorey) is a high section of wall that contains windows above eye level. Its purpose is to admit light, fresh air, or both. Historically, ''clerestory'' denoted an upper l ...
-operable
skylight A skylight (sometimes called a rooflight) is a light-permitting structure or window, usually made of transparent or translucent glass, that forms all or part of the roof space of a building for daylighting and ventilation purposes. History Open ...
. When ambient climate is not conducive, mechanical heat recovery ventilation systems, with a heat recovery rate of over 80% and high-efficiency electronically commutated motors (ECM), are employed to maintain air quality, and to recover sufficient heat to dispense with a conventional central heating system. Since passively designed buildings are essentially air-tight, the rate of air change can be optimized and carefully controlled at about 0.4 air changes per hour. All ventilation ducts are insulated and sealed against leakage. Some ''passivhaus'' builders promote the use of earth warming tubes. The tubes are typically around in diameter, long at a depth of about . They are buried in the soil to act as earth-to-air heat exchangers and pre-heat (or pre-cool) the intake air for the ventilation system. In cold weather, the warmed air also prevents ice formation in the heat recovery system's heat exchanger. Concerns about this technique have arisen in some climates due to problems with condensation and mold. Alternatively, an earth to air heat exchanger can use a liquid circuit instead of an air circuit, with a heat exchanger (battery) on the supply air.


Space heating

In addition to using passive solar gain, ''passivhaus'' buildings make extensive use of their intrinsic heat from internal sources—such as waste heat from lighting, white goods (major appliances) and other electrical devices (but not dedicated heaters)—as well as body heat from the people and other animals inside the building. This is due to the fact that people, on average, emit heat equivalent to 100 watts each of radiated thermal energy. Together with the comprehensive
energy conservation Energy conservation is the effort to reduce wasteful energy consumption by using fewer energy services. This can be done by using energy more effectively (using less energy for continuous service) or changing one's behavior to use less service (f ...
measures taken, this means that a conventional central heating system is not necessary, although they are sometimes installed due to client's skepticism.Zeller, 2010. p.BU1. Example: in the case of the Landau home described in the NYT's article, several insurance companies refused to insure their home when they were told there was no home furnace in the structure, fearing that they would be held financially liable for frozen water pipe damage. Instead, "passive houses" sometimes have a dual purpose 800 to 1,500 watt heating and/or cooling element integrated with the supply air duct of the ventilation system, for use during the coldest days. It is fundamental to the design that all the heat required can be transported by the normal low air volume required for ventilation. A maximum air temperature of is applied, to prevent any possible smell of scorching from dust that escapes the filters in the system. The air-heating element can be heated by a small heat pump, by direct solar thermal energy, annualized geothermal solar, or simply by a natural gas or oil burner. In some cases a micro-heat pump is used to extract additional heat from the exhaust ventilation air, using it to heat either the incoming air or the hot water storage tank. Small wood-burning stoves can also be used to heat the water tank, although care is required to ensure that the room in which stove is located does not overheat. Beyond the recovery of heat by the heat recovery ventilation unit, a well designed Passive house in the European climate should not need any supplemental heat source if the heating load is kept under 10 W/m2. Because the heating capacity and the heating energy required by a passive house both are very low, the particular energy source selected has fewer financial implications than in a traditional building, although
renewable energy Renewable energy is energy that is collected from renewable resources that are naturally replenished on a human timescale. It includes sources such as sunlight, wind, the movement of water, and geothermal heat. Although most renewable energy ...
sources are well suited to such low loads. The "passive house" standards in Europe set a space heating and cooling energy demand of per year, and peak demand. In addition, the total energy to be used in the building operations including heating, cooling, lighting, equipment, hot water, plug loads, etc. is limited to of treated floor area per year.


Lighting and electrical appliances

To minimize the total primary energy consumption, the many passive and
active daylighting Daylighting is the practice of placing windows, skylights, other openings, and reflective surfaces so that sunlight (direct or indirect) can provide effective internal lighting. Particular attention is given to daylighting while designing a b ...
techniques are the first daytime solution to employ. For low-light days, non-daylighted spaces, and nighttime, the use of creative-sustainable lighting design using low-energy sources can be used. Low-energy sources include 'standard voltage' compact fluorescent lamps, solid-state lighting with LED lamps, organic light-emitting diodes, PLED – polymer light-emitting diodes, 'low voltage' electrical filament- Incandescent light bulbs, compact metal halide, xenon, and halogen lamps. Solar powered exterior circulation, security, and landscape lighting – with photovoltaic cells on each fixture or connecting to a central
Solar panel A solar cell panel, solar electric panel, photo-voltaic (PV) module, PV panel or solar panel is an assembly of photovoltaic solar cells mounted in a (usually rectangular) frame, and a neatly organised collection of PV panels is called a photo ...
system, are available for gardens and outdoor needs. Low voltage systems can be used for more controlled or independent illumination, while still using less electricity than conventional fixtures and lamps. Timers,
motion detection Motion detection is the process of detecting a change in the position of an object relative to its surroundings or a change in the surroundings relative to an object. It can be achieved by either mechanical or electronic methods. When it is done by ...
and natural light operation sensors reduce energy consumption, and light pollution even further for a ''passivhaus'' setting. Appliance consumer products meeting independent energy efficiency testing and receiving
Ecolabel Ecolabels (also "Eco-Labels") and Green Stickers are labeling systems for food and consumer products. The use of ecolabels is voluntary, whereas green stickers are mandated by law; for example, in North America major appliances and automobiles us ...
certification marks for reduced electrical-'natural-gas' consumption, as well as product manufacturing carbon emission labels are preferred for use in Passive houses. The eco-label certification marks of Energy Star and EKOenergy are examples.


Traits of passive houses

Typically, passive houses feature: * Fresh, clean air: Note that for the parameters tested, and provided the filters (minimum F6) are maintained, HEPA quality air is provided. 0.3 air changes per hour (ACH) are recommended, otherwise the air can become "stale" (excess CO2, flushing of indoor air pollutants) and any greater, excessively dry (less than 40% humidity). This implies careful selection of interior finishes and furnishings, to minimize indoor air pollution from VOC's (e.g., formaldehyde). This can be counteracted somewhat by opening a window for a very brief time, by plants, and by indoor fountains. * Because of the high resistance to heat flow (high R-value insulation), there are no "outside walls" which are colder than other walls. * Homogeneous interior temperature: it is impossible to have single rooms (e.g. the sleeping rooms) at a different temperature from the rest of the house. Note that the relatively high temperature of the sleeping areas is physiologically not considered desirable by some building scientists. Bedroom windows can be cracked open slightly to alleviate this when necessary. * Slow temperature changes: with ventilation and heating systems switched off, a passive house typically loses less than per day (in winter), stabilizing at around in the central European climate. * Quick return to normal temperature: opening windows or doors for a short time has only a limited effect; after apertures are closed, the air very quickly returns to the "normal" temperature. * Some have voiced concerns that ''passivhaus'' standard is not a general approach as the occupant has to behave in a prescribed way, for example not opening windows too often. However modelling shows that such concerns are not valid.


International comparisons

* In the United States, a house built to the ''passivhaus'' standard results in a building that requires space heating energy of per heating degree day, compared with about per heating degree day for a similar building built to meet the 2003 Model Energy Efficiency Code. This is between 75 and 95% less energy for space heating and cooling than current new buildings that meet today's US energy efficiency codes. The passive house in the German-language camp of Waldsee, Minnesota, was designed under the guidance of architect Stephan Tanner of INTEP, LLC, a Minneapolis- and Munich-based consulting company for high performance and sustainable construction. Waldsee BioHaus is modeled on Germany's ''passivhaus'' standard, when compared to houses of the U.S. LEED standard, shows improvement to the quality of life inside the building while using 85% less energy than a house built to the latter standard. VOLKsHouse 1.0 was the first certified "passive house" offered and sold in Santa Fe New Mexico. * In the United Kingdom, an average new house built with the "passive house" standard would use 77% less energy for space heating, compared to the house built under circa-2006 Building Regulations. * In Ireland, a typical house built to the "passive house" standard instead of the 2002 Building Regulations would consume 85% less energy for space heating and cut space-heating related
carbon emissions Greenhouse gas emissions from human activities strengthen the greenhouse effect, contributing to climate change. Most is carbon dioxide from burning fossil fuels: coal, oil, and natural gas. The largest emitters include coal in China and larg ...
by 94%.


Comparison with zero energy buildings

A net zero-energy building (ZEB) is a building that over a year does not use more energy than it generates. The first 1979 Zero Energy Design building used passive solar heating and cooling techniques with airtight construction and super insulation. A few ZEBs fail to fully exploit more affordable conservation technology and all use onsite active
renewable energy Renewable energy is energy that is collected from renewable resources that are naturally replenished on a human timescale. It includes sources such as sunlight, wind, the movement of water, and geothermal heat. Although most renewable energy ...
technologies like
photovoltaic Photovoltaics (PV) is the conversion of light into electricity using semiconducting materials that exhibit the photovoltaic effect, a phenomenon studied in physics, photochemistry, and electrochemistry. The photovoltaic effect is commercially us ...
to offset the building's primary energy consumption. "Passive house" and ZEB are regarded as complementary synergistic technology approaches, based on the same physics of thermal energy transfer and storage: ZEBs drive the annual energy consumption down to 0 kWh/m2 with help from on-site renewable energy sources and can benefit from materials and methods which are used to meet the passive house demand constraint of 120 kWh/m2 which will minimize the need for the often costly on-site renewable energy sources. Energy Plus houses are similar to both ''passivhaus'' and ZEB but emphasize the production of more energy per year than they consume, e.g., annual energy performance of −25 kWh/m2 is an Energy Plus house.


Comparison to the Zero heating building

With advances in ultra low U-value glazing, a "passive house" based (nearly) zero heating building is proposed to supersede nearly-zero energy buildings in EU. The zero heating building reduces on the passive solar design and makes the building more opened to conventional architectural design. The annual specific heat demand for the zero-heating house should not exceed 3 kWh/m2a. Zero heating building is generally considered to be simpler to design and to operate as there is no need for modulated sun shading.


Tropical climate needs

In a tropical climate, ''passivhaus'' standard have proven to be helpful for ideal internal conditions by using energy recovery ventilation instead of heat recovery ventilation to reduce the humidity load of ventilation on the mechanical dehumidification system. Although dehumidifiers might be used, heat pump hot water heaters also will act to cool and condense interior humidity (where it can be dumped into drains) and dump the heat into the hot water tank.
Passive cooling Passive cooling is a building design approach that focuses on heat gain control and heat dissipation in a building in order to improve the indoor thermal comfort with low or no energy consumption. This approach works either by preventing heat from ...
, solar air conditioning, and other solutions in passive solar building design have been studied to adapt the "passive house" concept for use in more regions of the world. A certified "passive house" was built in the hot and humid climate of Lafayette, Louisiana, USA. It uses energy recovery ventilation and an efficient one ton air-conditioner to provide cooling and dehumidification.
Solar access Solar access is the ability of one property to continue to receive sunlight across property lines without obstruction from another’s property (buildings, foliage or other impediment). Solar access is calculated using a sun path diagram. Sun is t ...
have been a very important factor in any design of a passive house as it allows the structure to use the solar energy to heat and light the space naturally, and to replace electrical water heaters with solar energy-based water heaters.


See also

* EnerGuide (Canada) * Energy-plus-house * Green building * History of passive solar building design * Home energy rating (USA) * House Energy Rating (Aust.) * List of low-energy building techniques * List of pioneering solar buildings *
Low-energy house A low-energy house is characterized by an energy-efficient design and technical features which enable it to provide high living standards and comfort with low energy consumption and carbon emissions. Traditional heating and active cooling systems ...
* National Home Energy Rating (UK) * Passive daytime radiative cooling * Passive solar * Quadruple glazing * R-2000 program (Canada) * Renewable heat * Self-sufficient homes *
Solar air heat Solar air heating is a solar thermal technology in which the energy from the sun, insolation, is captured by an absorbing medium and used to heat air. Solar air heating is a renewable energy heating technology used to heat or condition air for buil ...
*
Sustainable refurbishment Sustainable refurbishment describes working on existing buildings to improve their environmental performance using sustainable methods and materials. A refurbishment or retrofit is defined as: “any work to a building over and above maintenance to ...
* Zero heating building


References


Further reading

* * * *


External links


Passive House Institute (PHI)
(in English)
International Passive House Association (iPHA)

Passipedia
- The Passive House Resource
North American Passive House Network

Canadian Passive House Institute (CanPHI)



European Passive Houses

Passive House Alliance United States

Passive House California

New York Passive House

Passive House Institute New Zealand

Passive House Institute Australia

Passivhaus Germany

Passive house Illawarra

Passive house Accelerator
{{Authority control Energy conservation in Germany House types Low-energy building Sustainable building