In
science and
engineering, the parts-per notation is a set of pseudo-units to describe small values of miscellaneous
dimensionless quantities, e.g.
mole fraction or
mass fraction. Since these
fractions are quantity-per-quantity measures, they are pure numbers with no associated
units of measurement. Commonly used are parts-per-million (ppm, ), parts-per-billion (ppb, ), parts-per-trillion (ppt, ) and parts-per-quadrillion (ppq, ). This notation is not part of the
International System of Units
The International System of Units, known by the international abbreviation SI in all languages and sometimes pleonastically as the SI system, is the modern form of the metric system and the world's most widely used system of measurement. E ...
(SI) system and its meaning is ambiguous.
Overview
Parts-per notation is often used describing dilute solutions in
chemistry
Chemistry is the science, scientific study of the properties and behavior of matter. It is a natural science that covers the Chemical element, elements that make up matter to the chemical compound, compounds made of atoms, molecules and ions ...
, for instance, the relative abundance of dissolved minerals or pollutants in
water. The quantity "1 ppm" can be used for a mass fraction if a water-borne pollutant is present at one-millionth of a
gram per gram of sample solution. When working with
aqueous solution
An aqueous solution is a solution in which the solvent is water. It is mostly shown in chemical equations by appending (aq) to the relevant chemical formula. For example, a solution of table salt, or sodium chloride (NaCl), in water would be re ...
s, it is common to assume that the density of water is 1.00 g/mL. Therefore, it is common to equate 1 kilogram of water with 1 L of water. Consequently, 1 ppm corresponds to 1 mg/L and 1 ppb corresponds to 1 μg/L.
Similarly, parts-per notation is used also in
physics and
engineering to express the value of various proportional phenomena. For instance, a special metal alloy might expand 1.2
micrometers per
meter of length for every
degree Celsius and this would be expressed as "''
α'' = 1.2 ppm/°C". Parts-per notation is also employed to denote the change, stability, or
uncertainty in measurements. For instance, the accuracy of land-survey distance measurements when using a
laser rangefinder
A laser rangefinder, also known as a laser telemeter, is a rangefinder that uses a laser beam to determine the distance to an object. The most common form of laser rangefinder operates on the time of flight principle by sending a laser pulse in ...
might be 1 millimeter per kilometer of distance; this could be expressed as "
Accuracy = 1 ppm."
Parts-per notations are all dimensionless quantities: in mathematical expressions, the units of measurement always cancel. In fractions like "2 nanometers per meter" (2 n
m/
m = 2 nano = 2 × 10
−9 = 2 ppb = 2 × ), so the
quotients are pure-number
coefficient
In mathematics, a coefficient is a multiplicative factor in some term of a polynomial, a series, or an expression; it is usually a number, but may be any expression (including variables such as , and ). When the coefficients are themselves var ...
s with positive values less than or equal to 1. When parts-per notations, including the
percent
In mathematics, a percentage (from la, per centum, "by a hundred") is a number or ratio expressed as a fraction of 100. It is often denoted using the percent sign, "%", although the abbreviations "pct.", "pct" and sometimes "pc" are also use ...
symbol (%), are used in regular prose (as opposed to mathematical expressions), they are still pure-number dimensionless quantities. However, they generally take the literal "parts per" meaning of a comparative ratio (e.g. "2 ppb" would generally be interpreted as "two parts in a billion parts").
[BIPM]
5.3.7 ''Stating values of dimensionless quantities, or quantities of dimension one''
Parts-per notations may be expressed in terms of any unit of the same measure. For instance, the
coefficient of thermal expansion of a certain
brass alloy, ''α'' = 18.7 ppm/°C, may be expressed as 18.7 (
μm
The micrometre ( international spelling as used by the International Bureau of Weights and Measures; SI symbol: μm) or micrometer (American spelling), also commonly known as a micron, is a unit of length in the International System of Unit ...
/m)/°C, or as 18.7 (μ
in/in)/°C; the numeric value representing a relative proportion does not change with the adoption of a different unit of length. Similarly, a
metering pump that injects a trace chemical into the main process line at the proportional flow rate ''
Qp'' = 125 ppm, is doing so at a rate that may be expressed in a variety of volumetric units, including 125 μL/L, 125 μ
gal/gal, 125 cm
3/
m3, etc.
In nuclear magnetic resonance (NMR) spectroscopy
In
nuclear magnetic resonance spectroscopy (NMR),
chemical shift is usually expressed in ppm. It represents the difference of a measured frequency in parts per million from the reference frequency. The reference frequency depends on the instrument's magnetic field and the element being measured. It is usually expressed in
MHz. Typical chemical shifts are rarely more than a few hundred Hz from the reference frequency, so chemical shifts are conveniently expressed in ppm (Hz/MHz). Parts-per notation gives a dimensionless quantity that does not depend on the instrument's field strength.
Parts-per expressions
*''One part per
hundred'' is generally represented by the
percent sign (%) and denotes
one part per 100 () parts, and a value of . This is equivalent to about fourteen minutes out of one day.
*''One part per
thousand'' should generally be spelled out in full and not as "ppt" (which is usually understood to represent "parts per
trillion"). It may also be denoted by the
permille sign (‰). Note however, that specific disciplines such as oceanography, as well as educational exercises, do use the "ppt" abbreviation. "One part per thousand" denotes one part per 1,000 () parts, and a value of . This is equivalent to about ninety seconds out of one day.
*''One part per
ten thousand'' is denoted by the
permyriad sign (‱). Although rarely used in science (ppm is typically used instead), one permyriad has an unambiguous value of one part per 10,000 () parts, and a value of . This is equivalent to about nine seconds out of one day.
In contrast, in
finance
Finance is the study and discipline of money, currency and capital assets. It is related to, but not synonymous with economics, the study of production, distribution, and consumption of money, assets, goods and services (the discipline of fina ...
, the
basis point is typically used to denote changes in or differences between percentage interest rates (although it can also be used in other cases where it is desirable to express quantities in hundredths of a percent). For instance, a change in an interest rate from 5.15% per annum to 5.35% per annum could be denoted as a change of 20 basis points (per annum). As with interest rates, the words "per annum" (or "per year") are often omitted. In that case, the basis point is a quantity with a dimension of (time
−1).
* ''One part per
hundred thousand
100,000 (one hundred thousand) is the natural number following 90,000#Selected numbers in the range 90,000–99,999, 99,999 and preceding 100,001. In scientific notation, it is written as 105.
Terms for 100,000
In India, Pakistan and South Asi ...
'', ''
per cent mille'' (pcm) or ''milli-percent'' denotes one part per 100,000 () parts, and a value of . It is commonly used in
epidemiology for mortality, crime and disease prevalence rates, and nuclear reactor engineering as a unit of reactivity. In
time measurement it is equivalent to about 5 minutes out of a year; in
distance measurement, it is equivalent to 1 cm of error per km of distance traversed.
* ''One part per
million
One million (1,000,000), or one thousand thousand, is the natural number following 999,999 and preceding 1,000,001. The word is derived from the early Italian ''millione'' (''milione'' in modern Italian), from ''mille'', "thousand", plus the au ...
'' (ppm) denotes one part per 1,000,000 () parts, and a value of . It is equivalent to about 32 seconds out of a year or 1 mm of error per km of distance traversed.
* ''One part per
billion'' (ppb) denotes one part per 1,000,000,000 () parts, and a value of . This is equivalent to about three seconds out of a
century
A century is a period of 100 years. Centuries are numbered ordinally in English and many other languages. The word ''century'' comes from the Latin ''centum'', meaning ''one hundred''. ''Century'' is sometimes abbreviated as c.
A centennial or ...
.
* ''One part per
trillion'' (ppt) denotes one part per 1,000,000,000,000 () parts, and a value of . This is equivalent to about thirty seconds out of every million years.
* ''One part per
quadrillion'' (ppq) denotes one part per 1,000,000,000,000,000 () parts, and a value of . This is equivalent to about two and a half minutes out of the
age of the Earth
The age of Earth is estimated to be 4.54 ± 0.05 billion years This age may represent the age of Earth's accretion, or core formation, or of the material from which Earth formed. This dating is based on evidence from radiometric age-dating of ...
(4.5 billion years). Although relatively uncommon in analytical chemistry, measurements at the ppq level are sometimes performed.
Criticism
Although the
International Bureau of Weights and Measures (an international standards organization known also by its
French
French (french: français(e), link=no) may refer to:
* Something of, from, or related to France
** French language, which originated in France, and its various dialects and accents
** French people, a nation and ethnic group identified with Franc ...
-language initials BIPM) recognizes the use of parts-per notation, it is not formally part of the
International System of Units
The International System of Units, known by the international abbreviation SI in all languages and sometimes pleonastically as the SI system, is the modern form of the metric system and the world's most widely used system of measurement. E ...
(SI).
Note that although "
percent
In mathematics, a percentage (from la, per centum, "by a hundred") is a number or ratio expressed as a fraction of 100. It is often denoted using the percent sign, "%", although the abbreviations "pct.", "pct" and sometimes "pc" are also use ...
" (%) is not formally part of the SI, both the BIPM and the
International Organization for Standardization (ISO) take the position that ''"in mathematical expressions, the internationally recognized symbol % (percent) may be used with the SI to represent the number 0.01"'' for dimensionless quantities.
According to
IUPAP, ''"a continued source of annoyance to unit purists has been the continued use of percent, ppm, ppb, and ppt"''.
Although
SI-compliant expressions should be used as an alternative, the parts-per notation remains nevertheless widely used in technical disciplines. The main problems with the parts-per notation are set out below.
Long and short scales
Because the
named numbers starting with a "
billion" have different values in different countries, the BIPM suggests avoiding the use of "ppb" and "ppt" to prevent misunderstanding. The U.S.
National Institute of Standards and Technology (NIST) takes the stringent position, stating that ''"the language-dependent terms
..are not acceptable for use with the SI to express the values of quantities"''.
Thousand vs. trillion
Although "ppt" usually means "parts per trillion", it occasionally means "parts per thousand". Unless the meaning of "ppt" is defined explicitly, it has to be determined from the context.
Mass fraction vs. mole fraction vs. volume fraction
Another problem of the parts-per notation is that it may refer to
mass fraction,
mole fraction or
volume fraction. Since it is usually not stated which quantity is used, it is better to write the unit as kg/kg, mol/mol or m
3/m
3 (even though they are all dimensionless). The difference is quite significant when dealing with gases, and it is very important to specify which quantity is being used. For example, the conversion factor between a mass fraction of 1 ppb and a mole fraction of 1 ppb is about 4.7 for the greenhouse gas
CFC-11 in air. For volume fraction, the suffix "V" or "v" is sometimes appended to the parts-per notation (e.g. ppmV, ppbv, pptv). Unfortunately, ppbv and pptv are also often used for mole fractions (which is identical to volume fraction only for ideal gases).
To distinguish the mass fraction from volume fraction or mole fraction, the letter "w" (standing for "weight") is sometimes added to the abbreviation (e.g. ppmw, ppbw).
The usage of the parts-per notation is generally quite fixed within each specific branch of science, but often in a way that is inconsistent with its usage in other branches, leading some researchers to assume that their own usage (mass/mass, mol/mol, volume/volume, or others) is correct and that other usages are incorrect. This assumption sometimes leads them to not specify the details of their own usage in their publications, and others may therefore misinterpret their results. For example,
electrochemists often use volume/volume, while
chemical engineers may use mass/mass as well as volume/volume. Many academic publications of otherwise excellent level fail to specify their usage of the parts-per notation.
SI-compliant expressions
SI-compliant units that can be used as alternatives are shown in the chart below. Expressions that the BIPM explicitly does not recognize as being suitable for denoting dimensionless quantities with the SI are marked with
!.
Note that the notations in the "SI units" column above are all
dimensionless quantities; that is, the units of measurement factor out in expressions like "1 nm/m" (1 n
m/
m = 1 nano = 1 × 10
−9) so the
quotients are pure-number
coefficient
In mathematics, a coefficient is a multiplicative factor in some term of a polynomial, a series, or an expression; it is usually a number, but may be any expression (including variables such as , and ). When the coefficients are themselves var ...
s with values less than 1.
Uno (proposed dimensionless unit)
Because of the cumbersome nature of expressing certain dimensionless quantities per SI guidelines, the
International Union of Pure and Applied Physics (IUPAP) in 1999 proposed the adoption of the special name "uno" (symbol: U) to represent the number 1 in dimensionless quantities.
In 2004, a report to the
International Committee for Weights and Measures (CIPM) stated that response to the proposal of the uno "had been almost entirely negative", and the principal proponent "recommended dropping the idea".
To date, the uno has not been adopted by any
standards organization, and it appears unlikely that it will ever become an officially sanctioned way to express low-value (high-ratio) dimensionless quantities.
See also
*
International Electrotechnical Commission
The International Electrotechnical Commission (IEC; in French: ''Commission électrotechnique internationale'') is an international standards organization that prepares and publishes international standards for all electrical, electronic and r ...
(IEC)
*
Milligram per cent
*
Percentage
In mathematics, a percentage (from la, per centum, "by a hundred") is a number or ratio expressed as a fraction of 100. It is often denoted using the percent sign, "%", although the abbreviations "pct.", "pct" and sometimes "pc" are also us ...
(%) 1 part in 100
*
Per mille (‰) 1 part in 1,000
*
Permyriad (‱) 1 part in 10,000
*
Per cent mille (pcm) 1 part in 100,000
*
Per-unit system
References
External links
* {{Commonscatinline
* National Institute of Standards and Technology (NIST)
Home page* International Bureau of Weights and Measures (BIPM)
Home page
Analytical chemistry
Chemical nomenclature
Dimensionless numbers
Environmental chemistry
Mathematical terminology
Measurement
Metrics
Physical constants
Units of measurement