A motor capacitor, such as a start capacitor or run capacitor (including a dual run capacitor) is an electrical
capacitor A capacitor is a device that stores electrical energy in an electric field by virtue of accumulating electric charges on two close surfaces insulated from each other. It is a passivity (engineering), passive electronic component with two termi ...
that alters the current to one or more windings of a single-phase alternating-current
induction motor An induction motor or asynchronous motor is an AC electric motor in which the electric current in the rotor needed to produce torque is obtained by electromagnetic induction from the magnetic field of the stator winding. An induction motor ...
to create a rotating magnetic field. There are two common types of motor capacitors: ''run capacitors'' and ''start capacitors''. Motor capacitors are used with single-phase electric motors that are in turn used to drive
air conditioner Air conditioning, often abbreviated as A/C or AC, is the process of removing heat from an enclosed space to achieve a more comfortable interior environment (sometimes referred to as 'comfort cooling') and in some cases also strictly controlling ...
s, hot tub/
jacuzzi Jacuzzi Brands LLC (; ), through its subsidiaries, is a global manufacturer and distributor of branded baths, hot tubs, pools, saunas and, formerly, aircraft. Founded in 1915 by the Italian family of the same name, Jacuzzi is a federally regis ...
spa pumps, powered gates, large fans or
forced-air A forced-air central heating system is one which uses air as its heat transfer medium. These systems rely on ductwork, vents, and plenums as means of air distribution, separate from the actual heating and air conditioning systems. The return ...
heat furnaces for example. A "dual run capacitor" is used in some
air conditioner Air conditioning, often abbreviated as A/C or AC, is the process of removing heat from an enclosed space to achieve a more comfortable interior environment (sometimes referred to as 'comfort cooling') and in some cases also strictly controlling ...
compressor units, to boost both the fan and compressor motors.


Start capacitors

Start capacitors briefly increase motor starting torque and allow a motor to be cycled on and off rapidly. A start capacitor stays in the circuit long enough to rapidly bring the motor up to a predetermined speed, which is usually about 75% of the full speed, and is then taken out of the circuit, often by a
centrifugal switch A centrifugal switch is an electric switch that operates using the centrifugal force created from a rotating shaft, most commonly that of an electric motor or gasoline engine. The switch is designed to activate or de-activate as a function of t ...
that releases at that speed. Afterward the motor works more efficiently with a run capacitor.Motor start and motor run capacitors; capacitorguide.com
/ref> Start capacitors usually have ratings above 70µF, with four major voltage classifications: 125V, 165V, 250V, and 330V. Start capacitors above 20µF are always non-polarized aluminium
electrolytic capacitor An electrolytic capacitor is a polarized capacitor whose anode or positive plate is made of a metal that forms an insulating oxide layer through anodization. This oxide layer acts as the dielectric of the capacitor. A solid, liquid, or gel e ...
s with non solid electrolyte and therefore they are only applicable for the short motor starting time. The motor will not work properly if the
centrifugal switch A centrifugal switch is an electric switch that operates using the centrifugal force created from a rotating shaft, most commonly that of an electric motor or gasoline engine. The switch is designed to activate or de-activate as a function of t ...
is broken. If the switch is always open, the start capacitor is not part of the circuit, so the motor does not start. If the switch is always closed, the start capacitor is always in the circuit, so the motor windings will likely burn out. If a motor does not start, the capacitor is far more likely the problem than the switch.


Run capacitors

Some single-phase AC electric motors require a "run capacitor" to energize the second-phase winding (auxiliary coil) to create a rotating magnetic field while the motor is running. Run capacitors are designed for continuous duty while the motor is powered, which is why electrolytic capacitors are avoided, and low-loss
polymer capacitor A polymer capacitor, or more accurately a polymer electrolytic capacitor, is an electrolytic capacitor (e-cap) with a solid conductive polymer electrolyte. There are four different types: * Polymer tantalum electrolytic capacitor (Polymer Ta-e- ...
s are used. Run capacitors are mostly polypropylene
film capacitor Film capacitors, plastic film capacitors, film dielectric capacitors, or polymer film capacitors, generically called film caps as well as power film capacitors, are electrical capacitors with an insulating plastic film as the dielectric, sometime ...
s (historically: metallised paper capacitors) and are energized the entire time the motor is running. Run capacitors are rated in a range of 1.5 to 100 µF, with volt classifications of 250, 370 and 440 V. If a wrong capacitance value is installed, it will cause an uneven magnetic field around the rotor. This causes the rotor to hesitate at the uneven spots, resulting in irregular rotation, especially under load. This hesitation can cause the motor to become noisy, increase energy consumption, cause performance to drop and the motor to overheat.


Dual run capacitors

A dual run capacitor supports two electric motors, with both a fan motor and a compressor motor. It saves space by combining two physical capacitors into one case. The dual capacitor has three terminals, labeled ''C'' for common, ''FAN'', and ''HERM'' for hermetically-sealed compressor. Dual capacitors come in a variety of sizes, depending on the capacitance (measured in microfarads, µF), such as 40 plus 5µF, and also on the voltage. A 440-volt capacitor can be used in place of a 370-volt, but not a 370-volt in place of a 440-volt. The capacitance must remain within 5% of its original value. Round cylinder-shaped dual run capacitors are commonly used for
air conditioning Air conditioning, often abbreviated as A/C or AC, is the process of removing heat from an enclosed space to achieve a more comfortable interior environment (sometimes referred to as 'comfort cooling') and in some cases also strictly controlling ...
, to help in the starting of the compressor and the condenser fan motor. An oval dual run capacitor could be used instead of a round capacitor; in either case the mounting strap needs to fit the shape used.


Labeling

The units of capacitance are labeled in microfarads (µF). Older capacitors may be labeled with the obsolete terms "mfd" or "MFD" which can be ambiguous but are, especially in this context, used for microfarad as well (a millifarad is 1000 microfarad and not usually seen on motors).


Failure modes

A faulty run capacitor often becomes swollen, with the sides or ends bowed or bulged out further than usual; it can then be clear to see that the capacitor has failed, because it is swollen or even blown apart causing the capacitor's
electrolyte An electrolyte is a medium containing ions that is electrically conducting through the movement of those ions, but not conducting electrons. This includes most soluble salts, acids, and bases dissolved in a polar solvent, such as water. Upon dis ...
to leak out. Some capacitors have a "pressure sensitive interrupter" design that causes them to fail before internal pressures can cause serious injury. One such design causes the top of the capacitor to expand and break internal wiring. Over many years of use the capacitance of the capacitor drops; this is known as a "weak capacitor". As a result, the motor may fail to start or to run at full power. When a motor is running during a lightning strike on the power grid, the run capacitor may be damaged or weakened by a voltage spike, thus requiring replacement.
IEC The International Electrotechnical Commission (IEC; in French: ''Commission électrotechnique internationale'') is an international standards organization that prepares and publishes international standards for all electrical, electronic and r ...
/EN 60252-1 2011 specifies the following levels of protection for motor run capacitors: *S0 - no protection; *S1, S2 - fail open circuit or short circuit; *S3 - fail open circuit only.


Safety issues


Heat

The motor capacitor, which is a component of a hot tub circulating pump, can overheat if defective. This poses a fire hazard, and the
U.S. Consumer Product Safety Commission The United States Consumer Product Safety Commission (USCPSC, CPSC, or commission) is an independent agency of the United States government. The CPSC seeks to promote the safety of consumer products by addressing “unreasonable risks” of in ...
(CPSC) has received more than 100 reports of incidents of overheating of the motor capacitor, with some fires started."CPSC, Firms Announce Recall of Infinity and Lifestyle Spas" U.S. CPSC, Washington, DC, CPSC.gov, 2003-12-09, webpage
CP7
.


Toxic

Motor capacitors manufactured before 1978 likely contain
polychlorinated biphenyls Polychlorinated biphenyls (PCBs) are highly carcinogenic chemical compounds, formerly used in industrial and consumer products, whose production was banned in the United States by the Toxic Substances Control Act in 1979 and internationally by ...
(PCBs). These are extremely toxic and persistent chemicals with many long-lasting negative human and wildlife health effects. Capacitors were required to be labeled in the U.S. with "No PCBs" or similar language. Capacitors without these labels are suspect. PCB containing capacitors must be replaced, and disposed by consulting local environmental authorities. If these capacitors leak or fail pcbs can be released into the environment and will very likely result in extremely expensive environmental cleanups, and potentially, lawsuits. There are extensive toxicological reports on PCBs in the research community.
U.S. EPA The Environmental Protection Agency (EPA) is an independent executive agency of the United States federal government tasked with environmental protection matters. President Richard Nixon proposed the establishment of EPA on July 9, 1970; it be ...
has much information on the correct way to test and manage these toxic chemicals in older capacitors".https://www.epa.gov/sites/production/files/documents/pcbidmgmt.pdf


References

{{Reflist Calculate your kvar requirement for your motor
Calculate kvar for motor


External links

* http://highperformancehvac.com/run-start-capacitors-hvac-motors-1/ * http://www.capacitorformotor.com/motor_capacitor.html * http://www.wikihow.com/Check-a-Start-Capacitor * http://electronics.stackexchange.com/questions/101408/what-is-the-purpose-of-the-motor-run-capacitor * https://www.epa.gov/sites/production/files/documents/pcbidmgmt.pdf Electric motors Capacitors Heating, ventilation, and air conditioning