MiniMed Paradigm is a series of
insulin pump An insulin pump is a medical device used for the administration of insulin in the treatment of diabetes mellitus, also known as continuous subcutaneous insulin therapy. The device configuration may vary depending on design. A traditional pump ...
s manufactured by
Medtronic Medtronic plc is an American medical device company. The company's operational and executive headquarters are in Minneapolis, Minnesota, and its legal headquarters are in Ireland due to its acquisition of Irish-based Covidien in 2015. While it ...
for patients with
diabetes mellitus Diabetes, also known as diabetes mellitus, is a group of metabolic disorders characterized by a high blood sugar level ( hyperglycemia) over a prolonged period of time. Symptoms often include frequent urination, increased thirst and increased ap ...
. The pump operates with a single AA battery and uses a piston-plunger
pump A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action, typically converted from electrical energy into hydraulic energy. Pumps can be classified into three major groups according to the method they u ...
to
infuse Infusion is the process of extracting chemical compounds or flavors from plant material in a solvent such as water, edible oil, oil or Ethanol, alcohol, by allowing the material to remain suspended in the solvent over time (a process often call ...
a programmed amount of
insulin Insulin (, from Latin ''insula'', 'island') is a peptide hormone produced by beta cells of the pancreatic islets encoded in humans by the ''INS'' gene. It is considered to be the main anabolic hormone of the body. It regulates the metabolism o ...
into the patient through a length of tubing. The Paradigm uses a one-way wireless
radio frequency Radio frequency (RF) is the oscillation rate of an alternating electric current or voltage or of a magnetic, electric or electromagnetic field or mechanical system in the frequency range from around to around . This is roughly between the upp ...
link to receive
blood sugar Glycaemia, also known as blood sugar level, blood sugar concentration, or blood glucose level is the measure of glucose concentrated in the blood of humans or other animals. Approximately 4 grams of glucose, a simple sugar, is present in the blo ...
measurements from select
glucose meter A glucose meter, also referred to as a "glucometer", is a medical device for determining the approximate concentration of glucose in the blood. It can also be a strip of glucose paper dipped into a substance and measured to the glucose chart. ...
s. The Paradigm RT (Real Time) series adds the ability to receive data from a mated continuous blood-glucose monitor. Although the pump can use these measurements to assist in calculating a dose of insulin, no actual change in insulin delivery occurs without manual user-intervention. In the
United States The United States of America (U.S.A. or USA), commonly known as the United States (U.S. or US) or America, is a country primarily located in North America. It consists of 50 states, a federal district, five major unincorporated territorie ...
, the device is regulated by a
branch A branch, sometimes called a ramus in botany, is a woody structural member connected to the central trunk (botany), trunk of a tree (or sometimes a shrub). Large branches are known as boughs and small branches are known as twigs. The term '' ...
of the
Food and Drug Administration The United States Food and Drug Administration (FDA or US FDA) is a List of United States federal agencies, federal agency of the United States Department of Health and Human Services, Department of Health and Human Services. The FDA is respon ...
.


Description

Insulin pumps are
drug delivery device Drug delivery refers to approaches, formulations, manufacturing techniques, storage systems, and technologies involved in transporting a pharmaceutical compound to its target site to achieve a desired therapeutic effect. Principles related to d ...
s used to treat patients with type 1 and type 2 diabetes. The Minimed Paradigm REAL-Time and Continuous Glucose Monitoring (CGM) system, which received FDA clearance in 2006, uses tubing and a reservoir with rapid-acting insulin. This "infusion set" is patient-connected via a catheter to the abdomen region. The infusion set can remain in the place for three days while the pump is clip-belt worn. There is a quick-disconnect feature for the tubing. The pump delivers insulin in two modes. In
Basal rate Basal rate, in biology, is the rate of continuous supply of some chemical or process. In the case of diabetes mellitus, it is a low rate of continuous insulin supply needed for such purposes as controlling cellular glucose and amino acid Ami ...
mode, the delivery is continuous in small doses similar to a
pancreas The pancreas is an organ of the digestive system and endocrine system of vertebrates. In humans, it is located in the abdomen behind the stomach and functions as a gland. The pancreas is a mixed or heterocrine gland, i.e. it has both an end ...
, for example 0.15 units per hour throughout the day. Basal rates are set to meet individual
metabolic rate Metabolism (, from el, μεταβολή ''metabolē'', "change") is the set of life-sustaining chemical reactions in organisms. The three main functions of metabolism are: the conversion of the energy in food to energy available to run cell ...
s. In Bolus mode, the delivery is programmed to be a one-time delivery prior to eating or after an unexpected high, for example 18 units spread out to several hours. This type of continuous treatment is in contrast to traditional multiple daily injections (MDI) that use slower-acting insulin. Continuous treatment reduces glucose variability. The Paradigm system consists of two basic parts: an insulin pump and an optional glucose sensor CGM worn for up to 3 days. The disposable sensor is
subcutaneously The subcutaneous tissue (), also called the hypodermis, hypoderm (), subcutis, superficial fascia, is the lowermost layer of the integumentary system in vertebrates. The types of cells found in the layer are fibroblasts, adipose cells, and macro ...
-placed to make glucose measurements in
interstitial fluid In cell biology, extracellular fluid (ECF) denotes all body fluid outside the cells of any multicellular organism. Total body water in healthy adults is about 60% (range 45 to 75%) of total body weight; women and the obese typically have a lower ...
every 5 minutes and transmit the reading via low power radio frequency (
ISM band The ISM radio bands are portions of the radio spectrum reserved internationally for industrial, scientific and medical (ISM) purposes, excluding applications in telecommunications. Examples of applications for the use of radio frequency (RF) ener ...
) to the pump for realtime display. However, insulin therapy may be conducted without CGM and although there is not yet an automated insulin-regulation feedback mechanism between measure and infusion to control the amount and timing of insulin, this is clearly a future objective. So any change in basal or bolus is patient-driven by programming the pump using the Bolus Wizard. The latest model pumps are the MiniMed Paradigm 522 and 722 which differ in reservoir size, 176 versus 300 units, respectively. In 2007 the FDA approved a pediatric model for patients 7 to 17 years old.


History

The development history of the Minimed pump goes back to the 1980s. * 1983 – 1st Pump MiniMed 502 (Eli Lilly makes synthetic insulin) * 1985 – MiniMed 504 Insulin Pump * 1992 – Launch Of MiniMed 506 Insulin Pump * 1996 – Introduction of MiniMed 507 Pump * 1999 – Launch of the Model 507C * 1999 – Introduction of MiniMed 508 Insulin Pump * 2002 – Inauguration of the MiniMed Paradigm 511 * 2003 – 1st Wireless MiniMed Paradigm 512/712 (followed by 515/715) * 2006 – MiniMed Paradigm REAL-Time 522/722 * 2010 – MiniMed Paradigm REAL-Time Revel 523/723


FDA Classification

The
Food and Drug Administration The United States Food and Drug Administration (FDA or US FDA) is a List of United States federal agencies, federal agency of the United States Department of Health and Human Services, Department of Health and Human Services. The FDA is respon ...
has at least six classifications for the various parts of the Minimed Paradigm System.


Competitors devices

Competitive devices includes Deltec Cozmo, Animas Ping, Tandem Diabetes Care, Inc., Insulet OmniPod,
Accu-chek F. Hoffmann-La Roche AG, commonly known as Roche, is a Swiss multinational healthcare company that operates worldwide under two divisions: Pharmaceuticals and Diagnostics. Its holding company, Roche Holding AG, has shares listed on the SIX S ...
Spirit Combo, and Sooil DiabecareIIS.


Future devices

Currently, Medtronic has the following
research and development Research and development (R&D or R+D), known in Europe as research and technological development (RTD), is the set of innovative activities undertaken by corporations or governments in developing new services or products, and improving existi ...
projects in its pipeline: Next Generation REAL-Time Continuous Glucose Monitoring System; Next Generation Insulin Pump; Pre-filled Insulin Reservoirs; Implantable Insulin Pump; and
Artificial pancreas Automated insulin delivery systems are automated (or semi-automated) systems designed to assist people with diabetes, primarily type 1, by automatically adjusting insulin delivery to help them control their blood glucose levels. Currently available ...
(Semi-Automated System & Closed-Loop System). The industry trend in portable devices has piggybacked on the success of wireless technology but not on the success of other disciplines, such as
dynamical system In mathematics, a dynamical system is a system in which a Function (mathematics), function describes the time dependence of a Point (geometry), point in an ambient space. Examples include the mathematical models that describe the swinging of a ...
,
Cybernetics Cybernetics is a wide-ranging field concerned with circular causality, such as feedback, in regulatory and purposive systems. Cybernetics is named after an example of circular causal feedback, that of steering a ship, where the helmsperson m ...
and
adaptive systems An adaptive system is a set of interacting or interdependent entities, real or abstract, forming an integrated whole that together are able to respond to environmental changes or changes in the interacting parts, in a way analogous to either conti ...
, for
root cause Root cause may refer to: * "Root Cause" (''Person of Interest''), a TV show episode * Root cause analysis In science Science is a systematic endeavor that builds and organizes knowledge in the form of testable explanations and predic ...
solutions to close the "true" loop. While the slow-responding dynamics in the physiology of glucose regulation is not beyond the mathematics of
PID controller A proportional–integral–derivative controller (PID controller or three-term controller) is a control loop mechanism employing feedback that is widely used in industrial control systems and a variety of other applications requiring continuou ...
s, 50 years of patient-perspective "advancement" says it is beyond the
corporate A corporation is an organization—usually a group of people or a company—authorized by the state to act as a single entity (a legal entity recognized by private and public law "born out of statute"; a legal person in legal context) and re ...
, congressional, and
lobbying In politics, lobbying, persuasion or interest representation is the act of lawfully attempting to influence the actions, policies, or decisions of government officials, most often legislators or members of regulatory agency, regulatory agencie ...
leaders. Also, the accuracy of existing continuous glucose monitoring systems poses a problem for an artificial pancreas.


References

* ADA - CSII
Diabetes Care ''Diabetes Care'' is a monthly peer-reviewed medical journal published since 1978 by the American Diabetes Association. The journal covers research in the following five categories: 1) clinical care/education/nutrition/psychosocial research, 2) ...
2004; 27: S110. * ADA - Implications of the DCCT study ''Diabetes Care'' 2002; 25: 25-27. * ADA - Implications of the UKPD Study ''Diabetes Care'' 2002; 25: 28-32. * * * * ''Diabetes Technol Ther.'' 2004;6(2):105-13. * * * * * The DCCT Research Group.
JAMA ''The Journal of the American Medical Association'' (''JAMA'') is a peer-reviewed medical journal published 48 times a year by the American Medical Association. It publishes original research, reviews, and editorials covering all aspects of biom ...
. 1997;227(5):374-4 Skyler J.S. Diabtes Technol Ther. 2000. * The DCCT Research Group. Progression of retinopathy with intensive versus conventional treatment in the diabetes control and complications trial. 1994. * The DCCT/EDIC Study Research Group. Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes. ''
NEJM ''The New England Journal of Medicine'' (''NEJM'') is a weekly medical journal published by the Massachusetts Medical Society. It is among the most prestigious peer-reviewed medical journals as well as the oldest continuously published one. Hist ...
'' 2005; 353(25): 2643-2653. * The Expert Committee on the Diagnosis and Classification of Diabetes Mellitus. Report of the expert committee on the diagnosis and classification of diabetes mellitus ''Diabetes Care'' 2001; 24: 1. * * * * * * * *


Notes

{{Medtronic, state=autocollapse Medical pumps Insulin therapies Medtronic