Live-cell imaging is the study of living cells using
time-lapse microscopy Time-lapse microscopy is time-lapse photography applied to microscopy. Microscope image sequences are recorded and then viewed at a greater speed to give an accelerated view of the microscopic process. Before the introduction of the video tape r ...
. It is used by scientists to obtain a better understanding of biological function through the study of cellular dynamics. Live-cell imaging was pioneered in the first decade of the 21st century. One of the first time-lapse microcinematographic films of cells ever made was made by Julius Ries, showing the fertilization and development of the
sea urchin Sea urchins () are spiny, globular echinoderms in the class Echinoidea. About 950 species of sea urchin live on the seabed of every ocean and inhabit every depth zone from the intertidal seashore down to . The spherical, hard shells (tests) o ...
egg. Since then, several microscopy methods have been developed to study living cells in greater detail with less effort. A newer type of imaging using
quantum dots Quantum dots (QDs) are semiconductor particles a few nanometres in size, having optical and electronic properties that differ from those of larger particles as a result of quantum mechanics. They are a central topic in nanotechnology. When the ...
have been used, as they are shown to be more stable. The development of holotomographic microscopy has disregarded phototoxicity and other staining-derived disadvantages by implementing digital staining based on cells’ refractive index.


Overview

Biological system A biological system is a complex network which connects several biologically relevant entities. Biological organization spans several scales and are determined based different structures depending on what the system is. Examples of biological syst ...
s exist as a complex interplay of countless cellular components interacting across four dimensions to produce the phenomenon called life. While it is common to reduce living organisms to non-living samples to accommodate traditional static imaging tools, the further the sample deviates from the native conditions, the more likely the delicate processes in question will exhibit perturbations. The onerous task of capturing the true
physiological Physiology (; ) is the scientific study of functions and mechanisms in a living system. As a sub-discipline of biology, physiology focuses on how organisms, organ systems, individual organs, cells, and biomolecules carry out the chemica ...
identity of living tissue, therefore, requires high-resolution visualization across both space and time within the parent organism. The technological advances of live-cell imaging, designed to provide spatiotemporal images of
subcellular The cell is the basic structural and functional unit of life forms. Every cell consists of a cytoplasm enclosed within a membrane, and contains many biomolecules such as proteins, DNA and RNA, as well as many small molecules of nutrients an ...
events in real time, serves an important role for corroborating the biological relevance of physiological changes observed during experimentation. Due to their contiguous relationship with physiological conditions, live-cell assays are considered the standard for probing complex and dynamic cellular events. As dynamic processes such as
migration Migration, migratory, or migrate may refer to: Human migration * Human migration, physical movement by humans from one region to another ** International migration, when peoples cross state boundaries and stay in the host state for some minimum le ...
, cell development, and intracellular trafficking increasingly become the focus of biological research, techniques capable of capturing 3-dimensional data in real time for cellular networks (''
in situ ''In situ'' (; often not italicized in English) is a Latin phrase that translates literally to "on site" or "in position." It can mean "locally", "on site", "on the premises", or "in place" to describe where an event takes place and is used in ...
'') and entire organisms (''
in vivo Studies that are ''in vivo'' (Latin for "within the living"; often not italicized in English) are those in which the effects of various biological entities are tested on whole, living organisms or cells, usually animals, including humans, and p ...
'') will become indispensable tools in understanding biological systems. The general acceptance of live-cell imaging has led to a rapid expansion in the number of practitioners and established a need for increased spatial and temporal resolution without compromising the health of the cell.


Types of microscopy used


Phase contrast

Before the introduction of the
phase-contrast microscope __NOTOC__ Phase-contrast microscopy (PCM) is an optical microscopy technique that converts phase shifts in light passing through a transparent specimen to brightness changes in the image. Phase shifts themselves are invisible, but become visible ...
, it was difficult to observe living cells. As living cells are translucent, they must be
stained A stain is a discoloration that can be clearly distinguished from the surface, material, or medium it is found upon. They are caused by the chemical or physical interaction of two dissimilar materials. Accidental staining may make materials app ...
to be visible in a traditional
light microscope The optical microscope, also referred to as a light microscope, is a type of microscope that commonly uses visible light and a system of lenses to generate magnified images of small objects. Optical microscopes are the oldest design of microsc ...
. Unfortunately, the process of staining cells generally kills them. With the invention of the phase-contrast microscopy it became possible to observe unstained living cells in detail. After its introduction in the 1940s, live-cell imaging rapidly became popular using phase-contrast microscopy. The phase-contrast microscope was popularized through a series of time-lapse movies (see video), recorded using a photographic film camera. Its inventor, Frits Zernike, was awarded the Nobel Prize in 1953. Other later phase-contrast techniques used to observe unstained cells are Hoffman modulation and differential interference contrast microscopy.


Fluorescent

Phase-contrast microscopy does not have the capacity to observe specific proteins or other organic chemical compounds which form the complex machinery of a cell. Synthetic and organic fluorescent stains have therefore been developed to label such compounds, making them observable by fluorescent microscopy (see video). Fluorescent stains are, however, phototoxic, invasive and bleach when observed. This limits their use when observing living cells over extended periods of time. Non-invasive phase-contrast techniques are therefore often used as a vital complement to fluorescent microscopy in live-cell imaging applications.


Quantitative phase contrast

As a result of the rapid increase in pixel density of digital
image sensor An image sensor or imager is a sensor that detects and conveys information used to make an image. It does so by converting the variable attenuation of light waves (as they pass through or reflect off objects) into signals, small bursts of c ...
s, quantitative phase-contrast microscopy has emerged as an alternative microscopy method for live-cell imaging. Quantitative phase-contrast microscopy has an advantage over fluorescent and phase-contrast microscopy in that it is both non-invasive and quantitative in its nature. Due to the narrow focal depth of conventional microscopy, live-cell imaging is to a large extent currently limited to observing cells on a single plane. Most implementations of quantitative phase-contrast microscopy allow creating and focusing images at different focal planes from a single exposure. This opens up the future possibility of 3-dimensional live-cell imaging by means of fluorescence techniques. Quantitative phase-contrast microscopy with rotational scanning allow 3D time-lapse images of living cells to be acquired at high resolution.


Holotomography

Holotomography (HT) is a laser technique to measure three-dimensional
refractive index In optics, the refractive index (or refraction index) of an optical medium is a dimensionless number that gives the indication of the light bending ability of that medium. The refractive index determines how much the path of light is bent, ...
(RI) tomogram of a microscopic sample such as biological cells and tissues. Because the RI can serve as an intrinsic imaging contrast for transparent or phase objects, measurements of RI tomograms can provide label-free quantitative imaging of microscopic phase objects. In order to measure 3D RI tomogram of samples, HT employs the principle of holographic imaging and inverse scattering. Typically, multiple 2D holographic images of a sample are measured at various illumination angles, employing the principle of interferometric imaging. Then, a 3D RI tomogram of the sample is reconstructed from these multiple 2D holographic images by inversely solving light scattering in the sample. The principle of HT is very similar to X-ray computed tomography (CT), or CT scan. CT scan measures multiple 2D X-ray images of a human body at various illumination angles, and a 3D tomogram (X-ray absorptivity) is then retrieved using the inverse scattering theory. Both the X-ray CT and laser HT shares the same governing equation –
Helmholtz equation In mathematics, the eigenvalue problem for the Laplace operator is known as the Helmholtz equation. It corresponds to the linear partial differential equation \nabla^2 f = -k^2 f, where is the Laplace operator (or "Laplacian"), is the eigenvalu ...
, the
wave equation The (two-way) wave equation is a second-order linear partial differential equation for the description of waves or standing wave fields — as they occur in classical physics — such as mechanical waves (e.g. water waves, sound waves and ...
for a monochromatic wavelength. HT is also known as optical diffraction tomography. The combination of holography and rotational scanning allows long-term, label-free, live-cell recordings. Non-invasive optical nanoscopy can achieve such a lateral resolution by using a quasi-
The number (; spelled out as "pi") is a mathematical constant that is the ratio of a circle's circumference to its diameter, approximately equal to 3.14159. The number appears in many formulas across mathematics and physics. It is an irrati ...
-holographic detection scheme and complex deconvolution. The spatial frequencies of the imaged cell do not make any sense to the human eye. But these scattered frequencies are converted into a hologram and synthesize a bandpass, which has a resolution double the one normally available. Holograms are recorded from different illumination directions on the sample plane and observe sub-wavelength tomographic variations of the specimen. Nanoscale apertures serve to calibrate the tomographic reconstruction and to characterize the imaging system by means of the coherent transfer function. This gives rise to realistic inverse filtering and guarantees true complex field reconstruction. In conclusion, the 2 terminologies of (i) optical resolution (the real one) and (ii) sampling resolution (the one on the screen) are separated for 3D holotomographic microscopy.


Instrumentation and optics

Live-cell imaging represents a careful compromise between acquiring the highest-resolution image and keeping the cells alive for as long as possible. As a result, live-cell microscopists face a unique set of challenges that are often overlooked when working with fixed specimens. Moreover, live-cell imaging often employs special optical system and detector specifications. For example, ideally the microscopes used in live-cell imaging would have high signal-to-noise ratios, fast image acquisition rates to capture time-lapse video of extracellular events, and maintaining the long-term viability of the cells. However, optimizing even a single facet of image acquisition can be resource-intensive and should be considered on a case-by-case basis.


Lens designs


Low-magnification "dry"

In cases where extra space between the objective and the specimen is required to work with the sample, a dry lens can be used, potentially requiring additional adjustments of the correction collar, which changes the location of the lens in the objective, to account for differences in imaging chambers. Special objective lenses are designed with correction collars that correct for
spherical aberration In optics, spherical aberration (SA) is a type of aberration found in optical systems that have elements with spherical surfaces. Lenses and curved mirrors are prime examples, because this shape is easier to manufacture. Light rays that strik ...
s while accounting for the cover-slip thickness. In high-numerical-aperture (NA) dry objective lenses, the correction collar adjustment ring changes the position of a movable lens group to account for differences in the way the outside of the lens focuses light relative to the center. Although lens aberrations are inherent in all lens designs, they become more problematic in dry lenses, where resolution retention is key.


Oil-immersion high-NA

Oil immersion is a technique that can increase image resolution by immersing the lens and the specimen in oil with a high
refractive index In optics, the refractive index (or refraction index) of an optical medium is a dimensionless number that gives the indication of the light bending ability of that medium. The refractive index determines how much the path of light is bent, ...
. Since light bends when it passes between media with different refractive indexes, by placing oil with the same refractive index as glass between the lens and the slide, two transitions between refractive indices can be avoided. However, for most applications it is recommended that oil immersion be used with fixed (dead) specimens because live cells require an aqueous environment, and the mixing of oil and water can cause severe spherical aberrations. For some applications
silicone oil A silicone oil is any liquid polymerized siloxane with organic side chains. The most important member is polydimethylsiloxane. These polymers are of commercial interest because of their relatively high thermal stability, lubricating, and dielect ...
can be used to produce more accurate image reconstructions. Silicone oil is an attractive medium because it has a refractive index that is close to that of living cells, allowing to produce high-resolution images while minimizing spherical aberrations.


Water-immersion

Live-cell imaging requires a sample in an aqueous environment that is often 50 to 200 micrometers away from the cover glass. Therefore, water-immersion lenses can help achieve a higher resolving power due to the fact that both the environment and the cells themselves will be close to the refractive index of water. Water-immersion lenses are designed to be compatible with the refractive index of water and usually have a corrective collar that allows adjustment of the objective. Additionally, because of the higher refractive index of water, water-immersion lenses have a high
numerical aperture In optics, the numerical aperture (NA) of an optical system is a dimensionless number that characterizes the range of angles over which the system can accept or emit light. By incorporating index of refraction in its definition, NA has the proper ...
and can produce images superior to oil-immersion lens when resolving planes deeper than 0 µm.


Dipping

Another solution for live-cell imaging is the dipping lens. These lenses are a subset of water-immersion lenses that do not require a cover slip and can be dipped directly into the aqueous environment of the sample. One of the main advantages of the dipping lens is that it has a long effective working distance. Since a cover slip is not required, this type of lens can approach the surface of the specimen, and as a result, the resolution is limited by the restraints imposed by spherical aberration rather than the physical limitations of the cover slip. Although dipping lenses can be very useful, they are not ideal for all experiments, since the act of "dipping" the lens can disturb the cells in the sample. Additionally, since the incubation chamber must be open to the lens, changes in the sample environment due to evaporation must be closely monitored.


Phototoxicity and photobleaching

Today, most live imaging techniques rely on either high-illumination regimes or fluorescent labelling, both inducing phototoxicity and compromising the ability to keep cells unperturbed and alive over time. Since our knowledge of biology is driven by observation, it is key to minimize the perturbations induced by the imaging technique. The rise of
confocal microscopy Confocal microscopy, most frequently confocal laser scanning microscopy (CLSM) or laser confocal scanning microscopy (LCSM), is an optical imaging technique for increasing optical resolution and contrast of a micrograph by means of using a ...
is closely correlated with accessibility of high-power lasers, which are able to achieve high intensities of light excitation. However, the high-power output can damage sensitive
fluorophore A fluorophore (or fluorochrome, similarly to a chromophore) is a fluorescent chemical compound that can re-emit light upon light excitation. Fluorophores typically contain several combined aromatic groups, or planar or cyclic molecules with se ...
s, so the lasers usually run significantly below their full power output. Overexposure to light can result in photodamage due to
photobleaching In optics, photobleaching (sometimes termed fading) is the photochemical alteration of a dye or a fluorophore molecule such that it is permanently unable to fluoresce. This is caused by cleaving of covalent bonds or non-specific reactions between ...
or phototoxicity. The effects of photobleaching can significantly reduce the quality of fluorescent images, and in recent years there has been a significant demand for longer-lasting commercial fluorophores. One solution, the Alexa Fluor series, show little to no fading even at high laser intensities. Under physiological conditions, many cells and tissue types are exposed to only low levels of light. As a result, it is important to minimize the exposure of live cells to high doses of
ultraviolet Ultraviolet (UV) is a form of electromagnetic radiation with wavelength from 10 nm (with a corresponding frequency around 30  PHz) to 400 nm (750  THz), shorter than that of visible light, but longer than X-rays. UV radiation ...
(UV),
infrared Infrared (IR), sometimes called infrared light, is electromagnetic radiation (EMR) with wavelengths longer than those of Light, visible light. It is therefore invisible to the human eye. IR is generally understood to encompass wavelengths from ...
(IR), or fluorescence exciting wavelengths of light, which can damage DNA, raise cellular temperatures, and cause photobleaching respectively. High-energy photons absorbed by the fluorophores and the sample are emitted at longer wavelengths proportional to the
Stokes shift __NOTOC__ Stokes shift is the difference (in energy, wavenumber or frequency units) between positions of the band maxima of the absorption and emission spectra ( fluorescence and Raman being two examples) of the same electronic transition. I ...
. However, cellular organelles can be damaged when the photon energy produces chemical and molecular changes rather than being re-emitted. It is believed that the primary culprit in the light-induced toxicity experienced by live cells is a result of
free radicals In chemistry, a radical, also known as a free radical, is an atom, molecule, or ion that has at least one unpaired valence electron. With some exceptions, these unpaired electrons make radicals highly chemically reactive. Many radicals spon ...
produced by the excitation of fluorescent molecules. These free radicals are highly reactive and cause the destruction of cellular components, which can result in non-physiological behavior. One method of minimizing photo-damage is to lower the oxygen concentration in the sample to avoid the formation of
reactive oxygen species In chemistry, reactive oxygen species (ROS) are highly reactive chemicals formed from diatomic oxygen (). Examples of ROS include peroxides, superoxide, hydroxyl radical, singlet oxygen, and alpha-oxygen. The reduction of molecular oxygen () p ...
. However, this method is not always possible in live-cell imaging and may require additional intervention. Another method for reducing the effects of free radicals in the sample is the use of antifade reagents. Unfortunately, most commercial antifade reagents cannot be used in live-cell imaging because of their toxicity. Instead, natural free-radical scavengers such as
vitamin C Vitamin C (also known as ascorbic acid and ascorbate) is a water-soluble vitamin found in citrus and other fruits and vegetables, also sold as a dietary supplement and as a topical 'serum' ingredient to treat melasma (dark pigment spots) ...
or
vitamin E Vitamin E is a group of eight fat soluble compounds that include four tocopherols and four tocotrienols. Vitamin E deficiency, which is rare and usually due to an underlying problem with digesting dietary fat rather than from a diet low in vi ...
can be used without substantially altering physiological behavior on shorter time scales. Phototoxicity-free live-cell imaging has recently been developed and commercialised. Holotomographic microscopy avoids phototoxicity thanks to its low-power laser (laser class 1: 0.2 mW/mm2).


See also

*
Cytometry Cytometry is the measurement of number and characteristics of cells. Variables that can be measured by cytometric methods include cell size, cell count, cell morphology (shape and structure), cell cycle phase, DNA content, and the existence or ...
* Quantitative phase imaging *
Time-lapse microscopy Time-lapse microscopy is time-lapse photography applied to microscopy. Microscope image sequences are recorded and then viewed at a greater speed to give an accelerated view of the microscopic process. Before the introduction of the video tape r ...
* Live single-cell imaging


References


External links


Florida State University — Introduction to Live Cell Imaging Techniques
{{Optical microscopy Microscopy Microscopes Cell imaging Microbiology techniques Laboratory techniques Laboratory equipment Articles containing video clips