Lorentz Force Velocimetry
   HOME

TheInfoList



OR:

Lorentz force velocimetry (LFV) is a noncontact
electromagnetic In physics, electromagnetism is an interaction that occurs between particles with electric charge. It is the second-strongest of the four fundamental interactions, after the strong force, and it is the dominant force in the interactions of a ...
flow measurement technique. LFV is particularly suited for the measurement of velocities in liquid metals like steel or
aluminium Aluminium (aluminum in American and Canadian English) is a chemical element with the symbol Al and atomic number 13. Aluminium has a density lower than those of other common metals, at approximately one third that of steel. I ...
and is currently under development for
metallurgical Metallurgy is a domain of materials science and engineering that studies the physical and chemical behavior of metallic elements, their inter-metallic compounds, and their mixtures, which are known as alloys. Metallurgy encompasses both the sc ...
applications. The measurement of flow velocities in hot and aggressive liquids such as liquid aluminium and molten glass constitutes one of the grand challenges of industrial fluid mechanics. Apart from liquids, LFV can also be used to measure the velocity of solid materials as well as for detection of micro-defects in their structures. A Lorentz force
velocimetry Velocimetry is the measurement of the velocity of fluids. This is a task often taken for granted, and involves far more complex processes than one might expect. It is often used to solve fluid dynamics problems, study fluid networks, in industria ...
system is called Lorentz force flowmeter (LFF). A LFF measures the integrated or bulk
Lorentz force In physics (specifically in electromagnetism) the Lorentz force (or electromagnetic force) is the combination of electric and magnetic force on a point charge due to electromagnetic fields. A particle of charge moving with a velocity in an elect ...
resulting from the interaction between a liquid metal in motion and an applied magnetic field. In this case the characteristic length of the magnetic field is of the same order of magnitude as the dimensions of the channel. It must be addressed that in the case where localized magnetic fields are used, it is possible to perform local velocity measurements and thus the term Lorentz force
velocimeter A speedometer or speed meter is a gauge that measures and displays the instantaneous speed of a vehicle. Now universally fitted to motor vehicles, they started to be available as options in the early 20th century, and as standard equipment ...
is used.


Introduction

The use of magnetic fields in flow measurement date back to the 19th century, when in 1832
Michael Faraday Michael Faraday (; 22 September 1791 – 25 August 1867) was an English scientist who contributed to the study of electromagnetism and electrochemistry. His main discoveries include the principles underlying electromagnetic inducti ...
attempted to determine the velocity of the
River Thames The River Thames ( ), known alternatively in parts as the The Isis, River Isis, is a river that flows through southern England including London. At , it is the longest river entirely in England and the Longest rivers of the United Kingdom, se ...
. Faraday applied a method in which a flow (the river flow) is exposed to a magnetic field (earth magnetic field) and the induced voltage is measured using two electrodes across the same flow. This method is the basis of the one of the most successful commercial applications in flow metering known as the inductive flowmeter. The theory of such devices has been developed and comprehensively summarized by Prof. J. A. ShercliffArthur J. Shercliff: ''Theory of Electromagnetic Flow Measurement''. Cambridge University Press, . in the early 1950s. While inductive flowmeters are widely used for flow measurement in fluids at room temperatures such as beverages, chemicals and waste water, they are not suited for flow measurement of media such as hot, aggressive or for local measurements where surrounding obstacles limit access to the channel or pipe. Since they require electrodes to be inserted into the fluid, their use is limited to applications at temperatures far below the melting points of practically relevant metals. The Lorentz force velocimetry was invented by the A. Shercliff. However, it did not find practical application in these early years up until recent technical advances; in manufacturing of rare earth and non rare-earth strong permanent magnets, accurate force measurement techniques, multiphysical process simulation software for
magnetohydrodynamic Magnetohydrodynamics (MHD; also called magneto-fluid dynamics or hydro­magnetics) is the study of the magnetic properties and behaviour of electrically conducting fluids. Examples of such magneto­fluids include plasmas, liquid metals, ...
(MHD) problems that this principle could be turned into a feasible working flow measurement technique. LFV is currently being developed for applications in metallurgy as well as in other areas. Based on theory introduced by Shercliff there have been several attempts to develop flow measurement methods which do not require any mechanical contact with the fluid,. Among them is the eddy current flowmeter which measures flow-induced changes in the electric impedance of coils interacting with the flow. More recently, a non-contact method was proposed in which a magnetic field is applied to the flow and the velocity is determined from measurements of flow-induced deformations of the applied magnetic field,.


Principle and physical interpretation

The principle of Lorentz force velocimetry is based on measurements of the
Lorentz force In physics (specifically in electromagnetism) the Lorentz force (or electromagnetic force) is the combination of electric and magnetic force on a point charge due to electromagnetic fields. A particle of charge moving with a velocity in an elect ...
that occurs due to the flow of a conductive fluid under the influence of a variable
magnetic field A magnetic field is a vector field that describes the magnetic influence on moving electric charges, electric currents, and magnetic materials. A moving charge in a magnetic field experiences a force perpendicular to its own velocity and to ...
. According to Faraday's law, when a metal or conductive fluid moves through a magnetic field,
eddy current Eddy currents (also called Foucault's currents) are loops of electrical current induced within conductors by a changing magnetic field in the conductor according to Faraday's law of induction or by the relative motion of a conductor in a mag ...
s generate there by
electromotive force In electromagnetism and electronics, electromotive force (also electromotance, abbreviated emf, denoted \mathcal or ) is an energy transfer to an electric circuit per unit of electric charge, measured in volts. Devices called electrical ''transd ...
in zones of maximal magnetic field gradient (in the present case in the inlet and outlet zones).
Eddy current Eddy currents (also called Foucault's currents) are loops of electrical current induced within conductors by a changing magnetic field in the conductor according to Faraday's law of induction or by the relative motion of a conductor in a mag ...
in its turn creates induced magnetic field according to Ampère's law. The interaction between eddy currents and total magnetic field gives rise to Lorentz force that breaks the flow. By virtue of
Newton's third law Newton's laws of motion are three basic laws of classical mechanics that describe the relationship between the motion of an object and the forces acting on it. These laws can be paraphrased as follows: # A body remains at rest, or in motion ...
"actio=reactio" a force with the same magnitude but opposite direction acts upon its source - permanent magnet. Direct measurement of the magnet's reaction force allows to determine fluid's velocity, since this force is proportional to flow rate. The Lorentz force used in LFV has nothing to do with magnetic attraction or repulsion. It is only due to the eddy currents whose strength depends on the electrical conductivity, the relative velocity between the liquid and the permanent magnet as well as the magnitude of the magnetic field. So, when a liquid metal moves across magnetic field lines, the interaction of the magnetic field (which are either produced by a current-carrying coil or by a permanent magnet) with the induced eddy currents leads to a Lorentz force (with density \vec = \vec \times \vec ) which brakes the flow. The Lorentz force density is roughly
f \sim \sigma v B^2
where \sigma is the
electrical conductivity Electrical resistivity (also called specific electrical resistance or volume resistivity) is a fundamental property of a material that measures how strongly it resists electric current. A low resistivity indicates a material that readily allow ...
of the fluid, v its velocity, and B the magnitude of the magnetic field. This fact is well known and has found a variety of applications. This force is proportional to the velocity and conductivity of the fluid, and its measurement is the key idea of LFV. With the recent advent of powerful rare earth permanent magnets (like
NdFeB A hard_disk_drive.html"_;"title="Nickel-plated_neodymium_magnet_on_a_bracket_from_a_hard_disk_drive">Nickel-plated_neodymium_magnet_on_a_bracket_from_a_hard_disk_drive_ file:Nd-magnet.jpg.html" ;"title="hard_disk_drive_.html" ;"title="hard_disk_d ...
, SmCo and other kind of magnets) and tools for designing sophisticated systems by permanent magnet the practical realization of this principle has now become possible. The primary magnetic field \vec\left(\vec\right) can be produced by a permanent magnet or a primary current \vec\left(\vec\right) (see Fig. 1). The motion of the fluid under the action of the primary field induces eddy currents which are sketched in figure 3. They will be denoted by \vec\left(\vec\right) and are called secondary currents. The interaction of the secondary current with the primary magnetic field is responsible for the Lorentz force within the fluid
\vec_f = \int _f \vec \times \vec d^3\vec
which breaks the flow. The secondary currents create a magnetic field \vec\left(\vec\right), the secondary magnetic field. The interaction of the primary electric current with the secondary magnetic field gives rise to the Lorentz force on the magnet system
\vec_m = \int _m \vec \times \vec d^3\vec
The reciprocity principle for the Lorentz force velocimetry states that the electromagnetic forces on the fluid and on the magnet system have the same magnitude and act in opposite direction, namely
\vec_m = - \vec_f
The general scaling law that relates the measured force to the unknown velocity can be derived with reference to the simplified situation shown in Fig. 2. Here a small permanent magnet with dipole moment m is located at a distance L above a semi-infinite fluid moving with uniform velocity v parallel to its free surface. The analysis that leads to the scaling relation can be made quantitative by assuming that the magnet is a point dipole with dipole moment \vec = m \hat_z whose magnetic field is given by
\vec \left( \vec\right) = \frac \left\lbrace 3 \frac - \frac \right\rbrace
where \vec = \vec - L \hat _z and R = \mid \vec \mid . Assuming a velocity field \vec = v \hat _x for z < 0 , the eddy currents can be computed from Ohm's law for a moving electrically conducting fluid
\vec = \sigma \left( -\nabla \phi + \vec \times \vec \right)
subject to the boundary conditions J_z=0 at z=0 and J_z \to 0 as z \to 1. First, the scalar electric potential is obtained as
\phi \left( \vec \right) = - \frac \frac
from which the electric current density is readily calculated. They are indeed horizontal. Once they are known, the
Biot–Savart law In physics, specifically electromagnetism, the Biot–Savart law ( or ) is an equation describing the magnetic field generated by a constant electric current. It relates the magnetic field to the magnitude, direction, length, and proximity of the ...
can be used to compute the secondary magnetic field \vec \left( \vec\right) . Finally, the force is given by
\vec = \left( \vec \cdot \nabla \right) \vec
where the gradient of \vec has to be evaluated at the location of the dipole. For the problem at hand all these steps can be carried out analytically without any approximation leading to the result
F = \frac\hat_z
This provides us with the estimate
F \sim \mu_0^2 \sigma v m^2 L^


Conceptual setups

Lorentz force flowmeters are usually classified in several main conceptual setups. Some of them designed as static flowmeters where the magnet system is at rest and one measures the force acting on it. Alternatively, they can be designed as rotary flowmeters where the magnets are arranged on a rotating wheel and the spinning velocity is a measure of the flow velocity. Obviously, the force acting on a Lorentz force flowmeter depends both on the velocity distribution and on the shape of the magnet system. This classification depends on the relative direction of the magnetic field that is being applied respect to the direction of the flow. In Figure 3 one can distinguish diagrams of the longitudinal and the transverse Lorentz force flowmeters. It is important to mention that even that in figures only a coil or a magnet are sketched, the principle holds for both. Rotary LFF consists of a freely rotating permanent magnet (or an array of magnets mounted on a flywheel as shown in figure 4), which is magnetized perpendicularly to the axle it is mounted on. When such a system is placed close to a duct carrying an electrically conducting fluid flow, it rotates so that the driving torque due to the eddy currents induced by the flow is balanced by the braking torque induced by the rotation itself. The equilibrium rotation rate varies directly with the flow velocity and inversely with the distance between the magnet and the duct. In this case it is possible to measure either the torque on the magnet system or the angular velocity at which the wheel spins.


Practical applications

LFV is sought to be extended to all fluid or solid materials, providing that they are electrical conductors. As shown before, the Lorentz force generated by the flow depend linearly on the conductivity of the fluid. Typically, the electrical conductivity of molten metals is of the order of 10^6 ~ S/m so the Lorentz force is in the range of some ''mN''. However, equally important liquids as glass melts and electrolytic solutions have a conductivity of \sim ~ 1 ~ S/m giving rise to a Lorentz force of the order of micronewtons or even smaller.


High Conducting media: liquid or solid metals

Among different possibilities to measure the effect on the magnet system, it has been successfully applied those based on the measurement of the deflection of a parallel spring under an applied force. Firstly using a strain gauge and then recording the deflection of a quartz spring with an interferometer, in whose case the deformation is detected to within 0.1 nm.


Low Conducting media: Electrolytic solution or glass melts

Recent advance in LFV made it possible for metering flow velocity of media which has very low electroconductivity, particularly by varying parameters as well as using some state-of-art force measurement devices enable to measure flow velocity of electrolyte solutions with conductivity that is 106 times smaller than that for the liquid metals. There are variety of industrial and scientific applications where noncontact flow measurement through opaque walls or in opaque liquids is desirable. Such applications include flow metering of chemicals, food, beverages, blood, aqueous solutions in the pharmaceutical industry, molten salts in solar thermal power plants, and high temperature reactors as well as glass melts for high-precision optics.U. Lange and H. Loch, "Instabilities and stabilization of glass pipe flow" in ''Mathematical Simulation in Glass Technology'', Schott Series on Glass and Glass Ceramics, edited by D. Krause and H. Loch (Springer Verlag, 2002) A noncontact flowmeter is a device that is neither in mechanical contact with the liquid nor with the wall of the pipe in which the liquid flows. Noncontact flowmeters are equally useful when walls are contaminated like in the processing of radioactive materials, when pipes are strongly vibrating or in cases when portable flowmeters are to be developed. If the liquid and the wall of the pipe are transparent and the liquid contains tracer particles, optical measurement techniques,C. Tropea, A. L. Yarin, and J. F. Foss, Handbook of Experimental Fluid Mechanics, Springer-Verlag, GmbH, 2007F. Durst, A. Melling, and J. H. Whitelaw, ''Principles and Practice of Laser-Doppler Anemometry'', 2nd ed. Academic, London, 1981 are effective enough tool to perform noncontact measurements. However, if either the wall or the liquid are opaque as is often the case in food production, chemical engineering, glass making, and metallurgy, very few possibilities for noncontact flow measurement exist. The force measurement system is an important part of the Lorentz force velocimetry. With high resolution force measurement system makes the measurement of even lower conductivity possible. Up to date has the force measurement system continually being developed. At first the pendulum-like setups was used (Figure 5). One of the experimental facilities consists of two high power (410 mT) magnets made of
NdFeB A hard_disk_drive.html"_;"title="Nickel-plated_neodymium_magnet_on_a_bracket_from_a_hard_disk_drive">Nickel-plated_neodymium_magnet_on_a_bracket_from_a_hard_disk_drive_ file:Nd-magnet.jpg.html" ;"title="hard_disk_drive_.html" ;"title="hard_disk_d ...
suspended by thin wires on both side of channel thereby creating magnetic field perpendicular to the fluid flow, here deflection is measured by interferometer system,. The second setup consists of state-of-art weighting balance system (Figure 6) from which is being hanged optimized magnets on the base of Halbach array system. While the total mass of both magnet systems are equal (1 kg), this system induces 3 times higher system response due to arrangement of individual elements in the array and its interaction with predefined fluid profile. Here use of very sensitive force measuring devices is desirable, since flow velocity is being converted from the very tiny detected Lorentz Force. This force in combination with unavoidable dead weight F_G of the magnet ( F_G = m\cdot g ) is around F/F_G = 10^ . After that, the method of differential force measurement was developed. With this method two balance were used, one with magnet and the other is with same-weight-dummy. In this way the influence of environment would be reduced. Recently, it have been reported that the flow measurements by this method is possible for saltwater flows whose electrical conductivity is as small as 0.06 S/m (range of electrical conductivity of the regular water from tap).


Lorentz force sigmometry

Lorentz force sigmometry (LOFOS) is a contactless method for measuring the thermophysical properties of materials, no matter whether it is a fluid or a solid body. The precise measurements of electrical value, density, viscosity, thermal conductivity and surface tension of molten metals are in great importance in industry applications. One of the major problems in the experimental measurements of the thermophysical properties at high temperature (>1000 K) in the liquid state is the problem of chemical reaction between the hot fluid and the electrical probes. The basic equation for calculating the electrical conductivity is derived from the equation that links the mass flow rate \dot and Lorentz force F generated by magnetic field in flow:
\dot \left(t \right) = \frac F \left(t \right) \quad
where \Sigma = \frac is the specific electrical conductivity equals to the ratio of the electrical conductivity \sigma and the mass density of fluid \rho . K is a calibration factor that depends on the geometry of the LOFOS system. From equation above the cumulative mass during operating time is determined as
M=\int _^ \dot \left(t \right) dt = \frac \int _^ F \left(t \right) dt = \frac \tilde \quad ,
where \tilde is the integral of Lorentz force within the time process. From this equation and considering the specific electrical conductivity formula, one can derive the final equation to compute the electrical conductivity for the fluid, in the form
\sigma = \rho K \frac \quad .


Time-of-flight Lorentz force velocimetry

Time-of-flight Lorentz force velocimetry, is intended for contactless determination of flow rate in conductive fluids. It can be successfully used even in case when such material properties as electrical conductivity or density are not precisely known under specific outer conditions. The last reason makes time-of-flight LFV especially important for industry application. According to time-of-flight LFV (Fig. 9) two coherent measurement systems are mounted on a channel one by one. The measurement is based on getting of cross-correlating function of signals, which are registered by two magnetic measurement's system. Every system consists of permanent magnet and force sensor, so inducing of Lorentz force and measurement of the reaction force are made simultaneously. Any cross-correlation function is useful only in case of qualitative difference between signals and for creating the difference in this case turbulent fluctuations are used. Before reaching of measurement zone of a channel liquid passes artificial vortex generator that induces strong disturbances in it. And when such fluctuation-vortex reaches magnetic field of measurement system we can observe a peak on its force-time characteristic while second system still measures stable flow. Then according to the time between peaks and the distance between measurement system observer can estimate mean velocity and, hence, flow rate of the liquid by equation:
Q_ = k \frac
where D is the distance between magnet system, \tau the time delay between recorded peaks, and k is obtained experimentally for every specific liquid, as shown in figure 9.


Lorentz force eddy current testing

A different, albeit physically closely related challenge is the detection of deeply lying flaws and inhomogeneities in electrically conducting solid materials. In the traditional version of eddy current testing an alternating (AC) magnetic field is used to induce eddy currents inside the material to be investigated. If the material contains a crack or flaw which make the spatial distribution of the electrical conductivity nonuniform, the path of the eddy currents is perturbed and the impedance of the coil which generates the AC magnetic field is modified. By measuring the impedance of this coil, a crack can hence be detected. Since the eddy currents are generated by an AC magnetic field, their penetration into the subsurface region of the material is limited by the
skin effect Skin effect is the tendency of an alternating electric current (AC) to become distributed within a conductor such that the current density is largest near the surface of the conductor and decreases exponentially with greater depths in the co ...
. The applicability of the traditional version of eddy current testing is therefore limited to the analysis of the immediate vicinity of the surface of a material, usually of the order of one millimeter. Attempts to overcome this fundamental limitation using low frequency coils and superconducting magnetic field sensors have not led to widespread applications. A recent technique, referred to as Lorentz force eddy current testing (LET), exploits the advantages of applying DC magnetic fields and relative motion providing deep and relatively fast testing of electrically conducting materials. In principle, LET represents a modification of the traditional eddy current testing from which it differs in two aspects, namely (i) how eddy currents are induced and (ii) how their perturbation is detected. In LET eddy currents are generated by providing the relative motion between the conductor under test and a permanent magnet (see figure 10). If the magnet is passing by a defect, the Lorentz force acting on it shows a distortion whose detection is the key for the LET working principle. If the object is free of defects, the resulting Lorentz force remains constant.


Advantages & Limitations

The advantages of LFV are * LFV is a non-contact techniques of flow rate measurement. * LFV can be successfully applied for aggressive and high-temperature fluids like liquid metals. * Mean flow rate or mean velocity of fluid can be obtained without depending on flow's inhomogeneities and zones of turbulence. The limitations of the LFV are * Necessity of temperature control of measurement system because of strong dependence of magnet's magnetic field on temperature. High temperature could cause irretrievable loss of the magnetic properties of permanent magnet (Curie temperature). * Restriction of measurement zone by permanent magnet's dimensions. * Necessity of liquid level's control in case of work with open channel. * Rapid decay of the magnetic fields give rise to tiny forces on the magnet system.


See also

*
Magnetohydrodynamics Magnetohydrodynamics (MHD; also called magneto-fluid dynamics or hydro­magnetics) is the study of the magnetic properties and behaviour of electrically conducting fluids. Examples of such magneto­fluids include plasmas, liquid metals, ...
*
Lorentz force In physics (specifically in electromagnetism) the Lorentz force (or electromagnetic force) is the combination of electric and magnetic force on a point charge due to electromagnetic fields. A particle of charge moving with a velocity in an elect ...


External links


Official web page of Lorentz Force Velocimetry and Lorentz Force Eddy Current Testing Group


References

{{Reflist Fluid dynamics Plasma physics