HOME

TheInfoList



OR:

In various contexts of
science Science is a systematic endeavor that builds and organizes knowledge in the form of testable explanations and predictions about the universe. Science may be as old as the human species, and some of the earliest archeological evidence for ...
,
technology Technology is the application of knowledge to reach practical goals in a specifiable and reproducible way. The word ''technology'' may also mean the product of such an endeavor. The use of technology is widely prevalent in medicine, science, ...
, and manufacturing (such as
machining Machining is a process in which a material (often metal) is cut to a desired final shape and size by a controlled material-removal process. The processes that have this common theme are collectively called subtractive manufacturing, which utilizes ...
, fabricating, and
additive manufacturing 3D printing or additive manufacturing is the construction of a three-dimensional object from a CAD model or a digital 3D model. It can be done in a variety of processes in which material is deposited, joined or solidified under computer co ...
), an indicator is any of various instruments used to accurately measure small distances and
angle In Euclidean geometry, an angle is the figure formed by two Ray (geometry), rays, called the ''Side (plane geometry), sides'' of the angle, sharing a common endpoint, called the ''vertex (geometry), vertex'' of the angle. Angles formed by two ...
s, and amplify them to make them more obvious. The name comes from the concept of '' indicating'' to the user that which their naked eye cannot discern; such as the presence, or exact quantity, of some small distance (for example, a small height difference between two flat surfaces, a slight lack of
concentric In geometry, two or more objects are said to be concentric, coaxal, or coaxial when they share the same center or axis. Circles, regular polygons and regular polyhedra, and spheres may be concentric to one another (sharing the same center point ...
ity between two cylinders, or other small physical deviations). The classic mechanical version, called a dial indicator, provides a dial display similar to a clock face with clock hands; the hands point to graduations in a circular scales on the dial which represent the distance of the probe tip from a zero setting. The internal works of a mechanical dial indicator are similar to the precision clockworks of a mechanical wristwatch, employing a
rack and pinion A rack and pinion is a type of linear actuator that comprises a circular gear (the '' pinion'') engaging a linear gear (the ''rack''). Together, they convert rotational motion into linear motion. Rotating the pinion causes the rack to be driven ...
gear to read the probe position, instead of a pendulum
escapement An escapement is a mechanical linkage in mechanical watches and clocks that gives impulses to the timekeeping element and periodically releases the gear train to move forward, advancing the clock's hands. The impulse action transfers energy to ...
to read time. The side of the indicator probe shaft is cut with teeth to provide the rack gear. When the probe moves, the rack gear drives a pinion gear to rotate, spinning the indicator "clock" hand. Springs preload the gear mechanism to minimize the backlash error in the reading. Precise quality of the gear forms and bearing freedom determines the repeatable precision of measurement achieved. Since the mechanisms are necessarily delicate, rugged framework construction is required to perform reliably in harsh applications such as
machine tool A machine tool is a machine for handling or machining metal or other rigid materials, usually by cutting, boring, grinding, shearing, or other forms of deformations. Machine tools employ some sort of tool that does the cutting or shaping. All m ...
metalworking operations, similar to how wristwatches are ruggedized. Other types of indicator include mechanical devices with
cantilever A cantilever is a rigid structural element that extends horizontally and is supported at only one end. Typically it extends from a flat vertical surface such as a wall, to which it must be firmly attached. Like other structural elements, a canti ...
ed pointers and electronic devices with digital displays. Electronic versions employ an
optical Optics is the branch of physics that studies the behaviour and properties of light, including its interactions with matter and the construction of instruments that use or detect it. Optics usually describes the behaviour of visible, ultraviole ...
or
capacitive A capacitor is a device that stores electrical energy in an electric field by virtue of accumulating electric charges on two close surfaces insulated from each other. It is a passive electronic component with two terminals. The effect of a c ...
grating to detect microscopic steps in the position of the probe. Indicators may be used to check the variation in tolerance during the inspection process of a machined part, measure the
deflection Deflection or deflexion may refer to: Board games * Deflection (chess), a tactic that forces an opposing chess piece to leave a square * Khet (game), formerly ''Deflexion'', an Egyptian-themed chess-like game using lasers Mechanics * Deflection ...
of a beam or ring under laboratory conditions, as well as many other situations where a small measurement needs to be registered or indicated. Dial indicators typically measure ranges from 0.25 mm to 300 mm (0.015in to 12.0in), with graduations of 0.001 mm to 0.01 mm (
metric Metric or metrical may refer to: * Metric system, an internationally adopted decimal system of measurement * An adjective indicating relation to measurement in general, or a noun describing a specific type of measurement Mathematics In mathem ...
) or 0.00005 in to 0.001in ( imperial/customary). Various names are used for indicators of different types and purposes, including dial gauge, clock, probe indicator, pointer, test indicator, dial test indicator, drop indicator, plunger indicator, and others.


General classification

There are several variables in dial indicators: * Analog versus digital/electronic readout (most are analog) * Dial size. Typically referred to be American Gauge Design Specification (AGD): :: * Accuracy * Range of travel * Number of dial revolutions * Dial style: balanced (e.g., −15 to 0 to +15) or continuous (e.g., 0 to 30) * Graduation style: positive numbers (clockwise) or negative numbers (counterclockwise) * Revolution counters, which show the number of revolutions of the principal needle.


Principles

Indicators inherently provide relative measure only. But given that suitable references are used (for example,
gauge block Gauge blocks (also known as gage blocks, Johansson gauges, slip gauges, or Jo blocks) are a system for producing precision lengths. The individual gauge block is a metal or ceramic block that has been precision ground and lapped to a specific ...
s), they often allow a practical equivalent of absolute measure, with periodic recalibration against the references. However, the user must know how to use them properly and understand how in some situations, their measurements will still be relative rather than absolute because of factors such as cosine error (discussed later).


Applications

* In a
quality Quality may refer to: Concepts *Quality (business), the ''non-inferiority'' or ''superiority'' of something *Quality (philosophy), an attribute or a property *Quality (physics), in response theory *Energy quality, used in various science discipli ...
environment to check for consistency and accuracy in the manufacturing process. * On the ''workshop floor'' to initially set up or calibrate a machine, prior to a production run. * By toolmakers (such as
moldmaker A moldmaker (mouldmaker in English-speaking countries other than the US) or molder is a skilled tradesperson who fabricates moulds for use in casting metal products. Moldmakers are generally employed in foundries, where molds are used to cast pro ...
s) in the process of manufacturing precision tooling. * In metal
engineering Engineering is the use of scientific method, scientific principles to design and build machines, structures, and other items, including bridges, tunnels, roads, vehicles, and buildings. The discipline of engineering encompasses a broad rang ...
workshops, where a typical application is the centering of a
lathe A lathe () is a machine tool that rotates a workpiece about an axis of rotation to perform various operations such as cutting, sanding, knurling, drilling, deformation, facing, and turning, with tools that are applied to the workpiece to c ...
's workpiece in a four jaw chuck. The dial indicator is used to indicate the ''run-out'' (the misalignment between the workpiece's axis of rotational symmetry and the axis of rotation of the spindle) of the workpiece, with the ultimate aim of reducing it to a suitably small range using small chuck jaw adjustments. * In areas other than manufacturing where accurate measurements need to be recorded (e.g.,
physics Physics is the natural science that studies matter, its fundamental constituents, its motion and behavior through space and time, and the related entities of energy and force. "Physical science is that department of knowledge which r ...
). * To check for lateral
run-out Run-out or runout is an inaccuracy of rotating mechanical systems, specifically that the tool or shaft does not rotate exactly in line with the main axis. For example; when drilling, run-out will result in a larger hole than the drill's nomina ...
when affixing a new rotor to an automotive
disc brake A disc brake is a type of brake that uses the calipers to squeeze pairs of pads against a disc or a "rotor" to create friction. This action slows the rotation of a shaft, such as a vehicle axle, either to reduce its rotational speed or to hol ...
. Lateral run-out (lack of perpendicularity between the disc surface and the shaft axis, caused by deformations or more frequently by a lack of proper cleaning of the mounting surface of hub. This run-out can produce brake pedal pulsations, vibration of the vehicle when brakes are applied and can induce uneven wear of the disc. The lateral run-out can be caused by uneven torque, damaged studs, or a burr or rust between the hub and rotor. This variation can be tested with a dial indicator, and most times the variation can be more or less cancelled by reinstalling the disc in other position, so that the tolerances of both the hub and the disc tend to cancel each other. To reduce the run-out, the disc is mounted and torqued to half the specified torque (as there is no wheel to distribute stresses) then a dial Indicator is placed against the braking surface and the face of the dial is centered, the disc is slowly rotated by hand and the maximum deviation is noted. If the maximum run-out is within the maximum allowed run-out specified in the manual, the disc can be installed at that position, but if the technician wants to minimize the total lateral run-out, other around the clock positions can be tried. Excessive run-out can rapidly ruin the disc if it exceeds the specified tolerance (typically up to but most discs can attain less than or less if installed at the optimum position).


Probe indicator

Probe indicators typically consist of a graduated dial and needle driven by a
clockwork Clockwork refers to the inner workings of either mechanical devices called clocks and watches (where it is also called the movement) or other mechanisms that work similarly, using a series of gears driven by a spring or weight. A clockwork mec ...
(thus the ''clock'' terminology) to record the minor increments, with a smaller embedded clock face and needle to record the number of needle rotations on the main dial. The dial has fine gradations for precise measurement. The spring-loaded probe (or plunger) moves
perpendicular In elementary geometry, two geometric objects are perpendicular if they intersect at a right angle (90 degrees or π/2 radians). The condition of perpendicularity may be represented graphically using the ''perpendicular symbol'', ⟂. It can ...
ly to the object being tested by either retracting or extending from the indicator's body. The dial face can be rotated to any position, this is used to orient the face towards the user as well as ''set'' the zero point, there will also be some means of incorporating limit indicators (the two metallic tabs visible in the right image, at 90 and 10 respectively), these limit tabs may be rotated around the dial face to any required position. There may also be a lever arm available that will allow the indicator's probe to be retracted easily. Mounting the indicator may be done several ways. Many indicators have a mounting lug with a hole for a bolt as part of the back plate. Alternately, the device can be held by the cylindrical stem that guides the plunger using a collet or special clamp, which is the method generally used by tools designed to integrate an indicator as a primary component, such as thickness gauges and comparators. Common outside diameters for the stem are 3/8 inch and 8 mm, though there are other diameters made. Another option that a few manufacturers include is dovetail mounts compatible with those on dial test indicators.


Dial test indicator

A ''dial test indicator'', also known as a ''lever arm test indicator'' or ''finger indicator'', has a smaller measuring range than a standard dial indicator. A test indicator measures the deflection of the arm, the probe does not retract but swings in an arc around its hinge point. The lever may be interchanged for length or ball diameter, and permits measurements to be taken in narrow grooves and small bores where the body of a probe type may not reach. The model shown is bidirectional, some types may have to be switched via a side lever to be able to measure in the opposite direction. These indicators actually measure angular displacement and not linear displacement; linear distance is correlated to the angular displacement based on the correlating variables. If the cause of movement is perpendicular to the finger, the linear displacement error is acceptably small within the display range of the dial. However, this error starts to become noticeable when this cause is as much as 10° off the ideal 90°. This is called cosine error, because the indicator is only registering the cosine of the movement, whereas the user likely is interested in the net movement
vector Vector most often refers to: *Euclidean vector, a quantity with a magnitude and a direction *Vector (epidemiology), an agent that carries and transmits an infectious pathogen into another living organism Vector may also refer to: Mathematic ...
. Cosine error is discussed in more detail below. Contact points of test indicators most often come with a standard spherical tip of 1, 2, or 3 mm diameter. Many are of steel (alloy
tool steel Tool steel is any of various carbon steels and alloy steels that are particularly well-suited to be made into tools and tooling, including cutting tools, dies, hand tools, knives, and others. Their suitability comes from their distinctive har ...
or HSS); higher-end models are of carbides (such as
tungsten carbide Tungsten carbide (chemical formula: WC) is a chemical compound (specifically, a carbide) containing equal parts of tungsten and carbon atoms. In its most basic form, tungsten carbide is a fine gray powder, but it can be pressed and formed into ...
) for greater wear resistance. Other materials are available for contact points depending on application, such as ruby (high wear resistance) or Teflon or PVC (to avoid scratching the workpiece). These are more expensive and are not always available as OEM options, but they are extremely useful in applications that demand them. Modern dial test indicators are usually mounted using either an integrated stem (on the right of the image) or by a special clamp that grabs a dovetail on the indicator body. Some instruments may use special holders.


Test indicator

Prior to modern geared dial mechanisms, test indicators using a single lever or systems of levers were common. The range and precision of these devices were generally inferior to modern dial type units, with a range of 10/1000 inch to 30/1000 inch, and precision of 1/1000 inch being typical. One common single lever test indicator was the Starrett (No. 64), and those using systems of levers for amplification were made by companies such Starrett (No. 564)Sisson 1934
/ref> and Lufkin (No. 199A),Witchger 1941
/ref> as well as smaller companies like Ideal Tool Co. Devices that could be used as either a lever test indicator or a plunger type were also manufactured by Koch.Koch 1906
/ref>


Digital indicator

With the advent of electronics, the clock face (dial) has been replaced in some indicators with digital displays (usually LCDs) and the
clockwork Clockwork refers to the inner workings of either mechanical devices called clocks and watches (where it is also called the movement) or other mechanisms that work similarly, using a series of gears driven by a spring or weight. A clockwork mec ...
has been replaced by
linear encoder A linear encoder is a sensor, transducer or readhead paired with a scale that encodes position. The sensor reads the scale in order to convert the encoded position into an analog or digital signal, which can then be decoded into position by a di ...
s. Digital indicators have some advantages over their analog predecessors. Many models of digital indicator can record and transmit the data electronically to a computer, through an interface such as
RS-232 In telecommunications, RS-232 or Recommended Standard 232 is a standard originally introduced in 1960 for serial communication transmission of data. It formally defines signals connecting between a ''DTE'' (''data terminal equipment'') such a ...
or
USB Universal Serial Bus (USB) is an industry standard that establishes specifications for cables, connectors and protocols for connection, communication and power supply (interfacing) between computers, peripherals and other computers. A broad ...
. This facilitates
statistical process control Statistical process control (SPC) or statistical quality control (SQC) is the application of statistical methods to monitor and control the quality of a production process. This helps to ensure that the process operates efficiently, producing m ...
(SPC), because a computer can record the measurement results in a tabular
dataset A data set (or dataset) is a collection of data. In the case of tabular data, a data set corresponds to one or more database tables, where every column of a table represents a particular variable, and each row corresponds to a given record of the ...
(such as a
database table A table is a collection of related data held in a table format within a database. It consists of columns and rows. In relational databases, and flat file databases, a ''table'' is a set of data elements (values) using a model of vertical colum ...
or
spreadsheet A spreadsheet is a computer application for computation, organization, analysis and storage of data in tabular form. Spreadsheets were developed as computerized analogs of paper accounting worksheets. The program operates on data entered in cel ...
) and interpret them (by performing statistical analysis on them). This obviates manual recording of long columns of numbers, which not only reduces the risk of the operator introducing errors (such as digit transpositions) but also greatly improves the productivity of the process by freeing the human from time-consuming data recording and copying tasks. Another advantage is that they can be switched between metric and inch units with the press of a button, thus obviating a separate
unit conversion Conversion of units is the conversion between different units of measurement for the same quantity, typically through multiplicative conversion factors which change the measured quantity value without changing its effects. Overview The process ...
step of typing into a calculator or web browser and then typing the results.


Contact point (tip) types


Plunger (drop) indicator tips

On drop indicators, the tip of the probe usually may be interchanged with a range of shapes and sizes depending on the application. The tips typically are attached with either a #4-48 or an M2.5 screw thread. Spherical tips are often used to give ''point'' contact. Cylindrical and flat tips are also used as the need arises. Needle-shaped tips allow the tip to enter a small hole or slot. Accessory sets of tips are sold separately and inexpensively, so that even indicators that have no set of tips may be augmented with a new set.


Dial test indicator tips

Dial test indicators, whose tips swing in an arc rather than plunging linearly, usually have spherical tips. This shape gives ''point'' contact, allowing for consistent measurements as the tip moves through its arc (via consistent offset distance from ball surface to center point, regardless of ball contact angle with the measured surface). Several spherical diameters are commercially offered; 1mm, 2mm, and 3mm are the standard sizes. Despite the advantage just mentioned (regarding contact angle irrelevance) of the ball (sphere) ''itself'', the contact angle of the lever overall ''does'' matter. On most DTIs it must be parallel (0°, 180°) to the surface being measured in order for the measurement to be truly accurate, that is, for the magnitude of the dial reading to reflect the true tip movement distance without
cosine error Cosine error occurs in measuring instrument readings when the user of an instrument does not realize that the vector that an instrument is measuring does not coincide with the vector that the user wishes to measure. Often the lack of coincidence is ...
. In other words, the path of the tip's movement must coincide with the vector that is being measured; otherwise, only the cosine of the vector is being measured (yielding the error called cosine error). In such cases the indicator may still be useful, but an offset (multiplier or correction factor) must be applied to achieve a correct measurement (where the measurement is absolute rather than merely comparative). (This fact applies to the angle between the lever and the part, not to the angle between the lever and the DTI body, which is adjustable on most DTIs.) The same principle is also employed with CMM touch trigger probes (TTPs), where the machine (when used correctly) adjusts its ball-offset compensation to account for any difference between the approach vector and the surface vector. Some DTIs (such as the Interapid line and its competitors) are made with a built-in allowance such that a 12° tip angle (between the lever and the surface being measured) is the angle that corresponds to zero cosine error. This is a great convenience to the user because of the practicality of having the ball being clear of the indicator body such that the unit may pass over a surface. Changing the tip of a DTI is not as simple an affair as changing the tip of a drop indicator, because the tip, being a lever, has its length precisely matched to the clockwork inside the indicator, so that the length of the arc of its extremity's movement has a known ratio to the gears that drive the dial's needle. Thus to add a longer or shorter tip requires a correction factor to be multiplied with the dial reading in order to yield a true distance reading. DTI tips are often threaded for interchange (like drop indicator tips), with small flats to accept a spanner; but the intent regarding user-serviceable tip change is limited only to the tips that originally came with the indicator, because of the above-mentioned importance of the length. Typically a DTI comes with only a few tips, such as a small-ball tip and a large-ball tip. Neither of the above considerations (cosine error or lever length error) matters if the dial reading is being used only ''comparatively'' (rather than absolutely). But the avoidance of mistakes of the comparative-versus-absolute-confounding type rests with the knowledge and attention of the user, rather than with the instrument itself, and thus repairers of DTIs usually will not certify the accuracy of a DTI that cannot offer an accurate absolute measurement—even if it is perfectly good for comparative use alone. Such a DTI could still be certified (and labeled) for comparative use only, but because risk of user error is involved, gauge calibration rules in machine shops either demand a "comparative use only" label (if the users can be trusted to understand and follow it) or demand that the indicator be removed from service (if not).


See also

*
Indicator diagram An indicator diagram is a chart used to measure the thermal, or cylinder, performance of reciprocating steam and internal combustion engines and compressors. An indicator chart records the pressure in the cylinder versus the volume swept by the ...
, a pressure-volume diagram measured on a piston engine


References


Further reading

* *


External links

*Practica
metal
an

applications

{{Metalworking navbox, toolopen Dimensional instruments Metalworking measuring instruments