Fatigue testing is a specialised form of
mechanical testing Mechanical testing covers a wide range of tests, which can be divided broadly into two types: # those that aim to determine a material's mechanical properties, independent of geometry. # those that determine the response of a structure to a given ...
that is performed by applying cyclic loading to a ''coupon'' or structure. These tests are used either to generate
fatigue Fatigue describes a state of tiredness that does not resolve with rest or sleep. In general usage, fatigue is synonymous with extreme tiredness or exhaustion that normally follows prolonged physical or mental activity. When it does not resolve ...
life and crack growth data, identify critical locations or demonstrate the safety of a structure that may be susceptible to fatigue. Fatigue tests are used on a range of components from coupons through to full size test articles such as
automobiles A car or automobile is a motor vehicle with wheels. Most definitions of ''cars'' say that they run primarily on roads, seat one to eight people, have four wheels, and mainly transport people instead of goods. The year 1886 is regarded ...
and
aircraft An aircraft is a vehicle that is able to flight, fly by gaining support from the Atmosphere of Earth, air. It counters the force of gravity by using either Buoyancy, static lift or by using the Lift (force), dynamic lift of an airfoil, or in ...
. Fatigue tests on coupons are typically conducted using servo hydraulic test machines which are capable of applying large ''variable amplitude'' cyclic loads. ''Constant amplitude'' testing can also be applied by simpler oscillating machines. The ''fatigue life'' of a coupon is the number of cycles it takes to break the coupon. This data can be used for creating stress-life or strain-life curves. The rate of crack growth in a coupon can also be measured, either during the test or afterward using fractography. Testing of coupons can also be carried out inside
environmental chamber An environmental chamber, also called a climatic chamber or climate chamber, is an enclosure used to test the effects of specified environmental conditions on biological items, industrial products, materials, and electronic devices and components ...
s where the temperature, humidity and environment that may affect the rate of crack growth can be controlled. Because of the size and unique shape of full size test articles, special ''test rigs'' are built to apply loads through a series of hydraulic or electric
actuators An actuator is a component of a machine that is responsible for moving and controlling a mechanism or system, for example by opening a valve. In simple terms, it is a "mover". An actuator requires a control device (controlled by control signal) an ...
. Actuators aim to reproduce the significant loads experienced by a structure, which in the case of aircraft, may consist of manoeuvre, gust,
buffet A buffet can be either a sideboard (a flat-topped piece of furniture with cupboards and drawers, used for storing crockery, glasses, and table linen) or a system of serving meals in which food is placed in a public area where the diners serve ...
and ground-air-ground (GAG) loading. A representative sample or block of loading is applied repeatedly until the safe life of the structure has been demonstrated or failures occur which need to be repaired. Instrumentation such as load cells, strain gauges and displacement gauges are installed on the structure to ensure the correct loading has been applied. Periodic inspections of the structure around critical
stress concentrations In solid mechanics, a stress concentration (also called a stress raiser or a stress riser) is a location in an object where the stress is significantly greater than the surrounding region. Stress concentrations occur when there are irregularit ...
such as holes and fittings are made to determine the time detectable cracks were found and to ensure any cracking that does occur, does not affect other areas of the test article. Because not all loads can be applied, any unbalanced structural loads are typically reacted out to the test floor through non-critical structure such as the undercarriage. Airworthiness standards generally require a fatigue test to be carried out for large aircraft prior to certification to determine their ''safe life''. Small aircraft may demonstrate safety through calculations, although typically larger ''scatter'' or safety factors are used because of the additional uncertainty involved.


Coupon tests

Fatigue tests are used to obtain material data such as the rate of growth of a fatigue crack that can be used with
crack growth equation A crack growth equation is used for calculating the size of a fatigue crack growing from cyclic loads. The growth of fatigue cracks can result in catastrophic failure, particularly in the case of aircraft. A crack growth equation can be used to en ...
s to predict the fatigue life. These tests usually determine the rate of crack growth per cycle da/dN versus the
stress intensity factor In fracture mechanics, the stress intensity factor () is used to predict the stress state ("stress intensity") near the tip of a crack or notch caused by a remote load or residual stresses. It is a theoretical construct usually applied to a h ...
range \Delta K = K_\max - K_\min, where the minimum stress intensity factor K_\min corresponds to the minimum load for R > 0 and is taken to be zero for R\le 0, and R is the stress ratio R= K_\min/K_\max. Standardised tests have been developed to ensure repeatability and to allow the stress intensity factor to be easily determined but other shapes can be used providing the coupon is large enough to be mostly elastic.


Coupon shape

A variety of coupons can be used but some of the common ones are: * compact tension coupon (CT). The compact specimen uses the least amount of material for a specimen that is used to measure crack growth. Compact tension specimens typically use pins that are slightly smaller than the holes in the coupon to apply the loads. This method however prevents the accurate application of loads near zero and the coupon is therefore not recommended when negative loads need to be applied. * ''Centre Cracked Tension'' panel (CCT). The centre cracked tension or middle tension specimen is made from a flat sheet or bar containing two holes for attaching to grips . * ''Single Edge Notch Tension'' coupon (SENT). The single edge coupon is an elongated version of the compact tension coupon.


Instrumentation

The following instrumentation is commonly used for monitoring coupon tests: * Strain gauges are used to monitor the applied loading or stress fields around the crack tip. They may be placed beneath the path of the crack or on the back face of a compact tension coupon. * An
extensometer An extensometer is a device that is used to measure changes in the length of an object. It is useful for stress- strain measurements and tensile tests. Its name comes from "extension-meter". It was invented by Charles Huston who described i ...
or displacement gauge can be used to measure the
crack tip opening displacement Crack tip opening displacement (CTOD) or \delta_\text is the distance between the opposite faces of a crack tip at the 90° intercept position. The position behind the crack tip at which the distance is measured is arbitrary but commonly used is t ...
at the mouth of a crack. This value can be used to determine the stress intensity factor which will change with the length of the crack. Displacement gauges can also be used to measure the
compliance Compliance can mean: Healthcare * Compliance (medicine), a patient's (or doctor's) adherence to a recommended course of treatment * Compliance (physiology), the tendency of a hollow organ to resist recoil toward its original dimensions (this is a ...
of a coupon and the position during the loading cycle when contact between the opposite crack faces occurs in order to measure
crack closure Crack closure is a phenomenon in fatigue loading, where the opposing faces of a crack remain in contact even with an external load acting on the material. As the load is increased, a critical value will be reached at which time the crack becomes '' ...
. * Applied test loads are usually monitored on the test machine with a load cell. * A travelling
optical microscope The optical microscope, also referred to as a light microscope, is a type of microscope that commonly uses visible light and a system of lenses to generate magnified images of small objects. Optical microscopes are the oldest design of micro ...
can be use for measurement of the position of the crack tip.


Full scale fatigue tests

Full-scale tests may be used to: # Validate the proposed aircraft maintenance schedule. # Demonstrate the safety of a structure that may be susceptible to widespread fatigue damage. # Generate fatigue data # Validate expectations for crack initiation and growth pattern. # Identify critical locations # Validate software used to design and manufacture the aircraft. Fatigue tests can also be used to determine the extent that widespread fatigue damage may be a problem.


Test article

Certification requires knowing and accounting for the complete load history that has been experienced by a test article. Using test articles that have previously been used for static
proof test A proof test is a form of stress test to demonstrate the fitness of a load-bearing structure. An individual proof test may apply only to the unit tested, or to its design in general for mass-produced items. Such a structure is often subjected t ...
ing have caused problems where ''overloads'' have been applied and that can retard the rate of fatigue crack growth. The test loads are typically recorded using a data acquisition system acquiring data from possibly thousands of inputs from instrumentation installed on the test article, including: strain gages, pressure gauges, load cells, LVDTs, etc. Fatigue cracks typically initiate from high stress regions such as stress concentrations or material and manufacturing defects. It is important that the test article is representative of all of these features. Cracks may initiate from the following sources: *
Fretting Fretting refers to wear and sometimes corrosion damage of loaded surfaces in contact while they encounter small oscillatory movements tangential to the surface. Fretting is caused by adhesion of contact surface asperities, which are subsequent ...
, typically from high cycle count dynamic loads. * Mis-drilled holes or incorrectly sized holes for
interference fit An interference fit, also known as a pressed fit or friction fit is a form of fastening between two ''tight'' fitting mating parts that produces a joint which is held together by friction after the parts are pushed together. Depending on the am ...
fasteners. * Material treatment and defects such as broken inclusions. * Stress concentrations such as holes and fillets. * Scratches, impact damage.


Loading sequence

A representative block of loading is applied repeatedly until the ''safe life'' of the structure has been demonstrated or failures occur which need to be repaired. The size of the sequence is chosen so that the maximum loads which may cause retardation effects are applied sufficiently often, typically at least ten times throughout the test, so that there are no sequence effects. The loading sequence is generally filtered to eliminate applying small non-fatigue damaging cycles that would take too long to apply. Two types of filtering are typically used: # deadband filtering eliminates small cycles that completely fall within a certain range such as +/-3g. # ''rise-fall'' filtering eliminates small cycles that are less than a certain range such as 1g. The testing rate of large structures is typically limited to a few Hz and needs to avoid the resonance frequency of the structure.


Test rig

All components that are not part of the ''test article'' or instrumentation are termed the ''test rig''. The following components are typically found in ''full scale fatigue tests'': * Whiffletrees. In order to apply the correct loads to various parts of the structure, a mechanism known as a ''whiffletree'' is used to distribute the loads from a loading
actuator An actuator is a component of a machine that is responsible for moving and controlling a mechanism or system, for example by opening a valve. In simple terms, it is a "mover". An actuator requires a control device (controlled by control signal) a ...
to the test article. Loads applied to a central point are distributed through a series of pin jointed connected beams to produce known loads at the end connections. Each end connection is typically attached to a pad which is bonded onto the structure such as an aircraft wing. Hundreds of pads are usually applied to reproduce the aerodynamic and inertial loads seen on wing. Because the whiffletree consists of tension linkages, they are unable to apply compressive loads and therefore, independent whiffletrees are typically used on the upper and lower sides of wing fatigue tests. * Hydraulic, electromagnetic or pneumatic actuators are used to apply loads to the structure, either directly or through the use of a whiffletree to distribute the loads. A load cell is placed inline with the actuator and is used by the load controller to control the loads into the actuator. When many actuators are used on a flexible test structure, there may be cross-interaction between the different actuators. The load controller must ensure that spurious loading cycles are not applied to the structure as a result of this interaction. * Reaction restraints. Many of the loads such as aerodynamic and internal forces are re-acted by internal forces which are not present during a fatigue test. Hence, the loads are reacted out of the structure at non-critical points such as the undercarriage or through restraints on the fuselage. * Linear variable differential transformer can be used to measure the displacement of critical locations on the structure. Limits on these displacements can be used to signal when a structure has failed and to automatically shut down the test. * Non-representative structure. Some test structure may be expensive or unavailable and are typically replaced on the test structure with an equivalent structure. Structure that is close to actuator attachment points may see an unrealistic load that makes these areas non-representative.


Instrumentation

The following instrumentation is typically used on a fatigue test: *
strain gauge A strain gauge (also spelled strain gage) is a device used to measure strain on an object. Invented by Edward E. Simmons and Arthur C. Ruge in 1938, the most common type of strain gauge consists of an insulating flexible backing which supports ...
s *
accelerometer An accelerometer is a tool that measures proper acceleration. Proper acceleration is the acceleration (the rate of change of velocity) of a body in its own instantaneous rest frame; this is different from coordinate acceleration, which is acce ...
s * displacement gauges * load cells * crack sensor *
structural health monitoring Structural health monitoring (SHM) involves the observation and analysis of a system over time using periodically sampled response measurements to monitor changes to the material and geometric properties of engineering structures such as bridges an ...
sensors It is important to install any strain gauges on the test article that are also used for monitoring fleet aircraft. This allows the same damage calculations to be performed on the test article that are used to track the fatigue life of fleet aircraft. This is the primary way of ensuring fleet aircraft do not exceed the safe-life determined from the fatigue test.


Inspections

Inspections form a component of a fatigue test. It is important to know when a detectable crack occurs in order to determine the certified life of each component in addition to minimising the damage to surrounding structure and to develop repairs that have minimal impact on the certification of the adjacent structure. Non-destructive inspections may be carried out during testing and destructive tests may be used at the end of testing to ensure the structure retains its load carrying capacity.


Certification

Test interpretation and
certification Certification is the provision by an independent body of written assurance (a certificate) that the product, service or system in question meets specific requirements. It is the formal attestation or confirmation of certain characteristics of a ...
involves using the results from the fatigue test to justify the safe life and operation of an item. The purpose of certification is to ensure the probability of failure in service is acceptably small. The following factors may need to be considered: * number of tests * symmetry of the test structure and the applied loading * installation and certification of repairs * scatter factors * material and manufacturing process variability * environment * criticality Airworthy standards typically require that an aircraft remains safe even with the structure in a degraded state due to the presence of fatigue cracking.


Notable fatigue tests

* Cold proof loading tests of the
F-111 The General Dynamics F-111 Aardvark is a retired supersonic, medium-range, multirole combat aircraft. Production variants of the F-111 had roles that included ground attack (e.g. interdiction), strategic bombing (including nuclear weapons ca ...
. These tests involved applying static limit loads to aircraft which had been chilled to reduce the critical fracture size. Passing the test meant that there were no large fatigue cracks present. When cracks were present, the wings failed catastrophically. * The International Follow-On Structural Fatigue Test Program (IFOSTP) was a joint venture between Australia, Canada and the U.S. to fatigue test the
F/A-18 Hornet The McDonnell Douglas F/A-18 Hornet is an all-weather, twin-engine, supersonic, carrier-capable, multirole combat aircraft, designed as both a fighter and attack aircraft (hence the F/A designation). Designed by McDonnell Douglas (now pa ...
. The Australian test involved the use of electrodynamic shakers and pneumatic airbags to simulate high
angle of attack In fluid dynamics, angle of attack (AOA, α, or \alpha) is the angle between a reference line on a body (often the chord line of an airfoil) and the vector representing the relative motion between the body and the fluid through which it is m ...
buffet loads over the
empennage The empennage ( or ), also known as the tail or tail assembly, is a structure at the rear of an aircraft that provides stability during flight, in a way similar to the feathers on an arrow.Crane, Dale: ''Dictionary of Aeronautical Terms, third e ...
. *
de Havilland Comet The de Havilland DH.106 Comet was the world's first commercial jet airliner. Developed and manufactured by de Havilland in the United Kingdom, the Comet 1 prototype first flew in 1949. It featured an aerodynamically clean design with four d ...
suffered a series of
catastrophic failure A catastrophic failure is a sudden and total failure from which recovery is impossible. Catastrophic failures often lead to cascading systems failure. The term is most commonly used for structural failures, but has often been extended to many oth ...
s that ultimately proved to be fatigue despite being fatigue tested. * Fatigue tests on 110
Mustang The mustang is a free-roaming horse of the Western United States, descended from horses brought to the Americas by the Spanish. Mustangs are often referred to as wild horses, but because they are descended from once-domesticated animals, the ...
wing sets were carried out to determine the scatter in fatigue life. * The novel
No Highway No (and variant writings) may refer to one of these articles: English language * ''Yes'' and ''no'' (responses) * A determiner in noun phrases Alphanumeric symbols * No (kana), a letter/syllable in Japanese script * No symbol, displayed � ...
and movie
No Highway in the Sky ''No Highway in the Sky'' (also known as ''No Highway'') is a 1951 British black-and-white aviation drama film from 20th Century Fox, produced by Louis D. Lighton, directed by Henry Koster, that stars James Stewart, Marlene Dietrich, Glynis Jo ...
were about the fictional fatigue test of the fuselage of a passenger aircraft. * Fatigue tests have also been used to grow fatigue cracks that are too small to be detected.


References


Further reading

* *


External links

{{cite web , title=Boeing 787 conducts fatigue testing , website=
YouTube YouTube is a global online video sharing and social media platform headquartered in San Bruno, California. It was launched on February 14, 2005, by Steve Chen, Chad Hurley, and Jawed Karim. It is owned by Google, and is the second mo ...
, url=https://www.youtube.com/watch?v=TH9k9fWaFrs , access-date=18 July 2019 Aerospace engineering Fracture mechanics Materials degradation Mechanical failure modes Materials testing Tests