HOME

TheInfoList



OR:

A gasoline pump is a machine at a filling station that is used to
pump A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action, typically converted from electrical energy into hydraulic energy. Pumps can be classified into three major groups according to the method they u ...
gasoline (petrol), diesel, or other types of liquid
fuel A fuel is any material that can be made to react with other substances so that it releases energy as thermal energy or to be used for work. The concept was originally applied solely to those materials capable of releasing chemical energy but ...
into vehicles. Gasoline pumps are also known as bowsers or petrol bowsers (in
Australia Australia, officially the Commonwealth of Australia, is a Sovereign state, sovereign country comprising the mainland of the Australia (continent), Australian continent, the island of Tasmania, and numerous List of islands of Australia, sma ...
), petrol pumps (in
Commonwealth A commonwealth is a traditional English term for a political community founded for the common good. Historically, it has been synonymous with "republic". The noun "commonwealth", meaning "public welfare, general good or advantage", dates from the ...
countries), or gas pumps (in
North America North America is a continent in the Northern Hemisphere and almost entirely within the Western Hemisphere. It is bordered to the north by the Arctic Ocean, to the east by the Atlantic Ocean, to the southeast by South America and the Car ...
).


History

The first gasoline pump was invented and sold by
Sylvanus Bowser Sylvanus Freelove Bowser (August 8, 1854October 3, 1938) was an American inventor who is widely credited with inventing the automobile fuel pump. Bowser Avenue in his hometown of Fort Wayne, Indiana is named after him. Bowser marketed his paten ...
in Fort Wayne, Indiana on September 5, 1885, pre-dating the automobile industry- It was commonly used to dispense the kerosene used in lamps and stoves. He later improved upon the pump by adding safety measures, and by adding a hose to directly dispense fuel into automobiles. For a while, the term ''bowser'' was used to refer to a vertical gasoline pump. In the United States this term is now only used for trucks that carry and dispense fuel to large aircraft at airports, but it is still used sometimes in Australia and New Zealand. The first gasoline pump was patented by Norwegian John J. Tokheim in 1901. The Tokheim pump was named for him. Fuel retail industry giant OPW (a Dover company) acquired Tokheim in 2016. Many early gasoline pumps had a calibrated glass cylinder on top. The desired quantity of fuel was pumped up into the cylinder as indicated by the calibration. Then the pumping was stopped and the gasoline was let out into the customer's tank by gravity. When metering pumps came into use, a small glass globe with a turbine inside replaced the measuring cylinder to show the customer that gasoline really was flowing into the tank.


Design

A modern gasoline pump is divided into two main parts â€“ an electronic "head" containing an
embedded computer An embedded system is a computer system—a combination of a computer processor, computer memory, and input/output peripheral devices—that has a dedicated function within a larger mechanical or electronic system. It is ''embedded'' as ...
to control the action of the pump, drive the pump's displays, and communicate to an indoor sales system; and a mechanical section which (in a self-contained unit) has an electric motor, pumping unit, meters, pulsers and valves to physically pump and control the fuel flow. In some cases the actual pump may be sealed and immersed inside the fuel tanks on a site, in which case it is known as a submersible pump. In general, submersible solutions in Europe are installed in hotter countries, where suction pumps may have problems overcoming
cavitation Cavitation is a phenomenon in which the static pressure of a liquid reduces to below the liquid's vapour pressure, leading to the formation of small vapor-filled cavities in the liquid. When subjected to higher pressure, these cavities, cal ...
with warm fuels or when the distance from tank to pump is longer than a suction pump can manage. In modern pumps, the major variations are in the number of hoses or grades they can dispense, the physical shape, and additional hardware for services such as pay at the pump and attendant tag readers. Light passenger vehicles pump up to about per minute (the United States limits this to per minute); pumps serving trucks and other large vehicles have a higher flow rate, up to per minute in the UK and in the US. This flow rate is based on the diameter of the vehicle's fuel filling pipe, which limits flow to these amounts. Airline refueling can reach per minute. Higher flow rates may overload the vapor recovery system in vehicles equipped with enhanced evaporative emissions controls (required since 1996 in the US), causing excess vapor emissions, and may present a safety hazard. Historically, gasoline pumps had a very wide range of designs to solve the mechanical problems of pumping, reliable measurement, safety, and aesthetics. This has led to some popularity in collecting antique dispensers, especially in the US.


Fuel nozzles

Nozzles are attached to the pump with flexible hoses, so they can reach the vehicle's filler inlet. The hoses are robust to survive heavy wear and tear, including exposure to weather and being driven over, and are often attached using heavy spring or coil arrangements to provide additional strength. A breakaway valve is also fitted to the hose so that the nozzle and hose will detach and fuel flow stop if a motorist drives off with the nozzle still in the filler. Nozzles are usually color-coded to indicate which grade of fuel they dispense, but the color-coding differs between countries and even retailers. For example, a black hose and handle in the UK indicate that the fuel dispensed is diesel, and a green dispenser indicates unleaded fuel; the reverse is common in the US.


Misfueling

Some nozzles are designed to prevent the motorist selecting the wrong fuel. The nozzle on diesel pumps is supposed to be larger so that it cannot fit into the filler pipe on a vehicle tank designed for gasoline. However, the larger diameter diesel nozzles are not an actual requirement, and many diesel pumps have been fitted with standard gasoline nozzles. Also, the nozzle for leaded gasoline is wider than for unleaded, and the fill pipe on vehicles designed for unleaded-only was made narrower to prevent misfueling. Some diesel fuel tanks are designed to prevent the wrong type of nozzle from being used.


Blending

In some countries, pumps can mix two fuel products together before dispensing; this is referred to as blending or mixing. Typical usages are in a "mix" pump to add oil to petrol for two-stroke motorcycles, to produce an intermediate
octane rating An octane rating, or octane number, is a standard measure of a fuel's ability to withstand compression in an internal combustion engine without detonating. The higher the octane number, the more compression the fuel can withstand before detonating ...
from separate high and low octane fuels, or to blend hydrogen and compressed natural gas (
HCNG HCNG or H2CNG (hydrogen compressed natural gas) is a mixture of compressed natural gas and 4–9 percent hydrogen by energy. It may be used as a fuel gas for internal combustion engines and home appliances. (regarding the acronyms in the above emi ...
). Retailers benefit by offering three grades of fuel while only having to stock two. This frees up both working capital and tank capacity and improves fuel turnover.


Flow measurement

The equipment must accurately measure the amount of fuel pumped.
Flow measurement Flow measurement is the quantification of bulk fluid movement. Flow can be measured in a variety of ways. The common types of flowmeters with industrial applications are listed below: * a) Obstruction type (differential pressure or variable area) ...
is almost always done by a 4 stroke piston meter connected to an electronic encoder. In older gasoline pumps, the meter is physically coupled to reeled numerical displays (moving wheels or cylinders with numbers on the side), while newer pumps turn the meter's movement into electrical pulses using a rotary encoder.


Metrology


Gasoline

Gasoline is difficult to sell in a fair and consistent manner by volumetric units. It expands and contracts significantly as its temperature changes. Its coefficient of thermal expansion at 20 Â°C is about 4.5 times that of water. In the US, the National Institute of Standards and Technology (NIST) specifies the accuracy of the measurements in Handbook 44, though states set their own legal standards. The standard accuracy is 0.3%, meaning that a purchase may actually deliver between . The reference temperature for gasoline volume measurement is 60 Â°F or 15 Â°C. Ten gallons of gasoline at that temperature expands to about at and contracts to about at . Each of the three volumes represents the same theoretical amount of energy. In one sense, a given volume of gasoline purchased at 30 Â°F has about 3.2% more potential energy than the same volume purchased at 85 Â°F. Most gasoline is stored in tanks underneath the filling station. Modern tanks are non-metallic and sealed to stop leaks. Some have double walls or other structures that provide a side benefit of thermal insulation while pursuing the main goal of keeping gasoline out of the soil around the tank. So while the air temperature can easily vary between , the gasoline warms or cools much more slowly, especially underground, as deep soil temperature tends to remain in a narrow range throughout the year, regardless of air temperature. Temperature compensation is common at the wholesale level in the United States and most other countries. At the retail level, Canada has converted to automatic temperature compensation, and the UK is converting, but the United States has not converted. Automatic temperature compensation, known as Standard Temperature Accounting in the UK, may add a tiny amount of additional uncertainty to the measurement of about 0.1%. There are far fewer retail outlets for gasoline in the US today than there were in 1980. Larger outlets sell gasoline rapidly, as much as in a single day, even in remote places. Most finished product gasoline is delivered in 8,000- to 16,000-gallon tank trucks, so two deliveries in a 24-hour period are common. Gasoline spends so little time in the retail sales system that its temperature at the point of sale does not vary significantly from winter to summer or by region. Canada has lower overall population densities and geographically larger gasoline distribution systems, compared with the United States. Temperature compensation at the retail level improves the fairness under those conditions. In the United States, each state has its own Department of Weights and Measure, with the authority to perform all testing and certification, issuing fines for non-compliance. For example, in 2007 Arizona found that 9% of all pumps were off by at least 2.5% (the threshold for fines), evenly split between overcounting and undercounting fuel. In many jurisdictions, regular required inspections are conducted to ensure the accuracy of gasoline pumps. For example, the Florida Department of Agriculture and Consumer Services conducts regular tests of calibration and fuel quality at individual dispensers. The department also conducts random undercover inspections using specially designed vehicles that can check the accuracy of the dispensers. The department issues correction required notices to stations with pumps found to be inaccurate. Most other US states conduct similar inspections. In Canada, inspections are regularly conducted by the federal government agency Measurement Canada. Inspection dates and test results are required, by law, to be displayed to consumers on a sticker on gasoline pumps. Under the 2011 Fairness at the Pumps Act, a vendor with a modified or poorly maintained dispenser can be fined up to $50,000. However, virtually all pumps that fail inspection in Canada do so for general calibration errors caused by use over time. Intentional modification for the purpose of deceiving consumers is extremely rare, as are prosecutions.


Hydrogen

Hydrogen fuel dispensers in use on
hydrogen stations A hydrogen station is a storage or filling station for Hydrogen fuel, Hydrogen. The hydrogen is dispensed by weight. There are two filling pressures in common use. H70 or 700 bar, and the older standard H35 or 350 bar. As of 2021 around 550 fillin ...
dispense by the kilogram. In the US, the National Institute of Standards and Technology (NIST) specifies in Handbook 44 that the tolerance of the measurements is to be 2.0%. Worldwide regulations are discussed under OIML R 139 ( compressed hydrogen). Hydrogen pumps may be regulated under terms drawn from an industry technical standard,
SAE SAE or Sae may refer to: Science and technology : * Selective area epitaxy, local growth of epitaxial layer through a patterned dielectric mask deposited on a semiconductor substrate * Serious adverse event, in a clinical trial * Simultaneous Auth ...
J2601.


Communications components

Technology for communicating with gasoline pumps from a
point of sale The point of sale (POS) or point of purchase (POP) is the time and place at which a retail transaction is completed. At the point of sale, the merchant calculates the amount owed by the customer, indicates that amount, may prepare an invoice f ...
or other controller varies widely, involving a variety of hardware ( RS-485, RS-422, current loop, and others) and proprietary software protocols. In the past, this gave pump manufacturers vendor lock-in for their own point-of-sale systems, since only they understood the protocols. An effort to standardize in the 1990s resulted in the International Forecourt Standards Forum, which has had considerable success in Europe, but less elsewhere. By October 2017, all US gasoline pumps with credit card readers had to support EMV payment. A year before this rule came into force, a third of 750,000 pumps needed upgrading at a cost of $6,000 to $17,000 each plus the cost of new EPOS hardware and software. With some software not expected to be ready, some fleet cards not having chip technology available in time, not enough technicians for the installations, and many businesses unable to afford the upgrade, it was predicted the conversion would take until 2021.


Automatic cut-off

The shut-off valve was invented in
Olean, New York Olean ( ) is a city in Cattaraugus County, New York, United States. Olean is the largest city in Cattaraugus County and serves as its financial, business, transportation and entertainment center. It is one of the principal cities of the Southern ...
, in 1939 by Richard C. Corson. At a loading dock at the Socony-Vacuum Oil Company, Corson observed a worker filling a barrel with gasoline and thought it inefficient. The sound of a toilet flushing later gave him the idea for a "butterfly float." After developing a prototype with his assistant, Paul Wenke, Corson gave the suggestion to the company who later filed for a patent in his name. The initial intent of the device was to "allow a person to fill more than one barrel
f gasoline F, or f, is the sixth Letter (alphabet), letter in the Latin alphabet, used in the English alphabet, modern English alphabet, the alphabets of other western European languages and others worldwide. Its name in English is English alphabet#Let ...
at the same time." This mechanism eventually developed into the modern gasoline pump cut-off valve. Most modern pumps have an automatic cut-off feature that stops the flow when the tank is full. This is done with an auxiliary sensing tube running from just inside the mouth of the nozzle to a Venturi pump in the pump handle. A mechanical valve in the pump handle detects a change of pressure and closes, preventing the flow of fuel.


Other components

A modern fuel pump will often contain control equipment for the vapor recovery system, which prevents gasoline vapor from escaping to the air. In the UK, for example, any new forecourt with a predicted throughput in excess of 500 m3 per month is required to have active vapor recovery installed.


Early designs

File:Petrol bowser Gundagai.jpg, Restored petrol bowser, Gundagai, Australia File:Zapfsäule BP Wien.jpg, Fuel pump in Vienna, Austria. File:Ömossa 31.jpg, A 1991 photograph of a fuel pump in Ömossa village, Kristinestad, Finland. File:Petrol Pump, Quillan, France.jpg, Antique fuel pump in Quillan, France. File:Historische Zapfsaeule.jpg, Antique diesel fuel pump located at Roscheider Hof Open Air Museum, Konz, Germany. File:Verschiedene Zapfsäulen Deutsches Museum.jpg, Display of various antique fuel pumps at Deutsches Museum in Munich, Germany. File:Alte Zapfsäulen 1X7A7980.jpg, Display of various antique fuel pumps at Retro Classics 2018 in
Stuttgart Stuttgart (; Swabian: ; ) is the capital and largest city of the German state of Baden-Württemberg. It is located on the Neckar river in a fertile valley known as the ''Stuttgarter Kessel'' (Stuttgart Cauldron) and lies an hour from the ...
, Germany. File:Old-Gas-Pumps.jpg, Old Soviet Union fuel pumps. File:G-Morcomb's Service Station Gas Pumps.jpg, Gasoline pumps once used at the historic Morcomb's Service Station in
Glendale, Arizona Glendale () is a city in Maricopa County, Arizona, Maricopa County, Arizona, United States, located approximately northwest of Downtown Phoenix. As of the 2020 United States census, 2020 census, it had a population of 248,325. History In the la ...
. Included is a 1918 Visi Bowl pump (left) File:MobilgasPumpsAntique09162007.JPG, Antique "
Mobil Mobil is a petroleum brand owned and operated by American oil and gas corporation ExxonMobil. The brand was formerly owned and operated by an oil and gas corporation of the same name, which itself merged with Exxon to form ExxonMobil in 1999. ...
gas" pumps, manufactured by Tokheim, located in Wilton, Connecticut. File:Savannah Georgia gas_pump.jpg, Antique gasoline pump from Savannah, Georgia. File:SoulsbyServiceStation MtOliveIL.jpg, Two types of Shell gasoline pumps at Soulsby Service Station in Mount Olive, Illinois. File:Old_Gas_Pumps_at_2012_GMAS.jpg, Four old-fashioned gasoline pumps at the 2012
Greater Milwaukee Auto Show Greater may refer to: * Greatness, the state of being great *Greater than, in inequality * ''Greater'' (film), a 2016 American film * Greater (flamingo), the oldest flamingo on record * "Greater" (song), by MercyMe, 2014 * Greater Bank, an Austra ...
.


Regulation

Since gasoline pumps are the focal point of distributing fuel to the general public, and fuel is a hazardous substance, they are subject to stringent requirements regarding safety, accuracy and security. The exact details differ between jurisdictions and can depend to some extent on politics. For example, in countries fighting corruption, such as Mexico, gasoline pumps may be more stringently monitored by government officials, to detect attempts to defraud customers. Typically, individual pumps must be certified for operation after installation by a weights and measures inspector, who tests that the pump displays the same amount that it dispenses. In Taiwan, continuous fuel flow is not allowed for self service pumps; the driver must grip the nozzle until the desired amount of fuel has been delivered or until the shutoff switch is triggered. This is also the case in Australia and the UK.


See also

*
Fast fuel system A refueling Fast Fill System allows speedy and safe refueling for many types of equipment. This includes mining, heavy construction, busses and railroad. Most larger earthmoving and mining vehicles with diesel fuel tanks over are equipped with a re ...
*
Electric car charger A charging station, also known as a charge point or electric vehicle supply equipment (EVSE), is a piece of equipment that supplies electrical power for charging plug-in electric vehicles (including electric cars, electric trucks, electric ...
*
Cascade storage system A cascade filling system is a high-pressure gas cylinder storage system that is used for the refilling of smaller compressed gas cylinders. In some applications, each of the large cylinders is filled by a compressor, otherwise they may be filled ...
* HCNG dispenser *
Fisogni Museum The Fisogni Museum of the petrol station (in the past also SIRM Museum or Ormad Valseveso Museum), in Tradate, Italy, is a museum about gas pumps, Filling station, gas stations and petroliana, founded by Guido Fisogni in 1966. With its 8000 piec ...


References


External links


How does a gas pump know to shut itself off?
from ''The Straight Dope'' {{Authority control Pumps Petroleum infrastructure American inventions Filling stations 19th-century inventions