Consideration of materials used
Factors affecting the type and amount of insulation to use in a building include: * Thermal conductivity * Moisture sensitivity * Compressive strength * Ease of installation * Durability – resistance to degradation from compression, moisture, decomposition, etc. * Ease of replacement at end of life * Cost effectiveness * Toxicity * Flammability * Environmental impact and sustainability Considerations regarding building and climate: * The average climate conditions in the geographical area the building is located * The temperature the building is used at Often a combination of materials is used to achieve an optimum solution and there are products which combine different types of insulation into a single form.Spray foam
Spray foam is a type of insulation that is sprayed in place through a gun. Polyurethane and isocyanate foams are applied as a two-component mixture that comes together at the tip of a gun, and forms an expanding foam.Advantages
* Blocks airflow by expanding & sealing off leaks, gaps and penetrations. (This can also keep out bugs or other vermin) * Can serve as aDisadvantages
* The cost can be high compared to traditional insulation. * Most foams, with the exception of cementitious foams, release toxic fumes when they burn. * According to the US Environmental Protection Agency, there is insufficient data to accurately assess the potential for exposures to the toxic and environmentally harmful isocyanates which constitute 50% of the foam material. * Depending on usage and building codes and environment, most foams require protection with a thermal barrier such as drywall on the interior of a house. For example, a 15-minute fire rating may be required. * Can shrink slightly while curing if not applied on a substrate heated to manufacturer's recommended temperature. * AlthoughAdvantages of closed-cell over open-cell foams
* Open-cell foam is porous, allowing water vapor and liquid water to penetrate the insulation. Closed-cell foam is non-porous, and not moisture-penetrable, thereby effectively forming a semi-permeable vapor barrier. (N.b., vapor barriers are usually required by the Building Codes, regardless of the type of insulation used. Check with the local authorities to find out the requirements for your area.) * Closed-cell foams are superior insulators. While open-cell foams typically have R-values of 3 to 4 per inch (RSI-0.53 to RSI-0.70 per inch), closed-cell foams can attain R-values of 5 to 8 per inch (RSI-0.88 to RSI-1.41 per inch). This is important if space is limited, because it allows a thinner layer of insulation to be used. For example, a 1-inch layer of closed-cell foam provides about the same insulation factor as 2 inches of open-cell foam. * Closed-cell foam is very strong, and structurally reinforces the insulated surface. By contrast, open-cell foam is soft when cured, with little structural strength. * Open-cell foam requires trimming after installation, and disposal of the waste material. Unlike open-cell foam, closed-cell foam rarely requires any trimming, with little or no waste.Advantages of open-cell over closed-cell foams
* Open cell foams will allow timber to breathe. * Open cell foams are incredibly effective as a sound barrier, having about twice the sound resistance in normal frequency ranges as closed-cell foam. * Open cell foams provide a better economical yield. * Open cell foams often have a low exothermic reaction temperature; will not harm coatings on electrical wiring, plumbing or other building components.Types
;Insulating concrete forms
Insulating concrete forms (ICFs) are stay-in-place formwork made from insulating materials to build energy-efficient, cast-in-place, reinforced concrete walls.Rigid panels
Rigid panel insulation, also known as continuous insulation can be made from foam plastics such as polyisocyanurate orStructural insulated panels
Advantages
* Strong. Able to bear loads, including external loads from precipitation and wind. * Faster construction than stick-built house. Less lumber required. * Insulate acoustically. * Impermeable to moisture. * Can truck prefabricated panels to construction site and assemble on site. * Create shell of solid insulation around house, while reducing bypasses common with stick-frame construction. The result is an inherently energy-efficient house. * Do not use formaldehyde, CFCs, or HCFCs in manufacturing. * True R-values and lower energy costs.Disadvantages
* More expensive than other types of insulation. * Thermal bridging at splines and lumber fastening points unless a thermally broken spline is used (insulated lumber).Fiberglass batts and blankets (glass wool)
Batts are precut, whereas blankets are available in continuous rolls. Compressing the material reduces its effectiveness. Cutting it to accommodate electrical boxes and other obstructions allows air a free path to cross through the wall cavity. One can install batts in two layers across an unfinished attic floor, perpendicular to each other, for increased effectiveness at preventingTypes
* Rock and slag wool. Usually made from rock (basalt, diabase) or iron ore blast furnace slag. Some rock wool contains recycled glass. Nonflammable. * Fiberglass. Made from molten glass, usually with 20% to 30% recycled industrial waste and post-consumer content. Nonflammable, except for the facing (if present). Sometimes, the manufacturer modifies the facing so that it is fire-resistant. Some fiberglass is unfaced, some is paper-faced with a thin layer of asphalt, and some is foil-faced. Paper-faced batts are vapor retarders, not vapor barriers. Foil-faced batts are vapor barriers. The vapor barrier must be installed toward the warm side. * High-density fiberglass * Plastic fiber, usually made from recycled plastic. Does not cause irritation like fiberglass, but more difficult to cut than fiberglass. Not used in US. Flammable, but treated with fire-retardant.Natural fiber
Natural fiber insulations, treated as necessary with low toxicity fire and insect retardants, are available in Europe : Natural fiber insulations can be used loose as granulats or formed into flexible or semi-rigid panels and rigid panels using a binder (mostly synthetic such as polyester, polyurethane or polyolefin). The binder material can be new or recycled. Examples include cork, cotton, recycled tissue/clothes,Cork insulation Board
During the 2nd century C.100 -C.200 it was the first time human civilisation was introduced to material of cork, and it was only until the 19th century when cork was widely used leading to major industrial production. Cork, which is harvested from the Oak trees generally found in Portugal, Spain and other Mediterranean countries. When a tree reaches 20 to 35 years old, it can be harvested in 10-year intervals for more than 200 years. Oak bark has a lattice-like molecular structure filled with millions of air bubbles giving the bark resilience, elasticity, thermal insulating, acoustic dampening, and shock absorbing properties. The material is sustainable, reusable and recyclable. There are two types of cork, the pure cork, which is preferable due to its natural bonding properties, and the agglomeration cork. The pure cork is made by processes of heating and steaming whereby cork granulates are molded into a block. The natural resin of the cork acts as a bonding agent. An artificial bonding agent is required for the production of agglomeration cork. Cork is typically used for acoustic and thermal insulation within walls, floors, ceilings and facades. A natural fire retardant, thermal insulating cork board is also non-allergenic, simple-to-install and a considerably safer substitute to fiber and plastic based insulation. Notable challenges with cork include difficulty in maintenance and cleaning especially if the material is exposed to heavy use such as insulation for flooring. Minor damages to cork surface can make the material more prone to staining.Sheep's wool insulation
Sheep's wool insulation is a very efficient thermal insulator with a similar performance to fiberglass, approximately R13-R16 for a 4-inch-thick layer. Sheep's wool has no reduction in performance even when condensation is present, but its fire retarding treatment can deteriorate through repeated moisture. It is made from the waste wool that the carpet and textile industries reject, and is available in both rolls and batts for both thermal and acoustic insulation of housing and commercial buildings. Wool is capable of absorbing as much as 40% of its own weight in condensation while remaining dry to the touch. As wool absorbs moisture it heats up and therefore reduces the risk of condensation. It has the unique ability to absorb VOC gases such as formaldehyde, nitrogen dioxide, sulphur dioxide and lock them up permanently. Sheep's wool insulation has a long lifetime due to the natural crimp in the fibre, endurance testing has shown it has a life expectancy of over 100 years.Wood fiber
Wood fiber insulation is available as loose fill, flexible batts and rigid panels for all thermal and sound insulation uses. It can be used as internal insulation : between studs, joists or ceiling rafters, under timber floors to reduce sound transmittance, against masonry walls or externally : using a rain screen cladding or roofing, or directly plastered/rendered, over timber rafters or studs or masonry structures as external insulation to reduce thermal bridges. There are two manufacturing processes: * a wet process similar to pulp mills in which the fibers are softened and under heat and pressure the ligin in the fibres is used to create boards. The boards are limited to approximately 25 mm thickness; thicker boards are made by gluing (with modified starch or PVA wood glue). Additives such as latex or bitumen are added to increase water resistance. * a dry process where a synthetic binder such as pet (polyester melted bond), polyolefin or polyurethane is added and the boards/batts pressed to different densities to make flexible batts or rigid boards.Cotton batts
Cotton insulation is increasing in popularity as an environmentally preferable option for insulation. It has an R-value of around 3.7 (RSI-0.65), equivalent to the median value for fiberglass batts. The cotton is primarily recycled industrial scrap, providing a sustainability benefit. The batts do not use the toxic formaldehyde backing found in fiberglass, and the manufacture is nowhere near as energy intensive as the mining and production process required for fiberglass. Boric acid is used as a flame retardant. A small quantity of polyolefin is melted as an adhesive to bind the product together (and is preferable to formaldehyde adhesives). Installation is similar to fiberglass, without the need for a respirator but requiring some additional time to cut the material. Cotton insulation costs about 10-20% more than fiberglass insulation. As with any batt insulation, proper installation is important to ensure high energy efficiency.Advantages
* Equivalent R-Value to typical fiberglass batts * Recycled content, no formaldehyde or other toxic substances, and very low toxicity during manufacture (only from the polyolefin) * May help qualify for LEED or similar environmental building certification programs * Fibers do not cause itchiness, no cancer risk from airborne fibersDisadvantages
* Difficult to cut. Some installers may charge a slightly higher cost for installation as compared to other batts. This does not affect the effectiveness of the insulation, but may require choosing an installer more carefully, as any batt should be cut to fit the cavity well. * Even with proper installation, batts do not completely seal the cavity against air movement (as with cellulose or expanding foam). * Still requires a vapor retarder or barrier (unlike cellulose) * May be hard to dry if a leak allows excessive moisture into the insulated cavityLoose-fill (including cellulose)
Loose-fill materials can be blown into attics, finished wall cavities, and hard-to-reach areas. They are ideal for these tasks because they conform to spaces and fill in the nooks and crannies. They can also be sprayed in place, usually with water-based adhesives. Many types are made of recycled materials (a type of cellulose) and are relatively inexpensive. General procedure for retrofits in walls: * Drill holes in wall with hole saw, taking firestops, plumbing pipes, and other obstructions into account. It may be desirable to drill two holes in each wall cavity/joist section, one at the bottom and a second at the top for both verification and top-off. * Pump loose fill into wall cavity, gradually pulling the hose up as the cavity fills. * Cap the holes in the wall.Advantages
* Cellulose insulation is environmentally preferable (80% recycled newspaper) and safe. It has a high recycled content and less risk to the installer than fiberglass (loose fill or batts). * R-Value 3.4 – 3.8 (RSI-0.60 – 0.67) per inch (imperial units) * Loose fill insulation fills the wall cavity better than batts. Wet-spray applications typically seal even better than dry-spray. * Class I fire safety rating * No formaldehyde-based binders * Not made from petrochemicals nor chemicals with a high toxicityDisadvantages
* Weight may cause ceilings to sag if the material is very heavy. Professional installers know how to avoid this, and typical sheet rock is fine when dense-packed. * Will settle over time, losing some of its effectiveness. Unscrupulous contractors may "fluff" insulation using fewer bags than optimal for a desired R-value. Dry-spray (but not wet-spray) cellulose can settle 20% of its original volume. However, the expected settling is included in the stated R-Value. The dense-pack dry installation reduces settling and increases R-value. * R-values stated on packaging are based on laboratory conditions; air infiltration can significantly reduce effectiveness, particularly for fiberglass loose fill. Cellulose inhibits convection more effectively. In general, loose fill is seen as being better at reducing the presence of gaps in insulation than batts, as the cavity is sealed more carefully. Air infiltration through the insulating material itself is not studied well, but would be lower for wet-spray insulations such as wet-spray cellulose. * May absorb moisture.Types
* Rock and slag wool, also known as mineral wool or mineral fiber. Made from rock (basalt, diabase), iron ore blast furnace slag, or recycled glass. Nonflammable. More resistant to airflow than fiberglass. Clumps and loses effectiveness when moist or wet, but does not absorb much moisture, and regains effectiveness once dried. Older mineral wool can contain asbestos, but normally this is in trace amounts. * Cellulose insulation. Cellulose, is denser and more resistant to air flow than fiberglass. Persistent moisture will weaken aluminium sulphate flame-retardants in cellulose (which are sometimes used in the US). However, borate fire retardants (used primarily in Australia and commonly in the US) have been in use for more than 30 years and are not affected by moisture in any way. Dense-pack cellulose is highly resistant to air infiltration and is either installed into an open wall cavity using nets or temporary frames, or is retrofitted into finished walls. However, dense-pack cellulose blocks, but does not permanently seal, bypasses, in the way a closed-cell spray foam would. Furthermore, as with batts and blankets, warm, moist air will still pass through, unless there is a continuous near-perfect vapor barrier. * Wet-spray cellulose insulation is similar to loose-fill insulation, but is applied with a small quantity of water to help the cellulose bind to the inside of open wall cavities, and to make the cellulose more resistant to settling. Spray application provides even better protection against air infiltration and improves wall rigidity. It also allows application on sloped walls, attics, and similar spaces. Wet-spray is best for new construction, as the wall must be allowed to dry completely before sealing with drywall (a moisture meter is recommended). Moist-spray (also called stabilized) cellulose uses less water to speed up drying time. * Fiberglass. Usually pink, yellow, or white. Loses effectiveness when moist or wet, but does not absorb much water. Nonflammable. See Health effects of fiberglass. * Natural insulations such as granulated cork, hemp fibres, grains, all which can be treated with a low toxicity fire and insect retardants * Vermiculite. Generally gray or brown. * Perlite. Generally white or yellow. * Cotton, wool, hemp, corn cobs, strawdust and other harvested natural materials. Not common. * Granulated cork. Cork is as good an insulator as foam. It does not absorb water as it consists of closed cells. Resists fire. Used in Europe. * Most plant based insulations such as wood chips, wood fiber, sawdust, redwood bark, hemlock fiber, balsa wood, hemp fiber, flax fiber, etc. are hygroscopic. Wood absorbs water, which reduces its effectiveness as a thermal insulator. In the presence of moisture, wood is susceptible to mold, mildew, and rot. Careful design of wall, roof and floor systems as done in Europe avoid these problems which are due to poor design.Regulations
US regulatory standards for cellulose insulation * 16 CFR Part 1209 (Consumer Products Safety Commission, or CPSC) – covers settled density, corrosiveness, critical radiant flux, and smoldering combustion. * ASTM Standard C-739 – loose-fill cellulose insulation – covers all factors of the CPSC regulation and five additional characteristics, R-value, starch content, moisture absorption, odor, and resistance to fungus growth. * ASTM Standard C-1149 – Industry standard for self-supported spray-applied cellulose insulation for exposed or wall cavity application – covers density, R-value, surface burning, adhesive strength, smoldering combustion, fungi resistance, corrosion, moisture vapor absorption, odor, flame resistance permanency (no test exists for this characteristic), substrate deflection (for exposed application products), and air erosion (for exposed application products). * 16 CFR Part 460 – (Federal Trade Commission regulation) commonly known as the "R-Value Rule," intended to eliminate misleading insulation marketing claims and ensure publication of accurate R-Value and coverage data.Aerogels
Skylights, solariums and other special applications may useStraw bales
The use of highly compressedReflective insulation and radiant barriers
Reflective insulation and radiant barriers reduce the radiation of heat to or from the surface of a material. Radiant barriers will reflect radiant energy. A radiant barrier by itself will not affect heat conducted through the material by direct contact or heat transferred by moist air rising or convection. For this reason, trying to associate R-values with radiant barriers is difficult and inappropriate. The R-value test measures heat transfer through the material, not to or from its surface. There is no standard test designed to measure the reflection of radiated heat energy alone. Radiated heat is a significant means of heat transfer; the sun's heat arrives by radiating through space and not by conduction or convection. At night the absence of heat (i.e. cold) is the exact same phenomenon, with the heat radiating described mathematically as the linear opposite. Radiant barriers prevent radiant heat transfer equally in both directions. However, heat flow to and from surfaces also occurs via convection, which in some geometries is different in different directions. Reflective aluminum foil is the most common material used as a radiant barrier. It has no significant mass to absorb and retain heat. It also has very low emittance values "E-values" (typically 0.03 compared to 0.90 for most bulk insulation) which significantly reduces heat transfer by radiation.Types of radiant barriers
* Foil or "reflective foil laminate"s (RFL). * Foil-faced polyurethane or foil-faced polyisocyanurate panels. * Foil-faced polystyrene. This laminated, high density EPS is more flexible than rigid panels, works as a vapor barrier, and works as a thermal break. Uses include the underside of roof sheathing, ceilings, and on walls. For best results, this should not be used as a cavity fill type insulation. * Foil-backed bubble pack. This is thin, more flexible than rigid panels, works as a vapor barrier, and resembles plastic bubble wrap with aluminum foil on both sides. Often used on cold pipes, cold ducts, and the underside of roof sheathing. * Light-colored roof shingles and reflective paint. Often calledReflective Insulation
Insulation is a barrier material to resist/reduce substance (water, vapor, etc. ) /energy (sound, heat, electric, etc.) to transfer from one side to another. Heat/ Thermal Insulation is a barrier material to resist / block / reflect the heat energy (either one or more of the Conduction, Convection or Radiation) to transfer from one side to another. Reflective Insulation is one of the Heat/Thermal Insulation to reflect Radiation Heat (Radiant Heat) transfer from one side to another due to the reflective surface (or low emittance). There are a lot of definitions about “Thermal/Heat Insulation” and the common misinterpretation of “Thermal/Heat Insulation” = “Bulk/Mass/Batt Insulation” which is actually uses to resist Conduction Heat Transfer with certain "R-Value". As such Materials reflecting Radiant Heat with negligible “R-Value” should also be classified as “Thermal/ Heat Insulation”. Thus Reflective Insulation = Radiant BarrierAdvantages
* Very effective in warmer climates * No change in thermal performance over time due to compaction, disintegration or moisture absorption * Thin sheets takes up less room than bulk insulation * Can act as a vapor barriers * Non-toxic/non-carcinogenic * Will not mold or mildew * Radon retarder, will limit radon penetration through the floorDisadvantages
* Must be combined with other types of insulation in very cold climates * May result in an electrical safety hazard where the foil comes into contact with faulty electrical wiringHazardous and discontinued insulation
Certain forms of insulation used in the past are now no longer used because of recognized health risks.Urea-formaldehyde foam (UFFI) and panels
Urea-formaldehyde insulation releases poisonous formaldehyde gas, causing indoor air quality problems. The chemical bond between the urea and formaldehyde is weak, resulting in degradation of the foam cells and emission of toxic formaldehyde gas into the home over time. Furthermore, some manufacturers used excess formaldehyde to ensure chemical bonding of all of the urea. Any leftover formaldehyde would escape after the mixing. Most states outlawed it in the early 1980s after dangers to building occupants were discovered. However emissions are highest when the urea-formaldehyde is new and decrease over time, so houses that have had urea-formaldehyde within their walls for years or decades do not require remediation. UFFI provides little mechanical strength, as the material is weak and brittle. Before its risks were recognized, it was used because it was a cheap, effective insulator with a high R-value and its open-cell structure was a goodAsbestos
Health and safety issues
Spray polyurethane foam (SPF)
All polyurethane foams are composed ofFiberglass
Fiberglass is the most common residential insulating material, and is usually applied as batts of insulation, pressed between studs. Health and safety issues include potential cancer risk from exposure to glass fibers, formaldehyde off-gassing from the backing/resin, use of petrochemicals in the resin, and the environmental health aspects of the production process. Green building practices shun Fiberglass insulation. The World Health Organization has declared fiber glass insulation as ''potentially'' carcinogenic (WHO, 1998). In October 2001, an international expert review by the International Agency for Research on Cancer (IARC) re-evaluated the 1988 IARC assessment of glass fibers and removedLoose-fill cellulose
Cellulose is 100% natural and 75–85% of it is made from recycled newsprint. Health issues (if any) appear to be minor, and most concerns around the flame retardants and mold potential seem to be misrepresentations. * Cellulose is classified by OSHA as a dust nuisance during installation, and the use of a dust mask is recommended. * Cellulose is treated with a flame retardant and insect repellent, usually boric acid and sometimes borax to resist insects and rodents. To humans, boric acid has a toxicity comparable to table salt. * Mold has been seen as a potential concern. However, according to the Cellulose Manufacturer's Association, "One thing that has not contributed to mold problems is the growing popularity of cellulose insulation among knowledgeable home owners who are interested in sustainable building practices and energy conservation. Mycology experts (mycology is the study of mold) are often quoted as saying: “Mold grows on cellulose.” They are referring to cellulose the generic material that forms the cell walls of all plants, not to cellulose insulation. Unfortunately, all too often this statement is taken to mean that cellulose insulation is exceptionally susceptible to mold contamination. In fact, due to its favorable moisture control characteristics and other factors associated with the manufacturing process relatively few cases of significant mold growth on cellulose insulation have been reported. All the widely publicized incidents of serious mold contamination of insulation have involved fiber insulation materials other than cellulose.". * Moisture is always a concern for homes, and the wet-spray application of cellulose may not be a good choice in particularly wet climates unless the insulation can be verified to be dry before drywall is added. In very wet climates the use of a moisture meter will ensure proper installation and eliminate any installation mold issues (almost any insulation that becomes and remains wet can in the future cause a mold issue). The dry-spray application is another option for very wet climates, allowing for a faster installation (though the wet-spray cellulose has an even higher R-value and can increase wall rigidity).US Health and Safety Partnership Program
In May 1999, the North American Insulation Manufacturers Association began implementing a comprehensive voluntary work practice partnership with the US Occupational Safety and Health Administration (OSHA). The program, known as the Health and Safety Partnership Program, or HSPP, promotes the safe handling and use of insulation materials and incorporates education and training for the manufacture, fabrication, installation and removal of fiber glass, rock wool and slag wool insulation products. (See health effects of fiberglass). (For authoritative and definitive information on fiber glass and rock and slag wool insulation, as well as the HSPP, consult the North American Insulation Manufacturers Association (NAIMASee also
*Notes
References
* U.S. Environmental Protection Agency and the US Department of Energy's Office of Building Technologies. * Loose-Fill Insulations, DOE/GO-10095-060, FS 140, Energy Efficiency and Renewable Energy Clearinghouse (EREC), May 1995. * Insulation Fact Sheet, US Department of Energy, update to be published 1996. Also available from EREC. * Lowe, Allen. "Insulation Update," The Southface Journal, 1995, No. 3. Southface Energy Institute, Atlanta, Georgia, US * ICAA Directory of Professional Insulation Contractors, 1996, and A Plan to Stop Fluffing and Cheating of Loose-Fill Insulation in Attics, Insulation Contractors Association of America, 1321 Duke St., #303, Alexandria, VA 22314, (703)739-0356. * US DOE Consumer Energy Information. * Insulation Information for Nebraska Homeowners, NF 91–40. * Article in Daily Freeman, Thursday, 8 September 2005, Kingston, New York, US * TM 5-852-6 AFR 88–19, Volume 6 (Army Corps of Engineers publication). * CenterPoint Energy Customer Relations.