Fail-secure
   HOME

TheInfoList



OR:

In engineering, a fail-safe is a design feature or practice that in the event of a specific type of
failure Failure is the state or condition of not meeting a desirable or intended objective (goal), objective, and may be viewed as the opposite of Success (concept), success. The criteria for failure depends on context, and may be relative to a parti ...
, inherently responds in a way that will cause minimal or no harm to other equipment, to the environment or to people. Unlike inherent safety to a particular hazard, a system being "fail-safe" does not mean that failure is impossible or improbable, but rather that the system's design prevents or mitigates unsafe consequences of the system's failure. That is, if and when a "fail-safe" system fails, it remains at least as safe as it was before the failure. Since many types of failure are possible, failure mode and effects analysis is used to examine failure situations and recommend safety design and procedures. Some systems can never be made fail-safe, as continuous availability is needed. Redundancy, fault tolerance, or contingency plans are used for these situations (e.g. multiple independently controlled and fuel-fed engines).


Examples


Mechanical or physical

Examples include: *Roller-shutter fire doors that are activated by building alarm systems or local smoke detectors must close automatically when signaled regardless of power. In case of power outage the coiling fire door does not need to close, but must be capable of automatic closing when given a signal from the building alarm systems or smoke detectors. A temperature-sensitive
fusible link A fusible link is a mechanical or electrical safety device. They are used in fire sprinkler heads to activate the sprinkler in the presence of heat. They are used in automobile electrical systems as a fuse. Mechanical fusible link A mechanical ...
may be employed to hold the fire doors open against gravity or a closing spring. In case of fire, the link melts and releases the doors, and they close. *Some airport
baggage Baggage or luggage consists of bags, cases, and containers which hold a traveler's personal articles while the traveler is in transit. A modern traveler can be expected to have packages containing clothing, toiletries, small possessions, trip ...
cart A cart or dray (Australia and New Zealand) is a vehicle designed for transport, using two wheels and normally pulled by one or a pair of draught animals. A handcart is pulled or pushed by one or more people. It is different from the flatbed tr ...
s require that the person hold down a given cart's handbrake switch at all times; if the handbrake switch is released, the brake will activate, and assuming that all other portions of the braking system are working properly, the cart will stop. The handbrake-holding requirement thus both operates according to the principles of "fail-safety" and contributes to (but does not necessarily ensure) the fail-security of the system. This is an example of a '' dead man's switch''. * Lawnmowers and snow blowers have a hand-closed lever that must be held down at all times. If it is released, it stops the blade's or rotor's rotation. This also functions as a ''dead man's switch''. * Air brakes on railway trains and air brakes on trucks. The brakes are held in the "off" position by air pressure created in the brake system. Should a brake line split, or a carriage become de-coupled, the air pressure will be lost and the brakes applied, by springs in the case of trucks, or by a local air reservoir in trains. It is impossible to drive a truck with a serious leak in the air brake system. (Trucks may also employ wig wags to indicate low air pressure.) *Motorized gates – In case of power outage the gate can be pushed open by hand with no crank or key required. However, as this would allow virtually anyone to go through the gate, a ''fail-secure'' design is used: In a power outage, the gate can only be opened by a hand crank that is usually kept in a safe area or under lock and key. When such a gate provides vehicle access to homes, a fail-safe design is used, where the door opens to allow fire department access. *Safety valves – Various devices that operate with
fluid In physics, a fluid is a liquid, gas, or other material that continuously deforms (''flows'') under an applied shear stress, or external force. They have zero shear modulus, or, in simpler terms, are substances which cannot resist any shear ...
s use fuses or safety valves as fail-safe mechanisms. *A railway semaphore signal is specially designed so that, should the cable controlling the signal break, the arm returns to the "danger" position, preventing any trains passing the inoperative signal. *
Isolation valve An isolation valve is a valve in a fluid handling system that stops the flow of process media to a given location, usually for maintenance or safety purposes. They can also be used to provide flow logic (selecting one flow path versus another), an ...
s, and control valves, that are used for example in systems containing hazardous substances, can be designed to close upon loss of power, for example by spring force. This is known as fail-closed upon loss of power. *An elevator has brakes that are held off brake pads by the tension of the elevator cable. If the cable breaks, tension is lost and the brakes latch on the rails in the shaft, so that the elevator cabin does not fall. * Vehicle air conditioning – Defrost controls require vacuum for diverter damper operation for all functions except defrost. If vacuum fails, defrost is still available.


Electrical or electronic

Examples include: *Many devices are protected from short circuit by fuses, circuit breakers, or
current limiting Current limiting is the practice of imposing a limit on the current that may be delivered to a load to protect the circuit generating or transmitting the current from harmful effects due to a short-circuit or overload. The term "current limiting" is ...
circuits. The electrical interruption under overload conditions will prevent damage or destruction of wiring or circuit devices due to overheating. * Avionics using redundant systems to perform the same computation using three different systems. Different results indicate a fault in the system. * Drive-by-wire and fly-by-wire controls such as an Accelerator Position Sensor typically have two potentiometers which read in opposite directions, such that moving the control will result in one reading becoming higher, and the other generally equally lower. Mismatches between the two readings indicates a fault in the system, and the ECU can often deduce which of the two readings is faulty. * Traffic light controllers use a ''Conflict Monitor Unit'' to detect faults or conflicting signals and switch an intersection to an all flashing error signal, rather than displaying potentially dangerous conflicting signals, e.g. showing green in all directions. *The automatic protection of programs and/or processing systems when a
computer hardware Computer hardware includes the physical parts of a computer, such as the computer case, case, central processing unit (CPU), Random-access memory, random access memory (RAM), Computer monitor, monitor, Computer mouse, mouse, Computer keyboard, ...
or software failure is detected in a computer system. A classic example is a watchdog timer. See
Fail-safe (computer) Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of one or more faults within some of its components. If its operating quality decreases at all, the decrease is proportional to the ...
. *A
control operation In telecommunication, a control operation (control function) is an Instruction (computer science), operation that affects the recording, processing, transmission (telecommunications), transmission, or interpretation of data. Examples of control o ...
or function that prevents improper system functioning or catastrophic degradation in the event of
circuit Circuit may refer to: Science and technology Electrical engineering * Electrical circuit, a complete electrical network with a closed-loop giving a return path for current ** Analog circuit, uses continuous signal levels ** Balanced circu ...
malfunction or operator error; for example, the failsafe track circuit used to control railway block signals. The fact that a flashing amber is more permissive than a solid amber on many railway lines is a sign of a failsafe, as the relay, if not working, will revert to a more restrictive setting. *The iron pellet ballast on the
Bathyscaphe A bathyscaphe ( or ) is a free-diving self-propelled deep-sea submersible, consisting of a crew cabin similar to a bathysphere, but suspended below a float rather than from a surface cable, as in the classic bathysphere design. The float is fi ...
is dropped to allow the submarine to ascend. The ballast is held in place by electromagnets. If electrical power fails, the ballast is released, and the submarine then ascends to safety. *Many nuclear reactor designs have neutron absorbing control rods suspended by electromagnets. If the power fails, they drop under gravity into the core and shut down the chain reaction in seconds by absorbing the neutrons needed for fission to continue. *In industrial automation, alarm circuits are usually " normally closed". This ensures that in case of a wire break the alarm will be triggered. If the circuit were normally open, a wire failure would go undetected, while blocking actual alarm signals. *Analog sensors and modulating actuators can usually be installed and wired such that the circuit failure results in an out-of-bound reading – see current loop. For example, a potentiometer indicating pedal position might only travel from 20% to 80% of its full range, such that a cable break or short results in a 0% or 100% reading. *In control systems, critically important signals can be carried by a complementary pair of wires ( and ). Only states where the two signals are opposite (one is high, the other low) are valid. If both are high or both are low the control system knows that something is wrong with the sensor or connecting wiring. Simple failure modes (dead sensor, cut or unplugged wires) are thereby detected. An example would be a control system reading both the normally open (NO) and normally closed (NC) poles of a SPDT selector switch against common, and checking them for coherency before reacting to the input. *In HVAC control systems, actuators that control dampers and valves may be fail-safe, for example, to prevent coils from freezing or rooms from overheating. Older pneumatic actuators were inherently fail-safe because if the air pressure against the internal diaphragm failed, the built-in spring would push the actuator to its home position – of course the home position needed to be the "safe" position. Newer electrical and electronic actuators need additional components (springs or capacitors) to automatically drive the actuator to home position upon loss of electrical power. *
Programmable logic controller A programmable logic controller (PLC) or programmable controller is an industrial computer that has been ruggedized and adapted for the control of manufacturing processes, such as assembly lines, machines, robotic devices, or any activity tha ...
s (PLCs). To make a PLC fail-safe the system does not require energization to stop the drives associated. For example, usually, an emergency stop is a normally closed contact. In the event of a power failure this would remove the power directly from the coil and also the PLC input. Hence, a fail-safe system. *If a voltage regulator fails, it can destroy connected equipment. A
crowbar (circuit) A crowbar circuit is an electrical circuit used for preventing an overvoltage or surge condition of a power supply unit from damaging the circuits attached to the power supply. It operates by putting a short circuit or low resistance path across ...
prevents damage by short-circuiting the power supply as soon as it detects overvoltage.


Procedural safety

As well as physical devices and systems fail-safe procedures can be created so that if a procedure is not carried out or carried out incorrectly no dangerous action results. For example: *Spacecraft trajectory - During early Apollo program missions to the Moon, the spacecraft was put on a free return trajectory — if the engines had failed at
lunar orbit In astronomy, lunar orbit (also known as a selenocentric orbit) is the orbit of an object around the Moon. As used in the space program, this refers not to the orbit of the Moon about the Earth, but to orbits by spacecraft around the Moon. The ...
insertion, the craft would have safely coasted back to Earth. *The pilot of an aircraft landing on an
aircraft carrier An aircraft carrier is a warship that serves as a seagoing airbase, equipped with a full-length flight deck and facilities for carrying, arming, deploying, and recovering aircraft. Typically, it is the capital ship of a fleet, as it allows a ...
increases the throttle to full power at touchdown. If the
arresting wire An arresting gear, or arrestor gear, is a mechanical system used to rapidly acceleration, decelerate an aircraft as it landing, lands. Arresting gear on aircraft carriers is an essential component of naval aviation, and it is most commonly used ...
s fail to capture the aircraft, it is able to take off again; this is an example of ''fail-safe practice''. *In railway signalling signals which are not in active use for a train are required to be kept in the 'danger' position. The default position of every controlled absolute signal is therefore "danger", and therefore a positive action — setting signals to "clear" — is required before a train may pass. This practice also ensures that, in case of a fault in the signalling system, an incapacitated signalman, or the unexpected entry of a train, that a train will never be shown an erroneous "clear" signal. *Railroad engineers are instructed that a railway signal showing a confusing, contradictory or unfamiliar aspect (for example a colour light signal that has suffered an electrical failure and is showing no light at all) must be treated as showing "danger". In this way, the driver contributes to the fail-safety of the system.


Other terminology

Fail-safe ( foolproof) devices are also known as '' poka-yoke'' devices. ''Poka-yoke'', a Japanese term, was coined by Shigeo Shingo, a quality expert. "Safe to fail" refers to civil engineering designs such as the Room for the River project in Netherlands and the Thames Estuary 2100 Plan which incorporate flexible adaptation strategies or climate change adaptation which provide for, and limit, damage, should severe events such as 500-year floods occur.


Fail safe and fail secure

''Fail-safe'' and ''fail-secure'' are distinct concepts. ''Fail-safe'' means that a device will not endanger lives or property when it fails. ''Fail-secure,'' also called ''fail-closed,'' means that access or data will not fall into the wrong hands in a security failure. Sometimes the approaches suggest opposite solutions. For example, if a building catches fire, fail-safe systems would unlock doors to ensure quick escape and allow firefighters inside, while fail-secure would lock doors to prevent unauthorized access to the building. The opposite of ''fail-closed'' is called ''fail-open''.


Fail active operational

Fail active operational can be installed on systems that have a high degree of redundancy so that a single failure of any part of the system can be tolerated (fail active operational) and a second failure can be detected – at which point the system will turn itself off (uncouple, fail passive). One way of accomplishing this is to have three identical systems installed, and a control logic which detects discrepancies. An example for this are many aircraft systems, among them inertial navigation systems and pitot tubes.


Failsafe point

During the
Cold War The Cold War is a term commonly used to refer to a period of geopolitical tension between the United States and the Soviet Union and their respective allies, the Western Bloc and the Eastern Bloc. The term '' cold war'' is used because the ...
, "failsafe point" was the term used for the point of no return for American
Strategic Air Command Strategic Air Command (SAC) was both a United States Department of Defense Specified Command and a United States Air Force (USAF) Major Command responsible for command and control of the strategic bomber and intercontinental ballistic missile ...
nuclear bombers, just outside Soviet airspace. In the event of receiving an attack order, the bombers were required to linger at the failsafe point and wait for a second confirming order; until one was received, they would not arm their bombs or proceed further. The design was to prevent any single failure of the American command system causing nuclear war. This sense of the term entered the American popular lexicon with the publishing of the 1962 novel '' Fail-Safe''. (Other nuclear war command control systems have used the opposite scheme, fail-deadly, which requires continuous or regular proof that an enemy first-strike attack has ''not'' occurred to ''prevent'' the launching of a nuclear strike.)


See also

* Fail-fast * Control theory * Dead man's switch * EIA-485 * Elegant degradation *
Failing badly Failing badly and failing well are concepts in systems security and network security (and engineering in general) describing how a system reacts to failure. The terms have been popularized by Bruce Schneier, a cryptographer and security consultant ...
* Fail-deadly * Fault tolerance * IEC 61508 * Interlock *
Safe-life design In safe-life design, products are intended to be removed from service at a specific design life. Safe-life is particularly relevant to simple metal aircraft, where airframe components are subjected to alternating loads over the lifetime of the ai ...
* Safety engineering


References

{{DEFAULTSORT:Fail-Safe Safety Fault-tolerant computer systems