HOME

TheInfoList



OR:

Piston-driven air displacement pipettes are a type of
micropipette A pipette (sometimes spelled as pipett) is a laboratory tool commonly used in chemistry, biology and medicine to transport a measured volume of liquid, often as a media dispenser. Pipettes come in several designs for various purposes with diff ...
, which are tools to handle volumes of liquid in the microliter scale. They are more commonly used in biology and biochemistry, and less commonly in chemistry; the equipment is susceptible to damage from many organic solvents.


Operation

These pipettes operate by
piston A piston is a component of reciprocating engines, reciprocating pumps, gas compressors, hydraulic cylinders and pneumatic cylinders, among other similar mechanisms. It is the moving component that is contained by a cylinder and is made gas-tig ...
-driven
air The atmosphere of Earth is the layer of gases, known collectively as air, retained by Earth's gravity that surrounds the planet and forms its planetary atmosphere. The atmosphere of Earth protects life on Earth by creating pressure allowing for ...
displacement. A vacuum is generated by the vertical travel of a metallic or ceramic piston within an airtight sleeve. The upward movement of the piston, driven by the depression of the plunger, creates a vacuum in the space left vacant by the piston. To fill the vacuum, air from the tip rises, which is then replaced by the liquid that is drawn up into the tip and thus available for transport and dispensing elsewhere.
Sterile technique Asepsis is the state of being free from disease-causing micro-organisms (such as pathogenic bacteria, viruses, pathogenic fungi, and parasites). There are two categories of asepsis: medical and surgical. The modern day notion of asepsis is deriv ...
prevents liquid from coming into contact with the pipette itself. Instead, the liquid is drawn into and dispensed from a disposable pipette tip that is discarded after transferring fluid and a new pipette tip is used for the next transfer. Depressing the tip ejector button removes the tip, that is cast off without being handled by the operator and disposed of safely in an appropriate container. This also prevents contamination of or damage to the calibrated measurement mechanism by the substances being measured. The plunger is depressed to both draw up and dispense the liquid. Normal operation consists of depressing the plunger button to the first stop while the pipette is held in the air. The tip is then submerged in the liquid to be transported and the plunger is released in a slow and even manner. This draws the liquid up into the tip. The instrument is then moved to the desired dispensing location. The plunger is again depressed to the first stop, and then to the second stop, or 'blowout', position. This action will fully evacuate the tip and dispense the liquid. In an adjustable pipette, the volume of liquid contained in the tip is variable; it can be changed via a dial or other mechanism, depending on the model. Some pipettes include a small window which displays the currently selected volume. The plastic pipette tips are designed for aqueous solutions, and are not recommended for use with organic solvents that may dissolve the plastics of the tips or even the pipettes.


Main parts of a micropipette

# Plunger button # Tip ejector button # Volume adjustment dial # Digital volume indicator # Shaft # Attachment point for a disposable tip


Models

Several different type of air displacement pipettes exist: * adjustable or fixed * volume handled * Single-channel or multi-channel or repeater * adjustable tip spacing * conical tips or cylindrical tips * standard or locking * manual or electronic * manufacturer


Adjustable or fixed volume

Micropipettes can take a minimum volume of 0.2 µL and maximum volume of 10,000 µL (10 mL). They thus are used for smaller-scale transfers than equipment such as graduated pipettes, which come in 5, 10, 25 and 50 mL volumes. The most common type of pipettes can be set to a certain volume within its operational range and are called adjustable. These pipettes commonly have a label with their volume range like "10–100 µL". These limits are indeed the limits as overwinding these limits would result in damage of the pipetting system. The fixed volume pipette cannot be changed. As there are less moving parts, the mechanism is less complex, resulting in more accurate volume measurement. In 1972, several people of the
University of Wisconsin–Madison A university () is an institution of higher (or tertiary) education and research which awards academic degrees in several academic disciplines. Universities typically offer both undergraduate and postgraduate programs. In the United States, the ...
(mainly Warren Gilson and Henry Lardy) enhanced the fixed-volume pipette, developing the pipette with a variable volume. Warren Gilson founded Gilson Inc. based on this invention.


Volume

For optimal usage, every pipette supplier offers a broad range of different capacities. A small volume range of a pipette like 10–100 µL results in a much higher accuracy than a broad range from 0.1–1,000 µL per pipette. With regard to the volume transferred, the smallest pipette that can handle the required volume should be selected. This is important because accuracy decreases when the set volume is close to the pipette’s minimum capacity. For example, if 50 µl are dispensed using a 5,000 µl pipette, the results will be rather poor. Using a 300 µl pipette will give better results, whereas using a 50 µl pipette would be ideal.


Tips

For the pipetting process there are two components necessary: The pipette and
disposable A disposable (also called disposable product) is a product designed for a single use after which it is recycled or is disposed as solid waste. The term is also sometimes used for products that may last several months (e.g. disposable air filter ...
tips. The tips are
plastic Plastics are a wide range of synthetic or semi-synthetic materials that use polymers as a main ingredient. Their plasticity makes it possible for plastics to be moulded, extruded or pressed into solid objects of various shapes. This adaptabi ...
-made tools for single-use. In general, they are made of Polypropylene. Depending on the size of the pipette, the user needs specific tip sizes like: 10 µL, 100 µL, 200 µL, 1,000 µL, other non-standard sizes, such as 5,000 µL (5 mL) or 10,000 µL (10 mL). The majority of tips have a color code for easy spotting like natural (colorless) for low volumes (0.1–10 µL), yellow (10–100 µL), or blue (100–1,000 µL). The corresponding pipette has the same
color code A color code is a system for displaying information by using different colors. The earliest examples of color codes in use are for long-distance communication by use of flags, as in semaphore communication. The United Kingdom adopted a color c ...
, printed on the pipette. For special applications, there are filter-tips available. These tips have a little piece of
foam Foams are materials formed by trapping pockets of gas in a liquid or solid. A bath sponge and the head on a glass of beer are examples of foams. In most foams, the volume of gas is large, with thin films of liquid or solid separating the r ...
plastic in the upper conus to prevent sample
aerosols An aerosol is a suspension of fine solid particles or liquid droplets in air or another gas. Aerosols can be natural or anthropogenic. Examples of natural aerosols are fog or mist, dust, forest exudates, and geyser steam. Examples of anthropogen ...
contaminating the pipette. In general, all tips are stored in 8 × 12 boxes for 96 pieces in an upright position. The spacing of tips in these boxes is usually standardised for multichannel pipette compatibility from a number of different suppliers. Two major tip systems exist, called ''conical'' or ''cylindrical'', depending on the shape of the contact point of the pipettes and the tip.


Single-channel and multi-channel pipettes

Depending on the number of pistons in a pipette, there is a differentiation between single-channel pipettes and multi-channel pipettes. For manual high-throughput applications like filling up a 96-well
microtiter plate A microplate, also known as a microtiter plate (''Microtiter'' is a registered trademark in the United States, therefore it should not be used generically without attribution), microwell plate or multiwell, is a flat plate with multiple "wells" ...
most researchers prefer a multi-channel pipette. Instead of handling well by well, a row of 8 wells can be handled in parallel as this type of pipette has 8 pistons in parallel.


Adjustable tip spacing pipettes

Some manufacturers offer adjustable tip spacing pipettes. These allow to transfer multiple samples in parallel between different labware formats.


Electronic pipettes

To improve the ergonomics of pipettes by reducing the necessary force, electronic pipettes were developed. The manual movement of the piston is replaced by a small
electric motor An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and electric current in a wire winding to generate force ...
powered by a battery. Whereas manual pipettes need a movement of the thumb (up to 3 cm), electronic pipettes have a main button. The programming of the pipette is generally done by a control
wheel A wheel is a circular component that is intended to rotate on an axle bearing. The wheel is one of the key components of the wheel and axle which is one of the six simple machines. Wheels, in conjunction with axles, allow heavy objects to be ...
and some further buttons. All settings are displayed on a small display. Electronic pipettes can decrease the risk of RSI-type injuries.


Repeaters

Repeaters are specialized pipettes, optimized for repeated working steps like dispensing several times a specific volume like 20 µL from a single aspiration of a larger volume. In general, they have specific tips which do not fit on normal pipettes. Some electronic pipettes are able to perform this function using standard tips.


Locking mechanism

Some air displacement pipettes can additionally feature a locking mechanism (referred to as "locking pipettes") to allow better changing of volume yet preserving accuracy. By locking the set volume while performing several identical pipetting actions, accidental changes to the pipette volume setting are avoided. The lock mechanism is typically a mechanical toggle close to the pipette setting controls that interferes with the setting mechanism to prevent movement. Some pipettes, however, feature dials for setting the individual volume digits that can only be adjusted when unlocked by depressing and twisting the plunger.


Calibration

For sustained accuracy and consistent and repeatable operation, pipettes should be
calibrated In measurement technology and metrology, calibration is the comparison of measurement values delivered by a device under test with those of a calibration standard of known accuracy. Such a standard could be another measurement device of known a ...
at periodic intervals. These intervals vary depending on several factors: *The skill and training of the operators. Skilled operators tend to operate the instrument more correctly and make fewer accuracy-robbing mistakes. *The liquid dispensed by the pipette.
Corrosive A corrosive substance is one that will damage or destroy other substances with which it comes into contact by means of a chemical reaction. Etymology The word ''corrosive'' is derived from the Latin verb ''corrodere'', which means ''to gnaw'', ...
and volatile liquids tend to emit vapors which ascend into the pipette shaft even under proper operating conditions and may corrode the metal piston and springs, or the seals and o-rings that provide an air-tight seal between the piston and the surrounding sleeve. *Proper and careful handling. Pipettes that are frequently dropped, are subjected to careless handling or horseplay, or that are not properly stored in a vertical position, will tend to degrade in accuracy over time. *The accuracy required by the instrument. Applications requiring maximum accuracy also demand more frequent calibration. Instruments used for purely research applications or in educational settings generally require less frequent calibration. Under average conditions, most pipettes can be calibrated semi-annually (every six months) and provide satisfactory performance. Institutions that are regulated by the
Food and Drug Administration The United States Food and Drug Administration (FDA or US FDA) is a federal agency of the Department of Health and Human Services. The FDA is responsible for protecting and promoting public health through the control and supervision of food s ...
's GMP/GLP regulations generally benefit from quarterly calibration, or every three months. Critical applications may require monthly service, while research and educational institutions may need only annual service. These are general guidelines and any decision on the appropriate calibration interval should be made carefully and include considerations of the pipette in question (some are more reliable than others), the conditions under which the pipette is used, and the operators who use it. Calibration is generally accomplished through means of gravimetric analysis. This entails dispensing samples of distilled water into a receiving vessel perched atop a precision analytical balance. The density of water is a well-known constant, and thus the mass of the dispensed sample provides an accurate indication of the volume dispensed. Relative humidity, ambient temperature, and barometric pressure are factors in the accuracy of the measurement, and are usually combined in a complex formula and computed as the Z-factor. This Z-factor is then used to modify the raw mass data output of the balance and provide an adjusted and more accurate measurement. The colorimetric method uses precise concentrations of colored water to affect the measurement and determine the volume dispensed. A spectrophotometer is used to measure the color difference before and after aspiration of the sample, providing a very accurate reading. This method is more expensive than the more common gravimetric method, given the cost of the colored reagents, and is recommended when optimal accuracy is required. It is also recommended for extremely low-volume pipette calibration, in the 2 microliter range, because the inherent uncertainties of the gravimetric method, performed with standard laboratory balances, becomes excessive. Properly calibrated microbalances, capable of reading in the range of micrograms (10−6 g) can also be used effectively for gravimetric analysis of low-volume micropipettes, but only if environmental conditions are under strict control. Six-place balances and environmental controls dramatically increase the cost of such calibrations.


Additional images

File:Single channel rack.jpg, Oxford Single-Channel Pipettes File:Different volumes of micropipettes.jpg, Different volumes of micropipettes.


References

{{DEFAULTSORT:Air Displacement Pipette Laboratory glassware Laboratory equipment Microbiology equipment Molecular biology laboratory equipment Volumetric instruments