Changes
Changes compared to the Medical Device Directive include changes in device classification and device scope, stricter oversight of manufacturers by Notified Bodies, introduction of the "Person Responsible for Regulatory Compliance" (PRRC) and of the economic operator concept, the requirement of Unique Device Identification marking for devices, EUDAMED registration (see below), UDI requirements, and increased post-market surveillance activities.Scope and classification
The scope of the MDR has been expanded to cover a range of products without an intended medical purpose. This category includes some contact lenses, tattoo removal lasers, equipment for liposuction, and others. Annex XVI of the MDR lists all the respective categories. Additionally, the classification rules of Annex VIII of the MDR have been expanded compared to the MDD to now 22 rules. Reusable surgical instruments are now been included in their own category, often called "I R". As per § 120(3) of the regulation, aspects relating to their re-usability are under the scope of Notified Body review starting 26 May 2024. Other classification changes relate toEconomic operator roles
The MDR in §2 (35) now defines several different roles for economic operators in relation to medical devices. The obligations of economic operators are detailed in the following sections: * §10 - Manufacturer * §11 - Authorised Representative * §13 - Importer * §14 - Distributor Manufacturers, Authorised Representatives and importers have to register in the EUDAMED database to receive a Single Registration Number (SRN); only distributors of medical devices do not have to register.Person responsible for regulatory compliance
The MDR in § 15 introduces the role of the "Person Responsible for Regulatory Compliance" (PRRC), that manufacturers and Authorized Representatives will have to have available within their organisation. The PRRC is assigned several duties and responsibilities, including making sure post-market surveillance obligations are fulfilled. Persons taking on the role and responsibilities of a PRRC have to meet certain qualitifcations with regard to education and experience. Further details on the PRRC are given in the EU guidance MDCG 2019-7.General safety and performance requirements
The "General Safety and Performance Requirements" (GSPR) of the MDR replace the "Essential Requirements" (ER) of the MDD. Annex I of the MDR lists 23 requirements, divided in three chapters: * General requirements (1-9) * Requirements regarding design and manufacture (10-22) * Requirements regarding the information supplied with the device (23) Compared to the MDD ER, the MDR GSPR have been expanded, e.g. with regards to devices for lay use, IT security, and devices without a medical purpose. Manufacturers are expected to utilize harmonized standards and common requirements to demonstrate conformance to the GSPR.European database on medical devices
The European database on medical devices (EUDAMED) is a database to collect and make available information of medical devices and in-vitro-diagnostica. EUDAMED has six modules: * Actors registration * UDI/Devices registration * Notified Bodies and Certificates * Clinical Investigations and performance studies * Vigilance and post-market surveillance * Market Surveillance Data on economic operators, devices registration and certificates are available to the public. The database will allow to link manufacturer's certification and "Single Registration Number" (SRN) as well as the Basic UDI. The so-called "Summary of Safety and Clinical Performance" (SSCP), required for some high-risk medical devices, will also be accessible to the public through the database. More details on the operation of EUDAMED are given in Commission Implementing Regulation (EU) 2021/2078. A similar database is the Global Unique Device Identification Database (GUDID) of the FDA.Medical Device Coordination Group
In accordance with §103 of the MDR, the Medical Device Coordination Group (MDCG) has been established. The MDCG and its sub-groups publish guidances that provide clarification and support to national competent authorities, notified bodies and economic operators on the details of the implementation of the MDR and IVDR. The members of the MDCG are experts appointed by the EU member states.Implementation date
The date by which the Regulation was to be fully implemented by replacing the previous directives was originally defined as 26 May 2020. Following the international health emergencySee also
*References
{{reflistExternal links