HOME

TheInfoList



OR:

E and M signaling is a type of supervisory line
signaling In signal processing, a signal is a function that conveys information about a phenomenon. Any quantity that can vary over space or time can be used as a signal to share messages between observers. The ''IEEE Transactions on Signal Processing'' ...
that uses DC signals on separate leads, called the "E" lead and "M" lead, traditionally used in the telecommunications industry between
telephone switches telephone exchange, telephone switch, or central office is a telecommunications system used in the public switched telephone network (PSTN) or in large enterprises. It interconnects telephone subscriber lines or virtual circuits of digital syst ...
. Various mnemonic names have been used to memorize these letters, such as ''Ear'' and ''Mouth'', the most common variation. E&M was originally developed for signaling between
PABX A business telephone system is a multiline telephone system typically used in business environments, encompassing systems ranging in technology from the key telephone system (KTS) to the private branch exchange (PBX). A business telephone syst ...
s in different geographic locations over an analog private circuit. The protocol was later extended for use on digital carrier system with
Channel Associated Signaling Channel-associated signaling (CAS), also known as ''per-trunk signaling'' (PTS), is a form of digital communication signaling. As with most telecommunication signaling methods, it uses routing information to direct the payload of voice or data to i ...
(CAS).


Signaling units and trunk circuits

The E&M standards were initially developed by
Bell Labs Nokia Bell Labs, originally named Bell Telephone Laboratories (1925–1984), then AT&T Bell Laboratories (1984–1996) and Bell Labs Innovations (1996–2007), is an American industrial research and scientific development company owned by mult ...
and extended by national PTT administrations. The standard defines two sides of the interface, the trunk circuit and the signaling unit. The trunk circuit is normally the side to which the PABX is connected. The signaling unit is the special modem that converts the DC signaling protocol into tones that could be transmitted over a four-wire link back to the PTT exchange. The signaling unit and trunk circuit communicate their status over the E and M leads, using a combination of battery and earth (also known as ground) levels. The battery signal level used in the standard is nominally −48 VDC. All E&M installations require that the positive terminal of the battery is connected to a reliable shared earth circuit. The maximum distance between the signaling unit and the trunk interface is determined by the resistance of the wire, but is normally less than 100 meters for adequate noise immunity.


Variants

The group of E&M signaling includes several variations. ''Type I'' is the most common standard in North America and Japan, and signals an outgoing call from the PBX to the signaling unit with Battery on the M ("Mouth") lead. Incoming calls from the CO are signaled by an earth (ground) signal on the E ("Ear") lead. The interface is vulnerable to poor earthing at either end, and interference from external electrical noise which act on inferior voice signal quality. ''Types II to IV'' are variants which attempt to overcome the main limitation of Type I, which is the reference to earth at each end of the circuit. Types II-IV use the Signal Battery (SB) and Signal Ground (SG) lead in conjunction with the E&M wires. This improves noise immunity as the Signal Ground does not carry the same heavy currents as normal ground connections and provides a low resistance return path for signaling. However, if the main ground connection fails all earth current may flow via the interface, causing signaling failure, hum and in extreme cases destruction of equipment. ''Type V'' is the most common variant in use outside United States. In contrast to Type I, both ends of the connection indicate a call by grounding the relevant lead. This means that it is easy to interconnect two PABXs "back-to-back" by crossing over the E&M leads and transmit and receive pairs. ''SSDC5'' is commonly used in the United Kingdom and unlike Type V the on- and off-hook state, are backwards to allow for fail-safe operation. If the line breaks, the interface defaults to busy.


Number of wires

E&M defines eight wires: * E: It is often called ''ear'' * M: It is often called ''mouth'' or ''magneto'' * SG and SB: signal ground and signal battery * T and R: Tip and Ring – the ground and battery of the receiver voice pair * T1 and R1: the ground and battery of the transmitter voice pair ''4-wire E&M'' uses a 4-wire (2-pair) transmission path for the voice signal. ''2-wire E&M'' uses a single pair for both transmit and receive voice signal. This is much inferior to 4-wire E&M as the 2-wire interface uses hybrid transformers which reduce signal quality and can introduce echo.


Address signaling

The mechanisms described so far only allow circuit seizure –
on-hook In telephony, on-hook and off-hook are two states of a communication circuit. On subscriber telephones the states are produced by placing the handset onto or off the hookswitch. Placing the circuit into the off-hook state is also called ''seizing th ...
and
off-hook In telephony, on-hook and off-hook are two states of a communication circuit. On subscriber telephones the states are produced by placing the handset onto or off the hookswitch. Placing the circuit into the off-hook state is also called ''seizing th ...
– to be signaled. In order to allow dialing over the interface, "start" signaling mechanisms are defined. This allows the other end to know when to send the dialed digits, which are transmitted by pulse ( loop disconnect) or
multi-frequency In telephony, multi-frequency signaling (MF) is a type of signaling that was introduced by the Bell System after World War II. It uses a combination of audible tones for address (telephone number) transport and supervision signaling on trunk lines b ...
tones. E&M defines three methods of "start" signaling: * Wink Start – when the originator goes off hook, the other end transmits a short (140-290ms) off-hook signal and returns to on-hook. The originator detects the wink and then sends the dialed digits. The other end goes permanently off-hook (seized) when the call is answered. * Delay Start – the originator goes off hook, waits a pre-defined delay, and then checks for on-hook from the other end before sending the digits. * Immediate Start – The originator goes off hook, waits 150ms and then sends the dialed digits.


Origin of "E&M"

The choice of letters for the E and M leads was fortuitous, unrelated to any names or meanings.Bell Telephone Laboratories, G.E. Schindler (ed.), ''A History of Engineering and Science in the Bell System—Switching Technology (1925-1975)'', 1982, p.52 However, various names have been associated with the letters ''E'' and ''M'': *''E'' for ''ear'', i.e., when the near-end ''E'' lead was grounded, the far end was calling and ''wanted your ear.'' Whereas ''M'' is commonly called ''mouth'', because when the near-end wanted to call (i.e., speak to) the far end, −48 vdc was applied to that lead. *''E'' for ''earth'' and ''
magneto A magneto is an electrical generator that uses permanent magnets to produce periodic pulses of alternating current. Unlike a dynamo, a magneto does not contain a commutator to produce direct current. It is categorized as a form of alternator, ...
'' for ''M'', from the very earliest days of telephony. An actual magneto was used to apply −48 volts to the M lead through mechanical relay switches, while the E lead is normally held to ground (earth) unless acknowledging the signaling from the M lead. *In another
story Story or stories may refer to: Common uses * Story, a narrative (an account of imaginary or real people and events) ** Short story, a piece of prose fiction that typically can be read in one sitting * Story (American English), or storey (British ...
, the proposed labels were R and T for reception and transmission of signaling. However R and T were already used as labels for the tip and ring wire pair carrying voice signals. Thus a letter within each of the word ''recEive'' and ''transMit'' was chosen. *Yet another explanation is that these were sequential designations on the wiring list of the original design.


See also

*
Pulse link repeater In telecommunications, a pulse link repeater (PLR) is a device that interfaces concatenated E and M signaling E and M signaling is a type of supervisory line signaling that uses DC signals on separate leads, called the "E" lead and "M" lead, tradit ...
*
Signaling (telecommunications) In telecommunication, signaling is the use of signals for controlling communications. This may constitute an information exchange concerning the establishment and control of a telecommunication circuit and the management of the network. Classif ...


References

{{DEFAULTSORT:E And M Signaling Telephony signals