Coolidge Tube
   HOME

TheInfoList



OR:

An X-ray tube is a vacuum tube that converts electrical input power into X-rays. The availability of this controllable source of X-rays created the field of radiography, the imaging of partly opaque objects with penetrating
radiation In physics, radiation is the emission or transmission of energy in the form of waves or particles through space or through a material medium. This includes: * ''electromagnetic radiation'', such as radio waves, microwaves, infrared, visi ...
. In contrast to other sources of
ionizing radiation Ionizing radiation (or ionising radiation), including nuclear radiation, consists of subatomic particles or electromagnetic waves that have sufficient energy to ionize atoms or molecules by detaching electrons from them. Some particles can travel ...
, X-rays are only produced as long as the X-ray tube is energized. X-ray tubes are also used in
CT scan A computed tomography scan (CT scan; formerly called computed axial tomography scan or CAT scan) is a medical imaging technique used to obtain detailed internal images of the body. The personnel that perform CT scans are called radiographers ...
ners, airport luggage scanners, X-ray crystallography, material and structure analysis, and for industrial inspection. Increasing demand for high-performance
Computed tomography A computed tomography scan (CT scan; formerly called computed axial tomography scan or CAT scan) is a medical imaging technique used to obtain detailed internal images of the body. The personnel that perform CT scans are called radiographers ...
(CT) scanning and angiography systems has driven development of very high performance medical X-ray tubes.


History

X-ray tubes evolved from experimental Crookes tubes with which X-rays were first discovered on November 8, 1895, by the German physicist Wilhelm Conrad Röntgen. The first-generation '' cold cathode'' or ''Crookes'' X-ray tubes were used until the 1920s. These tubes work by ionisation of residual gas within the tube. The positive ions bombard the cathode of the tube to release electrons, which are accelerated toward the anode and produce X-rays when they strike it. The Crookes tube was improved by William Coolidge in 1913. The ''Coolidge'' tube, also called a ''hot cathode'' tube, uses thermionic emission, where a tungsten cathode is heated to a sufficiently high temperature to emit electrons, which are then accelerated toward the anode in a near perfect vacuum. Until the late 1980s, X-ray generators were merely high-voltage, AC to DC variable power supplies. In the late 1980s a different method of control was emerging, called high speed switching. This followed the electronics technology of switching power supplies (aka
switch mode power supply A switched-mode power supply (switching-mode power supply, switch-mode power supply, switched power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like ...
), and allowed for more accurate control of the X-ray unit, higher quality results and reduced X-ray exposures.


Physics

As with any vacuum tube, there is a cathode, which emits electrons into the vacuum and an anode to collect the electrons, thus establishing a flow of electrical current, known as the
beam Beam may refer to: Streams of particles or energy *Light beam, or beam of light, a directional projection of light energy **Laser beam *Particle beam, a stream of charged or neutral particles **Charged particle beam, a spatially localized grou ...
, through the tube. A high voltage power source, for example 30 to 150
kilovolt The volt (symbol: V) is the unit of electric potential, electric potential difference (voltage), and electromotive force in the International System of Units (SI). It is named after the Italian physicist Alessandro Volta (1745–1827). Defini ...
s (kV), called the ''tube voltage'', is connected across cathode and anode to accelerate the electrons. The X-ray spectrum depends on the anode material and the accelerating voltage. Electrons from the cathode collide with the anode material, usually tungsten,
molybdenum Molybdenum is a chemical element with the symbol Mo and atomic number 42 which is located in period 5 and group 6. The name is from Neo-Latin ''molybdaenum'', which is based on Ancient Greek ', meaning lead, since its ores were confused with lea ...
or copper, and accelerate other electrons, ions and nuclei within the anode material. About 1% of the energy generated is emitted/radiated, usually perpendicular to the path of the electron beam, as X-rays. The rest of the energy is released as heat. Over time, tungsten will be deposited from the target onto the interior surface of the tube, including the glass surface. This will slowly darken the tube and was thought to degrade the quality of the X-ray beam. Vaporized tungsten condenses on the inside of the envelope over the "window" and thus acts as an additional filter and decreases the tube's ability to radiate heat. Eventually, the tungsten deposit may become sufficiently conductive that at high enough voltages, arcing occurs. The arc will jump from the cathode to the tungsten deposit, and then to the anode. This arcing causes an effect called " crazing" on the interior glass of the X-ray window. With time, the tube becomes unstable even at lower voltages, and must be replaced. At this point, the tube assembly (also called the "tube head") is removed from the X-ray system, and replaced with a new tube assembly. The old tube assembly is shipped to a company that reloads it with a new X-ray tube. The two X-ray photon-generating effects are generally called the 'Characteristic effect' and the bremsstrahlung effect, a compound of the German ''bremsen'' meaning to brake, and ''Strahlung'' meaning
radiation In physics, radiation is the emission or transmission of energy in the form of waves or particles through space or through a material medium. This includes: * ''electromagnetic radiation'', such as radio waves, microwaves, infrared, visi ...
. The range of photonic energies emitted by the system can be adjusted by changing the applied voltage, and installing aluminum filters of varying thicknesses. Aluminum filters are installed in the path of the X-ray beam to remove "soft" (non-penetrating) radiation. The number of emitted X-ray photons, or dose, are adjusted by controlling the current flow and exposure time.


Heat released

Heat is produced in the focal spot of the anode. Since a small fraction (less than or equal to 1%) of electron energy is converted to X-rays, it can be ignored in heat calculations. The quantity of heat produced (in Joule) in the focal spot is given by : :E_\mathrm = w \mathrm \mathrm \mathrm :w being the waveform factor :\mathrm= peak AC voltage (in Volts) :\mathrm = tube current (in mili Amperes) :\mathrm = exposure time (in seconds) Heat Unit (HU) was used in the past as an alternative to Joule. It is a convenient unit when a single-phase power source is connected to the X-ray tube. With a full-wave rectification of a
sine wave A sine wave, sinusoidal wave, or just sinusoid is a curve, mathematical curve defined in terms of the ''sine'' trigonometric function, of which it is the graph of a function, graph. It is a type of continuous wave and also a Smoothness, smooth p ...
, w=\frac \approx 0.707, thus the heat unit: :1 HU = 0.707 J :1.4 HU = 1 J


Types


Crookes tube (cold cathode tube)

Crookes tubes generated the electrons needed to create X-rays by ionization of the residual air in the tube, instead of a heated
filament The word filament, which is descended from Latin ''filum'' meaning " thread", is used in English for a variety of thread-like structures, including: Astronomy * Galaxy filament, the largest known cosmic structures in the universe * Solar filament ...
, so they were partially but not completely evacuated. They consisted of a glass bulb with around 10−6 to 5×10−8 atmospheric pressure of air (0.1 to 0.005 Pa). They had an aluminum cathode plate at one end of the tube, and a platinum anode target at the other end. The anode surface was angled so that the X-rays would radiate through the side of the tube. The cathode was concave so that the electrons were focused on a small (~1 mm) spot on the anode, approximating a point source of X-rays, which resulted in sharper images. The tube had a third electrode, an anticathode connected to the anode. It improved the X-ray output, but the method by which it achieved this is not understood. A more common arrangement used a copper plate anticathode (similar in construction to the cathode) in line with the anode such that the anode was between the cathode and the anticathode. To operate, a DC voltage of a few
kilovolt The volt (symbol: V) is the unit of electric potential, electric potential difference (voltage), and electromotive force in the International System of Units (SI). It is named after the Italian physicist Alessandro Volta (1745–1827). Defini ...
s to as much as 100 kV was applied between the anodes and the cathode, usually generated by an
induction coil An induction coil or "spark coil" (archaically known as an inductorium or Ruhmkorff coil after Heinrich Rühmkorff) is a type of electrical transformer used to produce high-voltage pulses from a low-voltage direct current (DC) supply. p.98 To ...
, or for larger tubes, an electrostatic machine. Crookes tubes were unreliable. As time passed, the residual air would be absorbed by the walls of the tube, reducing the pressure. This increased the voltage across the tube, generating 'harder' X-rays, until eventually the tube stopped working. To prevent this, 'softener' devices were used (see picture). A small tube attached to the side of the main tube contained a mica sleeve or chemical that released a small amount of gas when heated, restoring the correct pressure. The glass envelope of the tube would blacken with usage due to the X-rays affecting its structure.


Coolidge tube (hot cathode tube)

In the Coolidge tube, the electrons are produced by thermionic effect from a tungsten
filament The word filament, which is descended from Latin ''filum'' meaning " thread", is used in English for a variety of thread-like structures, including: Astronomy * Galaxy filament, the largest known cosmic structures in the universe * Solar filament ...
heated by an electric current. The filament is the cathode of the tube. The high voltage potential is between the cathode and the anode, the electrons are thus accelerated, then hit the anode. There are two designs: end-window tubes and side-window tubes. End window tubes usually have "transmission target" which is thin enough to allow X-rays to pass through the target (X-rays are emitted in the same direction as the electrons are moving.) In one common type of end-window tube, the filament is around the anode ("annular" or ring-shaped), the electrons have a curved path (half of a toroid). What is special about side-window tubes is an electrostatic lens is used to focus the beam onto a very small spot on the anode. The anode is specially designed to dissipate the heat and wear resulting from this intense focused barrage of electrons. The anode is precisely angled at 1-20 degrees off perpendicular to the electron current to allow the escape of some of the X-ray photons which are emitted perpendicular to the direction of the electron current. The anode is usually made of tungsten or molybdenum. The tube has a window designed for escape of the generated X-ray photons. The power of a Coolidge tube usually ranges from 0.1 to 18 kW.


Rotating anode tube

A considerable amount of heat is generated in the focal spot (the area where the beam of electrons coming from the cathode strike to) of a stationary anode. Rather, a rotating anode lets the electron beam sweep a larger area of the anode, thus redeeming the advantage of a higher intensity of emitted radiation, along with reduced damage to the anode compared to its stationary state. The focal spot temperature can reach during an exposure, and the anode assembly can reach following a series of large exposures. Typical anodes are a tungsten-rhenium target on a molybdenum core, backed with graphite. The rhenium makes the tungsten more ductile and resistant to wear from the impact of the electron beams. The
molybdenum Molybdenum is a chemical element with the symbol Mo and atomic number 42 which is located in period 5 and group 6. The name is from Neo-Latin ''molybdaenum'', which is based on Ancient Greek ', meaning lead, since its ores were confused with lea ...
conducts heat from the target. The graphite provides thermal storage for the anode, and minimizes the rotating mass of the anode.


Microfocus X-ray tube

Some X-ray examinations (such as, e.g.,
non-destructive testing Nondestructive testing (NDT) is any of a wide group of analysis techniques used in science and technology industry to evaluate the properties of a material, component or system without causing damage. The terms nondestructive examination (NDE), n ...
and 3-D microtomography) need very high-resolution images and therefore require X-ray tubes that can generate very small focal spot sizes, typically below 50 μm in diameter. These tubes are called microfocus X-ray tubes. There are two basic types of microfocus X-ray tubes: solid-anode tubes and metal-jet-anode tubes. Solid-anode microfocus X-ray tubes are in principle very similar to the Coolidge tube, but with the important distinction that care has been taken to be able to focus the electron beam into a very small spot on the anode. Many microfocus X-ray sources operate with focus spots in the range 5-20 μm, but in the extreme cases spots smaller than 1 μm may be produced. The major drawback of solid-anode microfocus X-ray tubes is their very low operating power. To avoid melting the anode, the electron-beam power density must be below a maximum value. This value is somewhere in the range 0.4-0.8 W/μm depending on the anode material. This means that a solid-anode microfocus source with a 10 μm electron-beam focus can operate at a power in the range 4-8 W. In metal-jet-anode microfocus X-ray tubes the solid metal anode is replaced with a jet of liquid metal, which acts as the electron-beam target. The advantage of the metal-jet anode is that the maximum electron-beam power density is significantly increased. Values in the range 3-6 W/μm have been reported for different anode materials (gallium and tin). In the case with a 10 μm electron-beam focus a metal-jet-anode microfocus X-ray source may operate at 30-60 W. The major benefit of the increased power density level for the metal-jet X-ray tube is the possibility to operate with a smaller focal spot, say 5 μm, to increase image resolution and at the same time acquire the image faster, since the power is higher (15-30 W) than for solid-anode tubes with 10 μm focal spots.


Hazards of X-ray production from vacuum tubes

Any vacuum tube operating at several thousand volts or more can produce X-rays as an unwanted byproduct, raising safety issues. The higher the voltage, the more penetrating the resulting radiation and the more the hazard.
CRT CRT or Crt may refer to: Science, technology, and mathematics Medicine and biology * Calreticulin, a protein *Capillary refill time, for blood to refill capillaries *Cardiac resynchronization therapy and CRT defibrillator (CRT-D) * Catheter-re ...
displays, once common in color televisions and computer displays, operate at depending on size, making them the main concern among household appliances. Historically, concern has focused less on the
cathode ray tube A cathode-ray tube (CRT) is a vacuum tube containing one or more electron guns, which emit electron beams that are manipulated to display images on a phosphorescent screen. The images may represent electrical waveforms ( oscilloscope), pictu ...
, since its thick glass envelope is impregnated with several pounds of lead for shielding, than on high voltage (HV)
rectifier A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The reverse operation (converting DC to AC) is performed by an Power ...
and voltage regulator tubes inside earlier TVs. In the late 1960s it was found that a failure in the HV supply circuit of some General Electric TVs could leave excessive voltages on the regulator tube, causing it to emit X-rays. The models were recalled and the ensuing scandal caused the US agency responsible for regulating this hazard, the
Center for Devices and Radiological Health The Center for Devices and Radiological Health (CDRH) is the branch of the United States Food and Drug Administration (FDA) responsible for the premarket approval of all medical devices, as well as overseeing the manufacturing, performance and safe ...
of the Food and Drug Administration (FDA), to require that all TVs include circuits to prevent excessive voltages in the event of failure. The hazard associated with excessive voltages was eliminated with the advent of all-
solid-state Solid state, or solid matter, is one of the four fundamental states of matter. Solid state may also refer to: Electronics * Solid-state electronics, circuits built of solid materials * Solid state ionics, study of ionic conductors and their use ...
TVs, which have no tubes other than the CRT. Since 1969, the FDA has limited TV X-ray emission to 0.5 mR (
milliroentgen The roentgen or röntgen (; symbol R) is a legacy unit of measurement for the radiation exposure, exposure of X-rays and gamma rays, and is defined as the electric charge freed by such radiation in a specified volume of air divided by the mass of ...
) per hour. As other screen technologies advanced, starting in the 1990s, the production of CRTs was slowly phased out. These other technologies, such as
LED A light-emitting diode (LED) is a semiconductor Electronics, device that Light#Light sources, emits light when Electric current, current flows through it. Electrons in the semiconductor recombine with electron holes, releasing energy i ...
,
LCD A liquid-crystal display (LCD) is a flat-panel display or other electronically modulated optical device that uses the light-modulating properties of liquid crystals combined with polarizers. Liquid crystals do not emit light directly but in ...
and OLED, are incapable of producing x-rays due to the lack of a high voltage transformer.


See also

*
Electron beam tomography Electron beam computed tomography (EBCT) is a specific form of computed tomography (CT) in which the X-ray tube is not mechanically spun in order to rotate the source of X-ray photons. This different design was explicitly developed to better im ...
*
Coronary angiography Coronary () may, as shorthand in English, be used to mean: * Coronary circulation, the system of arteries and veins in mammals ** Coronary artery disease ** Coronary occlusion ** A myocardial infarction, a heart attack As adjective * Referring to ...
*
Synchrotron radiation Synchrotron radiation (also known as magnetobremsstrahlung radiation) is the electromagnetic radiation emitted when relativistic charged particles are subject to an acceleration perpendicular to their velocity (). It is produced artificially in ...
* X-ray fluorescence * X-ray generator * glass-to-metal-seal


Patents

* Coolidge, , "''X-ray tube''" * Langmuir, , "''Method of and apparatus for controlling X-ray tubes'' *Coolidge, , "''X-ray tube''" *Coolidge, , "''X-ray tube''"


References


External links


X-ray Tube
- A Radiograph of an X-ray Tube
NY State Society of Radiologic SciencesCollection of X-ray tubes
by Grzegorz Jezierski of Poland
Excillum AB, a manufacturer of metal-jet-anode microfocus x-ray tubes
of how X-ray tubes work. {{Authority control English inventions Radiology
Tube Tube or tubes may refer to: * ''Tube'' (2003 film), a 2003 Korean film * ''The Tube'' (TV series), a music related TV series by Channel 4 in the United Kingdom * "Tubes" (Peter Dale), performer on the Soccer AM television show * Tube (band), a ...
Particle accelerators