Chemical Cartridge
   HOME

TheInfoList



OR:

A respirator cartridge or canister is a type of filter that removes gases, volatile organic compounds (VOCs), and other vapors from air through adsorption, absorption (chemistry), absorption, or chemisorption. It is one of two basic types of filters used by air-purifying respirators. The other is a Mechanical filter respirator, mechanical filter, which removes only particulates. Hybrid filters combine the two. Workplace air that is polluted with fine particulate matter or noxious gases but that contains enough oxygen (in the US, this is ruled to be a concentration above 19.5%; in the Russian Federation, above 18%), can be rendered safe via air-purifying respirators. Cartridges are of different types, and must be chosen correctly and replaced on an appropriate schedule.


Purification methods


Absorption

Capturing noxious gases may be accomplished by sorbents. These materials (activated carbon, , zeolite, etc.) have a large specific surface area and can Absorption (chemistry), absorb many gases. Typically, such sorbents are in the form of Granular material, granules, and fill the cartridge. Contaminated air travels through the cartridge's bed of sorbent granules. Movable harmful gas molecules collide with the surface of the sorbent and remain therein. The sorbent gradually saturates and loses its ability to capture pollutants. The bond strength between captured molecules and the sorbent is small, and molecules can separate from the sorbent and return to the air. The sorbent's ability to capture gases depends on the properties of the gases and their concentrations, including air temperature and relative humidity.Conference listing
/ref>


Chemisorption

Chemisorption utilizes a chemical reaction between the gas and the absorber. The ability of some harmful gases to react chemically with other substances can be used to capture them. Creating strong links between gas molecules and a sorbent may allow repeated use of a canister if it has enough unsaturated sorbent. Copper salts, for example, can form complex compounds with ammonia. A mixture of copper ions (+2), Smithsonite, zinc carbonate, and TEDA can detoxify hydrogen cyanide. By saturating activated carbon with chemicals, chemisorption can be used to help the material make stronger ties with molecules of trapped gases and improve the capture of harmful gases. Saturation of iodine improves Mercury (element), mercury capture, saturation of metal Salt (chemistry), salts improves ammonia capture, and saturation of metal oxides improves acid gas capture.


Catalytic decomposition

Some harmful gases can be neutralized through catalytic oxidation. A hopcalite can oxidize toxic carbon monoxide (CO) into harmless carbon dioxide (CO2). The effectiveness of this catalyst strongly decreases as relative humidity increases. Therefore, desiccants are often added. Air always contains water vapor, and after saturation of the desiccant, the catalyst ceases to function.


Combined cartridges

Combined, or multi-gas cartridges protect from harmful gases by using multiple sorbents or catalysts. An example is ''ASZM-TEDA Carbon'' used in CBRN defense, CBRN masks by the US Army. This is a form of activated carbon saturated with copper, zinc, silver, and molybdenum compounds, as well as with triethylenediamine (TEDA).


Classification and marking

Cartridge selection comes after assessing the atmosphere. National Institute for Occupational Safety and Health, NIOSH guides cartridge choice in the US along with manufacturer recommendations.


United States

In the US, approval for respirator cartridge NIOSH air filtration rating, particulate filtration efficiency classification and certification is administered by the National Institute for Occupational Safety and Health (NIOSH) as part of Part 84 of Title 42 of the Code of Federal Regulations (42 CFR 84). Manufacturers can certify cartridges intended for purifying workplace air from various gaseous contaminants.
Orange can be used for painting the entire cartridge housing, or as a strip. But this color is not in the table, and determining the cartridge's protection requires reading the inscription. Legislation requires the employer to select cartridges using only labels (not color markings).


European Union and Russia

In the European Union (EU) and the Russian Federation (RF), manufacturers can certify cartridges intended for cleaning the air of various gaseous contaminants. The codes are covered by EN14387, additionally particulate codes P1, P2 and P3 are used. For example, A1P2 is the code for commonly used filters in industry and agriculture that provide protection against A-type gases and commonly occurring particulates.
Cartridges AX, SX, and NO not distinguish on the sorption capacity (as in the US) when they are classified and certified. If the cartridge is designed to protect from several different types of harmful gases, the label will list all designations in order. For example: A2B1, color - brown and grey. Other jurisdictions that use this style of classification include Australia/New Zealand (AS/NZS 1716:2012) and China (GB 2890:2009).


Detection of end of service life

Service lives of all types of cartridges are limited, therefore, the employer is obliged to replace them in a timely manner.


Old methods


Subjective reactions of users' sensory systems

The use of cartridges in the contaminated atmosphere leads to saturation of the sorbent (or the dryer — when using catalysts). The concentration of harmful gases in the purified air gradually increases. The ingress of harmful gases in the inhaled air can lead to a reaction in a user's sensory system: odor, taste, irritation of the respiratory system, dizziness, headaches, and other health impairments up to the loss of consciousness. These signs (known in the US as "warning properties" - p. 28) indicate that one must leave the polluted workplace area, and replace the cartridge with a new one. This can also be a symptom of a loose fit the mask to one's face and the leakage of unfiltered air through the gaps between the mask and the face. Historically, this method is the oldest. The advantages of this method – if harmful gases have warning properties at concentrations less than 1 Permissible exposure limit, PEL, the replacement will be produced on time (''in most cases, at least''); the application of this method does not require the use of special cartridges (more expensive) and accessories; replacement happens when one needs to do it – after the sorbent saturation, and without any calculations; the sorption capacity of the cartridges is fully expired (which reduces costs for respiratory protection). The disadvantage of this method is that some harmful gases have no warning properties. For example, there is a list of over 500 harmful gases in the Respirator Selection Guide and over 60 of them have no warning properties, and there is no such information for over 100 of them. So, if one uses warning properties to replace cartridges, this may lead to breathing air with an excess harmful gas concentration in some cases. The table contains a list of the chemicals that have no warning properties. If the threshold odor of pentaborane is 194 PEL; and if its concentration is only 10 PEL, one cannot timely change cartridges by using smell - they could be "used" forever'', but they cannot protect forever.'' The practice has shown that the presence of warning properties does not always lead to timely cartridge replacement. A study showed that on average 95% of a group of people have an individual threshold of olfactory sensitivity in the range of from 1/16 to 16 from the mean. This means that 2.5% of people will not be able to smell harmful gases at a concentration 16 times greater than the average threshold of perception of a smell. The threshold of sensitivity of different people can vary by two orders of magnitude. That is, 15% of people do not smell at concentrations four times higher than the sensitivity threshold. The value of threshold smell greatly depends on how much attention people pay to it, and on their health status. The sensitivity may be reduced, for example, due to Common cold, colds and other ailments. It turns out that a worker's ability to detect smell also depends on the nature of the work to be performed—if it requires concentration, a user may not react to the smell. Prolonged exposure to harmful gases (for example, hydrogen sulfide) at low concentrations can create olfactory fatigue which reduces sensitivity. In all of these cases, users can be exposed to harmful substances with concentrations larger than 1 PEL, and it may lead to the development of occupational diseases. This was the reason for the ban to use this method of cartridge replacement in the US since 1996 (the Occupational Safety and Health Administration OSHA standard).


Mass increase

To protect workers from carbon monoxide cartridges often use the catalyst hopcalite. This catalyst does not change its properties over time of use, but when it moistened, the degree of protection may be significantly reduced. Because water vapor is always present in the air, the polluted air is dehumidified in the cartridge (for use of the catalyst). Since the mass of water vapor in the polluted air is greater than the mass of harmful gases, trapping moisture from the air leads to a significantly higher increase in the mass of cartridges than the trapping gases. This is a substantial difference, and it can be used to determine whether to continue to use gas cartridges further without replacement. The cartridge is weighed, and a decision can be made based on the magnitude of increase of its mass. For example, the book describes gas cartridges (model "СО"), which were replaced after a weight gain (relative to initial) of 50 grams.


Other methods

The documents described Soviet cartridges (model "Г"), designed to protect from mercury. Their service life was limited to 100 hours of use (cartridges without particle filter), or 60 hours of use (cartridges with particle filter), after which it was necessary to replace the cartridge with a new one. The documents describe a non-destructive way to determine the remaining service life of new and used gas cartridges. Polluted air was pumped through the cartridge. The degree of purification of air depends on how much-unsaturated sorbent is in the cartridge, therefore, accurate measurement of gas concentration in the cleaned air allows one to estimate the amount of the unsaturated sorbent. Polluted air (1-Bromobutane, 1-bromobutane) was pumped for a very short time, and therefore, such tests do not reduce the service life considerably. The sorption capacity decreased due to absorption of this gas by about 0.5% of the sorption capacity of a new cartridge. The method was also used for 100% quality control of the cartridges manufactured by the English firm Martindale Protection Co. (10 microliters 1-bromobutane injected into the air stream), and to check the cartridges issued to workers in firms Waring, Ltd. and Rentokil, Ltd. This method was used in the Defence CBRN Centre, Chemical Defence Establishment in the early 1970s. The experts who developed this method, received a patent. The document briefly describes two methods to objectively evaluate the degree of saturation of the sorbent in the cartridges. It recommends using spectral and microchemical methods. The spectral method is based on determining the presence of harmful substances in the cartridge by sampling, with subsequent analysis on a special device (стилоскоп - ''on Russian''). A microchemical method is based on a layer-by-layer determination of the presence of harmful substances in the sorbent by sampling with subsequent analysis by chemical method. If the air is contaminated with the most toxic substances, the book recommends to limit the further duration of cartridge use, and it recommended to apply the spectral method (arsine and phosphine, phosgene, fluorine, organochloride, Organometallic chemistry, organometallic compounds), and microchemical methods (hydrogen cyanide, cyanogens). Unfortunately, in both cases, there is no description of how to extract a sample of the sorbent from the cartridge housing (the housing is usually not detachable), and use the cartridge after this test, if the test shows that it does not have a lot of saturated sorbents.


Modern methods

Cartridge certification provides a minimum value of their sorption capacity. US Occupational Safety and Health Administration, OSHA standard for 1,3-Butadiene indicates the specific service life of the cartridges.


Laboratory testing

If the company has a laboratory with the right equipment, specialists can skip the contaminated air through the cartridge and determine the degree of cleaning needed. This method enables one to determine the service life in an environment where the air is contaminated with a mixture of different substances that affect their capture with a sorbent (one affecting another capture). Service life calculation methods for such conditions have been developed relatively recently. However, this requires accurate information on concentrations of noxious substances, and they often are not permanent. Tests in laboratories can identify the balance of service life of cartridges after their use. If the remainder is large, similar cartridges in such circumstances can be used over a longer period of time. In some cases, a large balance allows the use of cartridges repeatedly. This method does not require accurate information on the concentrations of harmful substances. The cartridge replacement schedule is drawn upon the basis of the results of their testing in the laboratory. This method has a serious drawback. The company must have complex and expensive equipment and trained professionals to use it, which is not always possible. According to a poll, cartridges replacement in the US was carried out on the basis of laboratory tests in approximately 5% of all organizations. Research to determine whether it is possible to calculate the service life of respirator cartridges (if one know the conditions of their use) have been conducted in developed countries since the 1970s. This allows one to replace cartridges in a timely fashion without the use of sophisticated and expensive equipment.


Computer programs

The world's leading respirator manufacturers offered customers computer programs for calculating the service life already in the year 2000.
3M program allowed to calculate the service life of the cartridges exposed with more than 900 harmful gases and their combinations in 2013. The MSA program enables taking into account hundreds of gases and their combinations. The same program was developed by Scott and Dragerwerk. J. Wood developed a mathematical model and software which now allows one to calculate the service life of any cartridges with known properties. Now OSHA uses it in its Advisor Genius program. The merit of this way of replacing the cartridges is that it allows an employer to use normal, "common" cartridges, and if they have the exact data, they may replace them in time. The downside is that because of air contamination is often not constant, and the nature of the work to be performed is not always stable (that is, the flow of air through the cartridges is not permanent), it is recommended to use working conditions for calculations, equal to the worst case, for reliable protection. But in all other cases, cartridges will be replaced with a partially used sorbent. This increases the costs of respiratory protection due to more frequent cartridges replacement. In addition, calculation accuracy is reduced under very high relative humidity, because the mathematical model does not take into account some of the physical effects in such cases.


End-of-service-life indicators

If a cartridge has a device to warn the user of the approaching expiration of the service life (end-of-service-life indicator, ESLI), the indication can be used for timely replacement of cartridges. ESLI can be active or passive. A passive indicator often uses a sensor that changes color. This element is installed in the cartridge at some distance from the filtered air outlet so that the color change occurs before harmful gases begin to pass through the cartridge. An active indicator may use a light or an audible alarm to signal that a cartridge needs to be replaced. Passive end-of-service-life indicators ESLI-1925.jpg , Yablick 1925 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 05.jpg , ChemMotif 2000 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 12.jpg , THO 1998 & Linders Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 14.jpg , ТНО 2004 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 06.jpg , Dragerwerk 1986 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 15.jpg , Wallace 1975 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 16.jpg , Wallace 1975 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 17.jpg , Roberts 1976 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 18.jpg , China 2001 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 19.jpg , Dragerwerk 1957 Active indicators use light or an audible alarm for user notification that is triggered by a sensor that is usually installed in the cartridge. Such indicators allow one to replace the cartridges on time in any light and do not require the worker to pay attention to the color of the indicator. They can also be used by workers who badly distinguish different colors. Despite the presence of solutions for technical problems, and the availability of established certification requirements to the ESLI, during the period from 1984 (first certification standard with requirements for active ESLI) until 2013 not one cartridge with active ESLI was approved in the US. It turned out that the requirements for the cartridges are not quite exact, and employers are under no requirement to use these indicators specifically. Therefore, respirator manufacturers fear Failure#Commercial failures, commercial failure when selling new unusual products, although they continue to carry out research and development work in this area. Active end-of-service-life indicators: Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI.jpg , American Optical Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 02.jpg , Auergesellschaft 1989 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 03.jpg , Auergesellschaft 1989 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 04.jpg , Bernard 1998 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 07.jpg , Dragerwerk 1994 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 08.jpg , FOGS 1998 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 09.jpg , Geraetebau 1991 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 10.jpg , Shigematsu 2002 Индикатор для определения срока службы фильтра End of Service Life Indicator ESLI 11.jpg , Stetter 1991 Examination of respirator use in the US showed that over 200,000 workers may be exposed to excessive harmful gases due to late replacement of cartridges. So, the Laboratory of PPE (The National Personal Protective Technology Laboratory, NPPTL) at the National Institute for Occupational Safety and Health, NIOSH began to develop an active ESLI. After the completion of the work, its results will help establish clear legal requirements for employers to follow and resulting technology will be transferred to industry to use in new improved RPD.


Legal requirements

Since it is not always possible to replace cartridges in a timely manner through the #WarningP, use of their odor ets, Occupational Safety and Health Administration, OSHA has banned the use of this method. The employer is obliged to use only two ways to replace cartridges: on schedule, and by using ESLI (because only these methods provide reliable preservation of workers’ health). OSHA instructions to inspectors provides specific guidance on inspection of implementation of such requirements. On the other hand, the state requires manufacturers to provide the consumer with all necessary information about cartridges to allow one to make a schedule for their timely replacement. Similar requirements exist in the standard on occupational safety, governing selection and application of RPD in EU. In England a tutorial on the selection and use of respirators recommends obtaining information from the manufacturer, and replacing the cartridges on a schedule or use ESLI, and prohibits reusing cartridges after exposure of volatile substances that can migrate. * The US law required the employer to use exceptionally supplied air RPD (SAR) for protection against harmful gases that have no warning properties. The use of supplied air respirators may be the only way to reliably protect workers in circumstances when there is no ESLI, and it is impossible to calculate their service life. * Legislation in the EU allows an employer to use only supplied air respirators when employees work in conditions where air pollution is IDLH, because of the risk of untimely cartridge replacement.


Reuse

If the cartridge contains a lot of the sorbent and if the concentration of contaminants is low; or if the cartridge was used for a short duration of time, after completion of its use, it still has a lot of unsaturated sorbent (which can capture gases). This may allow using such cartridges again. The molecules of an entrapped gases may de-absorb during storage of the cartridge. Due to the difference of concentrations inside the body of the cartridge (at the inlet concentration is greater; at the outlet for purified air concentration is lesser), these de-absorbed molecules migrate inside the cartridge to the outlet. The study of cartridges exposed to Bromomethane, methyl bromide showed that this migration can impede the re-use of storage. Concentration of harmful substances in the purified air may exceed the PEL (even if clean air is pumped through the cartridge). To protect worker health, US law prohibits cartridge reuse when exposed to harmful substances that can migrate, even if the cartridge has much non-saturated sorbent after the first use. According to the standards, "volatile" substances (those able to migrate) are considered substances with a boiling point below 65 °C. But studies have shown that at the boiling point above 65 °C reuse of the cartridge may be unsafe. Therefore, the manufacturer must provide the buyer with all information required for safe cartridge use. So, if the period of continuous service life of the cartridge (calculated by the program - see above) exceeds eight hours (see tables 4 and 5), the legislation may limit their use to one shift. The paper provides a procedure for calculating the concentration of harmful substances in purified air at the start of cartridge reuse which allows one to determine exactly where they may be safely reused. But these scientific results are not yet reflected in any standards or guidelines on respirator use. The author of the article, working in the US, did not even try to consider the use of gas cartridges more than twice. On the author's website one can download a free computer program that allows one to calculate concentration of harmful substances immediately after the start of re-use of the cartridge (which allows one to determine if it is safe).


Regenerating gas cartridges

Activated carbon does not bond with harmful gases strongly, so they can be released later. Other sorbents undergo chemical reactions with the hazard and form strong bonds. Special technologies have been developed for recovery of used cartridges. They created conditions that have stimulated desorption caught earlier harmful substances. This used steam or heated air in the 1930s or other methods. Processing of the sorbent was carried out after its removal from the body of the cartridge, or without removing. Specialists tried to use ion-exchange resin as the absorber in 1967. The authors proposed to regenerate the sorbent by washing it in a solution of alkali or soda. The study also showed that cartridges can be effectively regenerated after exposure to methyl bromide (when they are blown with hot air 100 to 110 °C, flow rate 20 L/min, duration about 60 minutes). Regeneration of sorbents is used consistently and systematically in the chemical industry, as it allows cost savings on the replacement of sorbent and regeneration of industrial gas cleaning devices to be carried out thoroughly and in an organized manner. However, in the mass use of gas masks under different conditions it is impossible to control the accuracy and correctness such regeneration of respirators’ cartridges. Therefore, despite the technical feasibility and commercial benefits, regeneration of respirator cartridges in such cases is not carried out.


References

{{reflist, refs= {{cite book, last1=Дубинин , first1= Михаил, last2=Чмутов К., title=Физико-химические основы противогазного дела // ''Physico-chemical bases of development and application of gas masks'' , year=1939, publisher=Военная академия химической защиты имени К.Е. Ворошилова, location=Moscow, language=ru .{{cite book , last1=David S. DeCamp, Joseph Costantino, Jon E. Black , title=Estimating Organic Vapor Cartridge Service Life , date=November 2004 , publisher=Air Force Institute for Operational Health Risk Analysis Directorate , location=Kennedy Circle Brooks City-Base , pages=53 , url=https://apps.dtic.mil/dtic/tr/fulltext/u2/a439710.pdf , archive-url=https://web.archive.org/web/20191005161425/https://apps.dtic.mil/dtic/tr/fulltext/u2/a439710.pdf , url-status=live , archive-date=October 5, 2019 , access-date=9 November 2019 , language=en {{Cite web, url=https://www.osha.gov/SLTC/etools/respiratory/change_schedule.html, title=Respirator Change Schedules ''(Respiratory Protection eTool)'', author=Occupational Safety and Health Administration, website=www.osha.gov, date=2019, location=200 Constitution Ave NW Washington, DC 20210, language=en, access-date=2019-12-08 {{cite book, last1=Bollinger, first1=Nancy , title=NIOSH Respirator Selection Logic, url=https://www.cdc.gov/niosh/docs/2005-100/, series=NIOSH-Issued Publications, date=October 2004, publisher=National Institute for Occupational Safety and Health, location=Cincinnati, OH , display-authors=etal, doi=10.26616/NIOSHPUB2005100 {{cite book, title=2008 Respirator Selection Guide, year=2008, publisher=3M, location=St. Paul, MN, pages=15–96 {{cite book, last1=Bollinger, first1=Nancy, last2=Schutz, first2=Robert, title=A Guide to Industrial Respiratory Protection, url=https://www.cdc.gov/niosh/docs/87-116/, series=NIOSH-Issued Publications, year=1987, publisher=National Institute for Occupational Safety and Health, location=Cincinnati, OH , display-authors=etal, doi=10.26616/NIOSHPUB87116 {{cite journal, last=Amoore, first=John, author2=Hautala Earl, year=1983, title=Odor as an aid to chemical safety: odor thresholds compared with threshold limit values and volatilities for 214 industrial chemicals in air and water dilution, journal=Journal of Applied Toxicology, volume=3, issue=6, pages=272–290, issn=1099-1263, doi=10.1002/jat.2550030603, pmid=6376602, s2cid=36525625 US OSHA occupational health and safety standard 29 Code of Federal Register 1910.1051 1,3-Butadien
''1910.1051(h)(3) Respirator selection''
/ref> {{cite book, last=U.S. Department of Labor, Bureau of Labor Statistics, title=Respirator Usage in Private Sector Firms, url=https://www.cdc.gov/niosh/docs/respsurv/pdfs/respsurv2001.pdf, year=2003, publisher=U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, location=Morgantown, WV, pages=214 (table 91) {{cite book, last1=ZieglerG. , first1= Martin , last2=Hauthal W. , last3=Koser H. , title=Entwicklung von Indikatoren zur Anzeige des Gebrauchsdauer-Endes von Gasfiltern (Machbarkeitsstudie), edition=1, series=Forschung Fb 997, year=2003, publisher=Wirtschaftsverl, location=Bremerhaven, language=de, isbn=978-3-86509-041-6 {{cite journal, last=Cothran T., year=2000, title=Features - Service Life Software for Organic Vapour Cartridges, journal=Occupational Health and Safety, volume=69, issue=5, pages=84–93, issn=0362-4064 The link to the document describing the progra
MerlinTM
{{Webarchive, url=https://web.archive.org/web/20160304063250/http://www.aearo.com/pdf/CHANGE.pdf , date=2016-03-04 . Unfortunately, the product could not be found.
Old link
Program for Cartridge Service Life calculation ezGuide
/ref> Link to the manufacturer's website where You can download a program to calculate the life of the cartridges
S-Series - Software Downloads
an
T-Series - Software Downloads

until January 1, 2016.
MSA program Cartridge Life Calculato
link 1link 2
(for US)
Link to a databas
VOICE
developed by Drager (''version for US'') with the program for calculation cartridge service life ''End-of-ServiceLife Calculator''
The program for calculation of service life of respirator cartridges that use a mathematical model of Jerry Wood

/ref> The program for calculation of service life of respirator cartridges, developed by Scott
SureLife™ Cartridge Calculator
{{Webarchive, url=https://web.archive.org/web/20090608165352/http://www.scottsurelife.com/DesktopUI/Login.aspx?RegionId=MQ

-PMHQ7K9J3Kg= , date=2009-06-08
US NIOSH occupational safety and health standard 42 Code of Federal Register 84 Approval of Respiratory Protective Device
‘’84.255 Requirements for end-of-service-life indicator.‘’
/ref> {{cite book, last=Favas, first=George , title=End of Service Life Indicator (ESLI) for Respirator Cartridges. Part I: Literature Review, url=http://www.dtic.mil/cgi-bin/GetTRDoc?Location=U2&doc=GetTRDoc.pdf&AD=ADA446250, archive-url=https://web.archive.org/web/20130502032450/http://www.dtic.mil/cgi-bin/GetTRDoc?Location=U2&doc=GetTRDoc.pdf&AD=ADA446250, url-status=dead, archive-date=May 2, 2013, date=July 2005, publisher=Human Protection & Performance Division, Defence Science and Technology Organisation, location=Victoria 3207 Australia, page=49 Computer progra

- Immediate Breakthrough Upon Reuse
BS 4275:1997 Guide to implementing an effective respiratory protective device programme DIN EN 529:2006. Atemschutzgerate - Empfehlungen fur Auswahl, Einsatz, Pflege und Instandhaltung. US OSHA occupational safety and health standard 29 Code of Federal Register 1910.13
Respiratory Protection
/ref> Charles Jeffress (OSHA
Instruction CPL 2-0.120
(1998)
EN 529-2005 Respiratory protective devices - Recommendations for selection, use, care and maintenance - Guidance document {{cite book, last=HSE, title=Respiratory protective equipment at work. A practical guide, url=http://www.hse.gov.uk/Pubns/priced/hsg53.pdf, edition=4, year=2013, publisher=Health and Safety Executive , isbn=978-0-7176-6454-2 NPPTL presentation (2007
Sensor Development for ESLI & Application to Chemical Detection
/ref> {{cite book, last=Myers, first=Warren, editor=Donald Miller, title=NIOSH Respirator Decision Logic, chapter-url=https://www.cdc.gov/niosh/docs/87-108/, series=DHHS (NIOSH) Publication No. 87-108, year=1987, publisher=National Institute for Occupational Safety and Health, location=Cincinnati, Ohio, pages=48–50, chapter=Appendice C. Odor warning: Background information., display-authors=etal {{cite book, last1=Clayton G.D., last2=Clayton E.F, title=Patty's Industrial Hygiene and Toxicology, edition=3, volume=1, year=1985, publisher=Willey-Interscience, location=New York, isbn=978-0-471-01280-1, page=1008 42 Code of Federal Register 84 Approval of respiratory protective device
§84.113 — Canisters and cartridges; color and markings; requirements
{{Webarchive, url=https://web.archive.org/web/20160312111808/http://cfr.regstoday.com/42cfr84.aspx#42_CFR_84p113 , date=2016-03-12
{{cite book, last=Rosenstock, first=Linda , title=TB Respiratory Protection Program In Health Care Facilities, chapter-url=https://www.cdc.gov/niosh/docs/99-143/, series=DHHS (NIOSH) Publication No. 99-143, year=1999, publisher=National Institute for Occupational Safety and Health, location=Cincinnati, Ohio, pages=42–44, chapter=Appendix A, display-authors=etal RF state standard ГОСТ
12.4.193-99
{{Webarchive, url=https://web.archive.org/web/20150630031338/http://www.ohranatruda.ru/ot_biblio/gost/6976.php?sphrase_id=1681487 , date=2015-06-30 Occupational safety standards system. Respiratory protective devices. Gas filters and combined filters. General specifications (''on Russian'')
RF state standard ГОСТ
12.4.231-2007
{{Webarchive, url=https://web.archive.org/web/20150630043316/http://www.ohranatruda.ru/ot_biblio/gost/680.php?sphrase_id=1681114 , date=2015-06-30 Occupational safety standards system. Respiratory protective devices. АX gas filters and combined filters for protection against low-boiling organic compounds. General specifications (''on Russian'')
RF state standard ГОСТ
12.4.232-2007
{{Webarchive, url=https://web.archive.org/web/20150630042537/http://ohranatruda.ru/ot_biblio/gost/1172.php?sphrase_id=4581064 , date=2015-06-30 Occupational safety standards system. Respiratory protective devices. SX gas filters and combined filters for protection against specific named compounds. General specifications (''on Russian'')
RF state standard ГОС
12.4.235-2012
(EN 14387:2008) Occupational safety standards system. Respiratory protective devices. Gas filters and combined filters. General technical requirements. Test methods. Marking (''on Russian'')
RF state standard ГОС
12.4.245-2013
Occupational safety standards system. Respiratory protective devices. Gas filters and combined filters. General specifications (''on Russian'')
{{cite book, editor=Michael E. Barsan, title= NIOSH Pocket guide to chemical hazards, url=https://www.cdc.gov/niosh/docs/2005-149/, edition=3, series=DHHS (NIOSH) Publication No. 2005-149, year=2007, publisher=National Institute for Occupational Safety and Health, location=Cincinnati, Ohio, pages=xiv–xvi; xx–xxiii; 2–340 {{cite journal, last=Wood, first=Gerry, author2=Jay Snyder, year=2007, title=Estimating Service Lives of Organic Vapor Cartridges III: Multiple Vapors at All Humidities, journal=Journal of Occupational and Environmental Hygiene, volume=4, issue=5, pages=363–374, issn=1545-9632, doi=10.1080/15459620701277468, pmid=17454504, s2cid=12914878 , url=https://zenodo.org/record/1234513 {{cite journal, last1=Maggs, first1=F. A. P., last2=Smith, first2=M. E., title=The Use and Regeneration of Type-O Canisters for Protection Against Methyl Bromide, journal=Annals of Occupational Hygiene, volume=18, issue=2, year=1975, pages=111–119, issn=0003-4878, doi=10.1093/annhyg/18.2.111, pmid=1059379 {{cite journal, last1=Wood, first1=Gerry O., last2=Snyder, first2=Jay L., title=Estimating Reusability of Organic Air-Purifying Respirator Cartridges, journal=Journal of Occupational and Environmental Hygiene, volume=8, issue=10, year=2011, pages=609–617, issn=1545-9624, doi=10.1080/15459624.2011.606536, pmid=21936700, s2cid=40470245 {{cite book, last1=Трумпайц Я.И., last2=Афанасьева Е.Н., title=Индивидуальные средства защиты органов дыхания (альбом) // ''Respiratory Protective Devices (album-catalogue)'' , year=1962 , publisher=Профиздат , location=Leningrad , language=ru {{cite book, last1=Шкрабо М.Л., title=Промышленные противогазы и респираторы. Каталог. // ''Industrial Respiratory Protective Devices. Catalogue.'' , year=1982, publisher=Отделение НИИТЭХИМа, location= Cherkassy, language=ru, display-authors=etal {{cite book, last1=Ballantyne , first1=Bryan, last2=Schwabe , first2=Paul, title=Respiratory Protection. Principles and Applications, year=1981, publisher=Chapman & Hall, location=London, New York, language=en, isbn=978-0412227509, display-authors=etal {{cite journal, last=Maggs F.A.P, year=1972, title=A Non-destructive Test of Vapour Filters, journal=The Annual of Occupational Hygiene, volume=15, issue=2–4, pages=351–359, issn=1475-3162, doi=10.1093/annhyg/15.2-4.351, pmid=4648247, language=en British Patent No 60224/69 {{cite book, last1=Тихова Т.С., editor=Капцов В.А., title=Средства индивидуальной защиты работающих на железнодорожном транспорте. Каталог-справочник // ''Personal protective equipment for railway workers. Сatalogue-guidebook'' , publisher=ВНИИЖГ, Транспорт, location=Moscow, page=245, language=ru, display-authors=etal {{cite book, last=Торопов, first=Сергей, title=Испытания промышленных фильтрующих противогазов // The testing of industrial air purifying respirators , year=1938, publisher=Государственное научно-техническое издательство технической литературы НКТП. Редакция химической литературы , location=Moscow, language=ru {{cite book, last=Торопов, first=Сергей, title=Промышленные противогазы и респираторы // Industrial gas masks and respirators , year=1940, publisher=Государственное научно-техническое издательство технической литературы, location=Moscow Leningrad, language=ru {{cite journal, last=Руфф ВТ, year=1936, title=Регенерация промышленных фильтрующих противогазов // ''Regeneration of cartridges from industrial RPD'', journal=Гигиена труда и техника безопасности // Occupational Health and Safety , issue=1, pages=56–60, language=ru {{cite journal, author1=Вулих А.И. , author2=Богатырёв В.Л. , author3=Загорская М.К. , author4=Шивандронов Ю.А. , year=1967, title=Иониты в качестве поглотителей для противогазов // ''The ion exchangers as a sorbent for respirator cartridges'' , journal=Безопасность труда в промышленности // Occupational Safety in Industry , issue=1, pages=46–48, issn=0409-2961, language=ru {{cite book, last1=Rose-Pehrsson, first1=Susan L., last2=Williams, first2=Monica L., title=Integration of Sensor Technologies into Respirator Vapor Cartridges as End-of-Service-Life Indicators: Literature and Manufacturer's Review and Research Roadmap, url=http://oai.dtic.mil/oai/oai?verb=getRecord&metadataPrefix=html&identifier=ADA434905, year=2005, publisher=US Naval Research Laboratory, location=Washington, DC, page=37, access-date=2015-06-27, archive-url=https://web.archive.org/web/20160304053447/http://oai.dtic.mil/oai/oai?verb=getRecord&metadataPrefix=html&identifier=ADA434905, archive-date=2016-03-04, url-status=dead Magnante P.C. (1979) Respirator cartridge end-of-service life indicator, American Optical Corporation

/ref> Freidank M., Coym J. and Schubert A. (1989) Warning device to indicate the state of gases exhaustion of a gas filter retaining dangerous gases, Auergesellschaft GMBH

/ref> Bernard P., Caron S., St. Pierre M. and Lara, J. (2002) End-of-service indicator including porous waveguide for respirator cartridge, Institut National D’Optique, Quebec, Patent No
US6375725
/ref> Shigematsu Y., Kurano R. and Shimada S. (2002) Gas mask having detector for detecting timing to exchange absorption can, Shigematsu Works Co Ltd and New Cosmos Electric Corp., Patent No. JP2002102367. {{cite journal, last =Maclay G.J., Yue C., Findlay M.W. and Stetter J.R , title=A prototype active end-of-service-life indicator for respirator cartridges , language=en, journal=Applied Occupational and Environmental Hygiene, publisher=Taylor and Francis, year=2001, volume=6, issue=8, pages=677–682, issn=1047-322X , doi=10.1080/1047322X.1991.10387960 Stetter J.R. and Maclay G.J. (1996) Chemical sensing apparatus and methods, Transducer Research Inc.

/ref> Linders M.J.G., Bal E.A., Baak P.J., Hoefs J.H.M. and van Bokhoven J.J.G.M. (2001
Further development of an end of service life indicator for activated carbon filters
Carbon '01, University of Kentucky Center for Applied Energy Research, Lexington, Kentucky, United States
Jager H. and Van de Voorde M.J. (1999) Device for removing one or more undesirable or dangerous substances from a gas or vapor mixture and a gas mask comprising such a device, Nederlandse Organisatie Voor Toegepastnatuurwetenschappelijk Onderzoek TNO

/ref> Leichnitz K. (1987) Colorimetric indicator for the indication of the exhaustion of gas filters, Dragerwerk AG, Germany

/ref> Wallace R.A. (1975) Chemically activated warning system, Wallace, R. A., Patent No

Wallace R.A. (1975) Thermally activated warning system, Patent No

/ref> Roberts C.C. (1976) Colorimetric vinyl chloride indicator, Catalyst Research Corporation

Dragerwerk H. and Bernh, D. L. (1957), Patent No. GE962313 Yablick M. (1925) Indicating gas-mask canister, Patent No
US1537519
/ref> Safety equipment Respirators