Cat‑5
   HOME

TheInfoList



OR:

Category 5 cable (Cat 5) is a twisted pair cable for computer networks. Since 2001, the variant commonly in use is the Category 5e specification (Cat 5e). The cable standard provides performance of up to 100 MHz and is suitable for most varieties of Ethernet over twisted pair up to 2.5GBASE-T but more commonly runs at (Gigabit Ethernet) speeds. Cat 5 is also used to carry other signals such as telephone and video. This cable is commonly connected using punch-down blocks and modular connectors. Most Category 5 cables are unshielded, relying on the
balanced line In telecommunications and professional audio, a balanced line or balanced signal pair is a circuit consisting of two conductors of the same type, both of which have equal impedances along their lengths and equal impedances to ground and to other ...
twisted pair design and differential signaling for noise rejection.


Standards

The specification for category 5 cable is defined in ISO/IEC 11801,
IEC 61156 The International Electrotechnical Commission (IEC; in French language, French: ''Commission électrotechnique internationale'') is an international standards organization that prepares and publishes international standards for all electrical, ...
and
EN 50173 En or EN may refer to: Businesses * Bouygues (stock symbol EN) * Esquimalt and Nanaimo Railway (reporting mark EN, but now known as Southern Railway of Vancouver Island) * Euronews, a news television and internet channel Language and writing * ...
. The specification for category 5 cable was defined in ANSI/ TIA/EIA-568-A, with clarification in TSB-95. These documents specify performance characteristics and test requirements for
frequencies Frequency is the number of occurrences of a repeating event per unit of time. It is also occasionally referred to as ''temporal frequency'' for clarity, and is distinct from ''angular frequency''. Frequency is measured in hertz (Hz) which is eq ...
up to 100 MHz. The cable is available in both stranded and solid conductor forms. The stranded form is more flexible and withstands more bending without breaking.
Patch cable A patch cable, patch cord or patch lead is an electrical or optical cable used to connect ("patch in") one electronic or optical device to another for signal routing. Devices of different types (e.g., a switch connected to a computer, or a sw ...
s are stranded. Permanent wiring used in
structured cabling In telecommunications, structured cabling is building or campus cabling infrastructure that consists of a number of standardized smaller elements (hence structured) called subsystems. Structured cabling components include twisted pair and opti ...
is solid-core. The category and type of cable can be identified by the printing on the jacket. The category 5 specification requires conductors to be pure copper. The industry has seen a rise in non-compliant / counterfeit cables, especially of the Copper Clad Aluminum (CCA) variety. This has exposed the manufacturers or installers of such fake cable to legal liabilities.


Variants and comparisons

The category 5e specification improves upon the category 5 specification by revising and introducing new specifications to further mitigate the amount of
crosstalk In electronics, crosstalk is any phenomenon by which a signal transmitted on one circuit or channel of a transmission system creates an undesired effect in another circuit or channel. Crosstalk is usually caused by undesired capacitive, induc ...
. The bandwidth (100 MHz) and physical construction are the same between the two, and most Cat 5 cables actually meet Cat 5e specifications, though they are not specifically certified as such. The category 5 was deprecated in 2001 and superseded by the category 5e specification. The Category 6 specification improves upon the Category 5e specification by extending frequency response and further reducing crosstalk. The improved performance of Cat 6 provides 250 MHz bandwidth. Category 6A cable provides 500 MHz bandwidth. Both variants are backward compatible with Category 5 and 5e cables.


Termination

Cable types, connector types and cabling topologies are defined by ANSI/TIA-568. Nearly always, 8P8C modular connectors (often referred to incorrectly as
RJ45 A modular connector is a type of electrical connector for cords and cables of electronic devices and appliances, such as in computer networking, telecommunication equipment, and audio headsets. Modular connectors were originally developed for ...
connectors) are used for connecting category 5 cable. The cable is terminated in either the
T568A ANSI/TIA-568 is a technical standard for commercial building cabling for telecommunications products and services. The title of the standard is ''Commercial Building Telecommunications Cabling Standard'' and is published by the Telecommunications I ...
scheme or the T568B scheme. The two schemes work equally well and may be mixed in an installation so long as the same scheme is used on both ends of each cable.


Applications

Category 5 cable is used in structured cabling for computer networks such as Ethernet over twisted pair. The cable standard prescribes performance parameters for frequencies up to and is suitable for , (Fast Ethernet), (Gigabit Ethernet), . and Ethernet connections require two wire pairs. 1000BASE-T and faster Ethernet connections require four wire pairs. Through the use of power over Ethernet (PoE), power can be carried over the cable in addition to Ethernet data. Cat 5 is also used to carry other signals such as telephony and video. In some cases, multiple signals can be carried on a single cable; Cat 5 can carry two conventional telephone lines as well as 100BASE-TX in a single cable. The USOC/RJ-61 wiring standard may be used in multi-line telephone connections. Various schemes exist for transporting both analog and digital video over the cable.
HDBaseT HDBaseT is a consumer electronic (CE) and commercial connectivity standard for transmission of uncompressed ultra-high-definition video, digital audio, DC power, Ethernet, USB 2.0, and other control communication (such as RS-232 and Consume ...
is one such scheme.


Characteristics

The use of
balanced line In telecommunications and professional audio, a balanced line or balanced signal pair is a circuit consisting of two conductors of the same type, both of which have equal impedances along their lengths and equal impedances to ground and to other ...
s helps preserve a high
signal-to-noise ratio Signal-to-noise ratio (SNR or S/N) is a measure used in science and engineering that compares the level of a desired signal to the level of background noise. SNR is defined as the ratio of signal power to the noise power, often expressed in deci ...
despite interference from both external sources and crosstalk from other pairs.


Insulation

Outer insulation is typically polyvinyl chloride (PVC) or low smoke zero halogen (LS0H).


Bending radius

Most Category 5 cables can be bent at any radius exceeding approximately four times the outside diameter of the cable.


Maximum cable segment length

The maximum length for a cable segment is per TIA/EIA 568-5-A. If longer runs are required, the use of active hardware such as a repeater or switch is necessary. The specifications for 10BASE-T networking specify a 100-meter length between active devices. This allows for 90 meters of solid-core permanent wiring, two connectors and two stranded patch cables of 5 meters, one at each end.


Conductors

Since 1995, solid-conductor UTP cables for backbone cabling is required to be no thicker than 22 American Wire Gauge (AWG) and no thinner than 24 AWG, or 26 AWG for shorter-distance cabling. This standard has been retained with the 2009 revision of ANSI TIA/EIA 568. Although cable assemblies containing are common, category 5 is not limited to 4 pairs. Backbone applications involve using up to .


Individual twist lengths

The distance per twist is commonly referred to as pitch. Each of the four pairs in a Cat 5 cable has differing precise pitch to minimize
crosstalk In electronics, crosstalk is any phenomenon by which a signal transmitted on one circuit or channel of a transmission system creates an undesired effect in another circuit or channel. Crosstalk is usually caused by undesired capacitive, induc ...
between the pairs. The pitch of the twisted pairs is not specified in the standard. Measurements on one sample of Cat 5 cable yielded the following results. Since the pitch of the various colors is not specified in the standard, pitch can vary and should be measured for the batch being used if the cable is being used in a non-Ethernet situation where pitch may be critical.


Environmental ratings

Some cables are "UV-rated" or "UV-stable" meaning they can be exposed to outdoor UV radiation without significant degradation. Plenum-rated cables are slower to burn and produce less smoke than cables using a mantle of materials like PVC. Plenum-rated cables may be installed in plenum spaces where PVC is not allowed. Shielded cables ( FTP or STP) are useful for environments where proximity to RF equipment may introduce
electromagnetic interference Electromagnetic interference (EMI), also called radio-frequency interference (RFI) when in the radio frequency spectrum, is a disturbance generated by an external source that affects an electrical circuit by electromagnetic induction, electros ...
, and can also be used where eavesdropping likelihood should be minimized.


References


Further reading

* {{DEFAULTSORT:Category 5 Cable Ethernet cables Transmission lines