HOME

TheInfoList



OR:

The Cisco Catalyst 6500 is a modular chassis
network switch A network switch (also called switching hub, bridging hub, and, by the IEEE, MAC bridge) is networking hardware that connects devices on a computer network by using packet switching to receive and forward data to the destination device. A netw ...
manufactured by
Cisco Systems Cisco Systems, Inc., commonly known as Cisco, is an American-based multinational corporation, multinational digital communications technology conglomerate (company), conglomerate corporation headquartered in San Jose, California. Cisco develo ...
from 1999 to 2015, capable of delivering speeds of up to "400 million
packet Packet may refer to: * A small container or pouch ** Packet (container), a small single use container ** Cigarette packet ** Sugar packet * Network packet, a formatted unit of data carried by a packet-mode computer network * Packet radio, a form ...
s per second".Cisco Catalyst 6500 Series Supervisor Engine 720
/ref> A 6500 comprises a chassis, power supplies, one or two supervisors, line cards, and service modules. A chassis can have 3, 4, 6, 9, or 13 slots each (Catalyst model 6503, 6504, 6506, 6509, or 6513, respectively) with the option of one or two modular power supplies. The supervisor engine provides centralised forwarding information and processing; up to two of these cards can be installed in a chassis to provide active/standby or stateful
failover Failover is switching to a redundant or standby computer server, system, hardware component or network upon the failure or abnormal termination of the previously active application, server, system, hardware component, or network in a computer net ...
. The line cards provide port connectivity and service modules to allow for devices such as firewalls to be integrated within the switch.


Supervisor

The 6500 Supervisor comprises a
Multilayer Switch A multilayer switch (MLS) is a computer networking device that switches on Data link layer, OSI layer 2 like an ordinary network switch and provides extra functions on higher OSI model, OSI layers. The MLS was invented by engineers at Digital Eq ...
Feature Card (MSFC) and a Policy Feature Card (PFC). The MSFC runs all software processes, such as
routing protocol A routing protocol specifies how routers communicate with each other to distribute information that enables them to select routes between nodes on a computer network. Routers perform the traffic directing functions on the Internet; data packets ...
s. The PFC makes forwarding decisions in hardware. The supervisor has connections to the
switching fabric Switched fabric or switching fabric is a network topology in which network nodes interconnect via one or more network switches (particularly crossbar switches). Because a switched fabric network spreads network traffic across multiple physical li ...
and classic bus, as well as bootflash for the
Cisco IOS The Internetworking Operating System (IOS) is a family of proprietary network operating systems used on several router and network switch models manufactured by Cisco Systems. The system is a package of routing, switching, internetworking, and ...
software. The latest generation supervisor is 'Supervisor 2T'. This supervisor was introduced at Cisco Live Las Vegas in July 2011. It provides 80 gigabits per slot on all slots of 6500-E chassis.


Operating systems

The 6500 currently supports three operating systems: CatOS, Native IOS, and Modular IOS.


CatOS

CatOS Catalyst is the brand for a variety of network switches, wireless controllers, and wireless access points sold by Cisco Systems. While commonly associated with Ethernet switches, a number of different types of network interfaces have been avail ...
is supported for layer 2 (switching) operations only. And, able to perform routing functions (e.g. Layer 3) operations, the switch must be run in hybrid mode. In this case, CatOS runs on the Switch Processor (SP) portion of the Supervisor, and IOS runs on the Route Processor (RP), also known as the MSFC. To make configuration changes, user must then manually switch between the two environments. CatOS does have some missing functionality, andComparison of the Cisco Catalyst and Cisco IOS Operating Systems for the Cisco Catalyst 6500 Series Switch
/ref> is generally considered 'obsolete' compared to running a switch in Native Mode.


Native IOS

Cisco IOS The Internetworking Operating System (IOS) is a family of proprietary network operating systems used on several router and network switch models manufactured by Cisco Systems. The system is a package of routing, switching, internetworking, and ...
can be run on both the SP and RP. In this instance, the user is unaware of where a command is being executed on the switch, even though technically two IOS images are loaded—one on each processor. This mode is the default shipping mode for Cisco products and enjoys the support of all new features and line cards.


Modular IOS

Modular IOS is a version of Cisco IOS that employs a modern UNIX-based kernel to overcome some of the limitations of IOS.Cisco Catalyst 6500 Series with Cisco IOS Software Modularity
/ref> Additional to this is the ability to perform patching of processes without rebooting the device and in-service upgrades.


Methods of operation

The 6500 has five major modes of operation: Classic, cef256, dcef256, cef720, and dcef720.


Classic Bus

The 6500 classic architecture provides 32 Gbit/s centralised forwarding performance.Cisco Catalyst 6500 Supervisor Engine 32 Architecture
/ref> The design is such that an incoming packet is first queued on the line card and then placed on to the global data bus (dBus) and is copied to all other line cards, including the supervisor. The supervisor then looks up the correct egress port, access lists, policing, and any relevant rewrite information on the PFC. It is placed on the result bus (rBus) and sent to all line cards. Those line cards for which the data is not required terminate processing. The others continue forwarding and apply relevant egress queuing. The speed of the classic bus is 32gb
half duplex A duplex communication system is a point-to-point system composed of two or more connected parties or devices that can communicate with one another in both directions. Duplex systems are employed in many communications networks, either to allow ...
(since it is a shared bus) and is the only supported way of connecting a Supervisor 32 engine (or Supervisor 1) to a 6500.


cef256

This method of forwarding, was first introduced with the Supervisor 2 engine. When used in combination with a switch fabric module, each line card has an 8Gbit/s connection to the switch fabric and additionally a connection to the classic bus. In this mode, assuming all line cards have a switch fabric connection, an ingress packet is queued as before and its headers are sent along the dBus to the supervisor. They are looked up in the PFC (including ACLs etc.), then the result is placed on the rBus. The initial egress line card takes this information and forwards the data to the correct line card along with the switch fabric. The main advantage here is that, there is a dedicated 8 Gbit/s connection between the line cards. The receiving line card queues the egress packet before sending it from the desired port. The '256' is derived from a chassis using 2x8gb ports on 8 slots of a 6509 chassis: 16 * 8 = 128, 128 * 2 = 256. The number gets double because of the switch fabric being 'full duplex'.


dcef256

dcef256 uses distributed forwarding. These line cards have 2x8gb connections to the switch fabric and no classic bus connection. Only modules that have a DFC (Distributed Forwarding Card) can use dcef. Unlike the previous examples, the line cards hold a full copy of the supervisor's routing tables locally, as well as its L2 adjacency table (i.e.
MAC address A media access control address (MAC address) is a unique identifier assigned to a network interface controller (NIC) for use as a network address in communications within a network segment. This use is common in most IEEE 802 networking techno ...
es). This eliminates the need for any connection to the classic bus or the requirement to use the shared resource of the supervisor. In this instance, an ingress packet is queued, but its destination is looked up locally. The packet is then sent across the switch fabric and queued in the egress line card before being sent.


cef720

This mode of operation acts identically to cef256, except with 2x20gb connections to the switch fabric and there is no need for a switch fabric module (this is now integrated into the supervisor). This was first introduced into the Supervisor Engine 720. The '720' is derived from a chassis using 2x20gb ports on 9 slots of a 6509 chassis. 40 * 9 = 360 * 2 = 720. The number is doubled to the switch fabric being 'full duplex'. The reason 9 slots are used for the calculation instead of 8 for the cef256 is that it no longer needs to waste a slot with the switch fabric module.


dcef720

This mode of operation acts identically to dcef256, except with 2x20gb connections to the switch fabric.


Power supplies

The 6500 is able to deliver high densities of
Power over Ethernet Power over Ethernet, or PoE, describes any of several standards or ad hoc systems that pass electric power along with data on twisted-pair Ethernet cabling. This allows a single cable to provide both data connection and electrical power to d ...
across the chassis. Because of this, power supplies are the key elements of the configuration.


Chassis support

The following goes through the various 6500 chassis and their supported power supplies & loads.


6503

The original chassis permits up to 2800W and uses rear-inserted power supplies differ from the others in the series.


6504-E

This chassis permits up to 5000W (119A @ 42V) of power and, like the 6503, uses rear-inserted power supplies.


6506, 6509, 6506-E and 6509-E

The original chassis can support up to a maximum of 4000W (90A @ 42V) of power, because of backplane limitations. If a power supply above this is inserted, it will deliver at full power up to this limitation (i.e. a 6000W power supply is supported in these chassis, but will output a maximum of 4000W). The 6509-NEB-A supports a maximum of 4500W (108A @ 42V).  With the introduction of the 6506-E and 6509-E series chassis, the maximum power supported has been increased to over 14500 W (350A @ 42V).


6513

This chassis can support a maximum of 8000W (180A @ 42V). However, to obtain this, it must be run in combined mode. Therefore, it is suggested that it would be run in redundant mode to obtain a maximum of 6000W (145A @ 42V).


Power redundancy options

The 6500 supports dual power supplies for redundancy. These may be run in one of two modes: redundant or combined mode.


Redundant mode

When running in Redundant mode, each power supply provides approximately 50% of its capacity to the chassis. In the event of a failure, the unaffected power supply will then provide 100% of its capacity and an alert will be generated. As there was enough to power the chassis ahead of time, there is no interruption to service in this configuration. This is also the default and recommended way to configure power supplies.


Combined mode

In combined mode, each power supply provides approximately 83% of its capacity to the chassis. This allows for greater utilisation of the power supplies and potentially increased PoE densities. In systems that are equipped with two power supplies, if one power supply fails and the other power supply cannot fully power all of the installed modules, system power management will shut down devices in the following order: *Power over Ethernet (PoE) devices— The system will power down PoE devices in descending order, starting with the highest numbered port on the module in the highest numbered slot. *Modules—If additional power savings are needed, the system will power down modules in descending order, starting with the highest numbered slot. Slots containing supervisor engines or Switch Fabric Modules are bypassed and are not powered down. This shut down order is fixed and cannot be changed.


Online Insertion & Removal

''OIR'' is a feature of the 6500 which allows
hot swap Hot swapping is the replacement or addition of components to a computer system without stopping, shutting down, or rebooting the system; hot plugging describes the addition of components only. Components which have such functionality are said ...
ping of most line cards without first powering down the chassis. The advantage of this is that one may perform an in-service upgrade. However, before attempting this, it is important to understand the process of OIR and how it may still require a reload. To prevent bus errors, the chassis has three pins in each slot that correspond with the line card. Upon insertion, the longest of these makes first contact and stalls the bus (to avoid corruption). As the line card is pushed in further, the middle pin makes the data connection. Finally, the shortest pin removes the bus stall and allows the chassis to continue operation. However, if any part of this operation is skipped, errors will occur (resulting in a stalled bus and ultimately a chassis reload). Common problems include: * Line cards being inserted incorrectly (thus making contact with only the stall & data pins and thus not releasing the bus) * Line cards being inserted too quickly (thus the stall removal signal is not received) * Line cards are being inserted too slowly (thus the bus is stalled for too long & forces a reload).


See also

*
Supervisor Engine (Cisco) The Cisco Supervisor Engine is the brain of many of Cisco's switches. The Supervisor Engine has evolved several times. While it is the management segment of many routers, the power of the switch is often much greater than that of the Supervisor ...


References

{{Cisco Systems Cisco products