Backflow is a term in
plumbing Plumbing is any system that conveys fluids for a wide range of applications. Plumbing uses pipes, valves, plumbing fixtures, tanks, and other apparatuses to convey fluids. Heating and cooling (HVAC), waste removal, and potable water delivery ...
for an unwanted flow of water in the reverse direction. It can be a serious health risk for the contamination of
potable water Drinking water is water that is used in drink or food preparation; potable water is water that is safe to be used as drinking water. The amount of drinking water required to maintain good health varies, and depends on physical activity level, ag ...
supplies with foul water. In the most obvious case, a toilet flush cistern and its water supply must be isolated from the toilet bowl. For this reason,
building code A building code (also building control or building regulations) is a set of rules that specify the standards for constructed objects such as buildings and non-building structures. Buildings must conform to the code to obtain planning permission ...
s mandate a series of measures and
backflow prevention device A backflow prevention device is used to protect potable water supplies from contamination or pollution due to backflow. In water distribution systems, water is normally maintained at a significant pressure to enable water to flow from the tap, s ...
s to prevent backflow.


Causes

Backflow occurs for one of two reasons, either ''back pressure'' or ''back siphonage''. ''Back pressure'' is the result of a higher pressure in the system than in its supply, i.e. the system pressure has been ''increased'' by some means. This may occur in unvented heating systems, where thermal expansion increases the pressure. ''Back siphonage'' is the result of supply pressure being ''lowered'' below that of the system. This may occur when a supply is interrupted or drained down.


Risk of contamination

The precise measures required to prevent backflow depend on the risk of contamination, i.e. the condition of the water in the connected system. This is categorized into different risk levels: * Category 1: No risk. Potable water * Category 2: Aesthetic quality affected, e.g. water which may have been heated * Category 3: Slight hazard from substances of low toxicity, e.g. cold water storage tanks * Category 4: Significant hazard, e.g. pesticides * Category 5: Serious health risk, e.g. human waste


Measures to avoid backflow

Backflow prevention must be automatic, and manually-operated valves are not usually acceptable.


Check valves

Automatic
check valve A check valve, non-return valve, reflux valve, retention valve, foot valve, or one-way valve is a valve that normally allows fluid (liquid or gas) to flow through it in only one direction. Check valves are two-port valves, meaning they have t ...
s are required to prevent back pressure. Regulations for these check valves specify the design capabilities of the valve used, according to the hazard. Category 2 contamination may be prevented by a single check valve, but category 3 requires a
double check valve A double check valve or double check assembly (DCA) is a backflow prevention device designed to protect water supplies from contamination. It is different from the two-way check valves (sometimes erroneously referred to as double check valves) u ...
(these are manufactured as a convenient single unit, or even integrated into tap (faucet) fittings). Category 5 requires an air gap, not merely a valve. A recent introduction to the UK has been the Reduced Pressure Zone (RPZ) valve, a form of double check valve where the intervening zone is drained and normally kept empty. If the downstream valve leaks and permits backflow, this will drain out through the vent rather than building up pressure against the upstream valve. These valves are complex, requiring certified installation and annual checks. They are used for category 4 systems, such as
fire sprinkler A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively use ...
s where the system has an antifreeze additive.


Air gaps

Back siphonage may be prevented by use of a vertical air gap. This may be a small gap, such as provided by a
tundish The word tundish originates from a shallow wooden dish with an outlet channel, fitting into the bunghole of a tun or cask and forming a kind of funnel for filling it. These were originally used in brewing. In general, any tundish will accept flow ...
(a combined overflow spout and catch funnel) or a large gap, such as a basin tap being above the maximum level of the water in the basin. Standards for these air gaps group them by the amount of separation that they provide and their acceptability for the various risk categories. The size of the acceptable gap also depends on the capacity of the incoming supply, such that a stuck-open flow cannot overfill the cistern and close the gap. Air gaps may also protect against back pressure, and are generally favoured for this. However most air gaps also limit the system pressure that may be transmitted across them. In most cases they replace mains pressure with the pressure of that from a raised gravity cistern. Common examples of an air gap in domestic plumbing are: * Taps above washbasins * Cold water
cistern A cistern (Middle English ', from Latin ', from ', "box", from Greek ', "basket") is a waterproof receptacle for holding liquids, usually water. Cisterns are often built to catch and store rainwater. Cisterns are distinguished from wells by t ...
s, where the
float valve A ballcock (also balltap or float valve) is a mechanism or machine for filling water tanks, such as those found in flush toilets, while avoiding overflow and (in the event of low water pressure) backflow. The modern ballcock was invented by Josà ...
outlet must be above the overflow water level. The previous practice of taking a "silencing tube" from the float valve to under the water level is no longer acceptable. Under some plumbing codes. such silencing may still be acceptable if it is a soft collapsible tube which cannot syphon. * Hand-held
shower A shower is a place in which a person bathes under a spray of typically warm or hot water. Indoors, there is a drain in the floor. Most showers have temperature, spray pressure and adjustable showerhead nozzle. The simplest showers have a ...
s must have their hoses fastened such that the shower head cannot rest below the water level in a bath or basin.


Sanitary sewer backflow

Backwater sanitary valves (also known as "check valves" or "backwater valves") are also often referred to as "backflow preventers" They are intended to prevent backflow of
sewage Sewage (or domestic sewage, domestic wastewater, municipal wastewater) is a type of wastewater that is produced by a community of people. It is typically transported through a sewer system. Sewage consists of wastewater discharged from residenc ...
on the sanitary sewer line during a flood or sewer blockage, and have no connection with potable water. Also sewage lifting stations provide comprehensive protection against sewer backflow. They pump the water above the backpressure level into the sewer. Even when the sewer is completely full. Sunday, 21 February 2021