Air-mixing Plenum
   HOME

TheInfoList



OR:

In
building services engineering Building services engineering is a professional engineering discipline that strives to achieve a safe and comfortable indoor environment whilst minimizing the environmental impact of a building. Alternative titles are "building services engineerin ...
and
HVAC Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HV ...
, an air-mixing plenum (or mixing box) is used for mixing air from different
ductwork Ducts are conduits or passages used in heating, ventilation, and air conditioning (HVAC) to deliver and remove air. The needed airflows include, for example, ''supply air'', ''return air'', and ''exhaust air''. Ducts commonly also deliver '' v ...
systems.


Usage

The most common application for an air-mixing plenum is the mixing of ''return air'' (or ''extract air'') with fresh air to provide a supply air mixture for onward distribution to the building or area which the ventilation system is serving. The air transferred from the return air stream to the supply air stream is termed ''recirculated air''. All air not mixed is rejected to the atmosphere as ''exhaust air''. Air streams are mixed to save energy and improve
energy efficiency Energy efficiency may refer to: * Energy efficiency (physics), the ratio between the useful output and input of an energy conversion process ** Electrical efficiency, useful power output per electrical power consumed ** Mechanical efficiency, a ra ...
.


Operation

The mixing plenum normally combines two air streams, and includes for three sets of dampers: one for the fresh air, one for the exhaust air, and a mixing damper between the two air streams. The mix of fresh air and recirculated air can thus be adjusted to suit the needs of the building's occupants. Most systems will use motorized dampers to control the air mixing, and controlled by the building management system (BMS), or controls system. Typically as the fresh air and exhaust air dampers are driven from 0% open to 100% open, the mixing damper will in turn be driven from 100% open to 0% open, so as to always ensure a constant volume of supply and extract air.


Energy efficiency

Air supply to a building is generally performed by an
air handling unit An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system. An air handler is usually a large metal box containing a blowe ...
. The process may include for filtering, heating, cooling, humidification, or dehumidification, all of which processes consume energy. Since the fresh air demand for the building occupants may be less than that is required for air conditioning purposes, it would be wasteful if 100% fresh air were used, with wholesome treated air rejected to the atmosphere in its place. Therefore, mixing is used to balance the needs between the occupants requirements for fresh air and the air conditioning process for the building. Enhanced controls systems may monitor the return air quality or
carbon dioxide Carbon dioxide (chemical formula ) is a chemical compound made up of molecules that each have one carbon atom covalently double bonded to two oxygen atoms. It is found in the gas state at room temperature. In the air, carbon dioxide is transpar ...
concentration in order to automatically modulate the air mix for optimum energy efficiency whilst maintaining desired fresh air requirements. Such systems work very well in buildings where the occupancy rate can vary greatly throughout the day, or seasonally. Additionally, when outside air conditions are such, typically mid-season weather conditions, it may be that ambient temperatures are suitable for
free cooling Free cooling is an economical method of using low external air temperatures to assist in chilling water, which can then be used for industrial processes, or air conditioning systems. The chilled water can either be used immediately or be stored fo ...
purposes. In such conditions the mixing damper will be set to close and the system use full fresh air for optimum energy efficiency. Where fresh air is not required, such as early morning pre-heat or pre-conditioning periods, the mixing damper can be automatically set to full recirculation, again for optimum energy efficiency.


References

{{HVAC Ventilation Heating, ventilation, and air conditioning Building biology Fluid dynamics