Auxiliary Power
   HOME

TheInfoList



OR:

Auxiliary power is
electric power Electric power is the rate at which electrical energy is transferred by an electric circuit. The SI unit of power is the watt, one joule per second. Standard prefixes apply to watts as with other SI units: thousands, millions and billions o ...
that is provided by an alternate source and that serves as backup for the primary power source at the station main
bus A bus (contracted from omnibus, with variants multibus, motorbus, autobus, etc.) is a road vehicle that carries significantly more passengers than an average car or van. It is most commonly used in public transport, but is also in use for cha ...
or prescribed sub-bus. An offline unit provides electrical isolation between the primary power source and the critical technical load whereas an online unit does not. A Class A power source is a primary power source, i.e., a source that assures an essentially continuous supply of power. Types of auxiliary power services include Class B, a standby power
plant Plants are predominantly photosynthetic eukaryotes of the kingdom Plantae. Historically, the plant kingdom encompassed all living things that were not animals, and included algae and fungi; however, all current definitions of Plantae exclud ...
to cover extended outages of the order of days; Class C, a 10-to-60-second quick-start unit to cover short-term outages of the order of hours; and Class D, an uninterruptible non-break unit using stored energy to provide continuous power within specified voltage and
frequency Frequency is the number of occurrences of a repeating event per unit of time. It is also occasionally referred to as ''temporal frequency'' for clarity, and is distinct from ''angular frequency''. Frequency is measured in hertz (Hz) which is eq ...
tolerances.


History


Uses/Implementations

Many uses and implementations of auxiliary power are experimented with to increase its efficiency. One such experimentation was to find a better way to operate a
diesel engine The diesel engine, named after Rudolf Diesel, is an internal combustion engine in which ignition of the fuel is caused by the elevated temperature of the air in the cylinder due to mechanical compression; thus, the diesel engine is a so-call ...
with
fuel cell A fuel cell is an electrochemical cell that converts the chemical energy of a fuel (often hydrogen) and an oxidizing agent (often oxygen) into electricity through a pair of redox reactions. Fuel cells are different from most batteries in requ ...
based auxiliary power units.  The method of which is to separate
hydrogen Hydrogen is the chemical element with the symbol H and atomic number 1. Hydrogen is the lightest element. At standard conditions hydrogen is a gas of diatomic molecules having the formula . It is colorless, odorless, tasteless, non-toxic, an ...
-rich gas from the
diesel fuel Diesel fuel , also called diesel oil, is any liquid fuel specifically designed for use in a diesel engine, a type of internal combustion engine in which fuel ignition takes place without a spark as a result of compression of the inlet air and t ...
to generate
electricity Electricity is the set of physical phenomena associated with the presence and motion of matter that has a property of electric charge. Electricity is related to magnetism, both being part of the phenomenon of electromagnetism, as described ...
separately in an auxiliary power unit.Samsun, Krekel, Pasel, Prawitz, Peters, & Stolten. (2017). A diesel fuel processor for fuel-cell-based auxiliary power unit applications. ''Journal of Power Sources,'' ''355'', 44-52.  With this process, an effective reduction in emissions can be achieved by lowering the consumed volume of gas per hour. However, upon  power demands reaching 60% a sharp decrease in performance occurs, which can be solved by using a diesel or kerosine fuel with a maximum CO concentration of 1.5%. There are a variety of other implementations of auxiliary power units in energy systems. This explains for how a significant portion of emissions come from commercial vehicles.  Diesel engines operating within densely populated areas, running within an ineffective range in order to power their auxiliary systems, such as
refrigeration The term refrigeration refers to the process of removing heat from an enclosed space or substance for the purpose of lowering the temperature.International Dictionary of Refrigeration, http://dictionary.iifiir.org/search.phpASHRAE Terminology, ht ...
, are contributors to a large portion of the emissions from automobiles.Matulic, N., Radica, G., Barbir, F., & Nizetic, S. (2018). Commercial vehicle auxiliary loads powered by PEM fuel cell. ''International Journal of Hydrogen Energy.'' doi: 10.1016/j.ijhydene.2018.12.121  Using a model with a diesel powered four-stroke engine on a truck with 100% load capacity driving a combination of typical urban and city road cycles, emissions and auxiliary power demand were recorded. Then by using the calculated auxiliary power demand, a source was developed to support the demand for the auxiliary systems in the form of a PEM fuel cell.  The end product of the PEM fuel cell was able to support the auxiliary systems of the truck using a maximum of 5 kW of power. This input was able to sustain the cooling chamber, cabin
air-conditioning Air conditioning, often abbreviated as A/C or AC, is the process of removing heat from an enclosed space to achieve a more comfortable interior environment (sometimes referred to as 'comfort cooling') and in some cases also strictly controlling ...
, radio unit, etc. The introduction of this fuel cell also contributed to a 9% reduction in diesel fuel consumption and 9.6% reduction in emissions.


Legal Requirements for Industries

The United States Environmental Protection Agency has set out rules and guidelines for how auxiliary and supplemental power sources (ASPS) that provide secondary power to wastewater treatment plants in case of a blackout.  ASPS should be able to supply enough power to run the plant effectively, and be available for start-up in a short period of time in case of emergency.(2006). Auxiliary and supplementary power fact sheet: viable sources. ''United States Environmental Protection Agency.'' Types of ASPS necessary for adequate power generation include: internal combustion engines, microturbines,
solar cell A solar cell, or photovoltaic cell, is an electronic device that converts the energy of light directly into electricity by the photovoltaic effect, which is a physical and chemical phenomenon.
s,
fuel cell A fuel cell is an electrochemical cell that converts the chemical energy of a fuel (often hydrogen) and an oxidizing agent (often oxygen) into electricity through a pair of redox reactions. Fuel cells are different from most batteries in requ ...
s, and
wind turbine A wind turbine is a device that converts the kinetic energy of wind into electrical energy. Hundreds of thousands of large turbines, in installations known as wind farms, now generate over 650 gigawatts of power, with 60 GW added each year. ...
s.  ASPS technology is required to be reliable enough to start up quickly, and run for extended periods of time, (i.e. 48 hours or more) with sufficient fuel.


Efficiency

As previously affirmed, auxiliary power units are commonly used to improve the efficiency of electrical system. The use of auxiliary power units for range extended electric automobiles has been shown to improve the control of energy flow and distribution throughout the system, improving its overall efficiency.Zhang, H., Yang, Q., Song, J., & Fu, L. (2017). Study and realization on power energy distribution control for auxiliary power unit. ''Energy Procedia,'' 5. doi: 10.1016/j.egypro.2017.03.748 For closed systems with extreme power consumption such as tankers and other vessels at sea, the use and quality of auxiliary power systems have a great impact on the efficiency of the overall system.  The different uses of auxiliary power for an array of ships and ship activities and how these different power schemes change the overall efficiency and/emissions of the ship's system. Studies have indicated that while ships travel between ports within the same bay, total ship exhaust emissions are due to primarily their auxiliary boiler and auxiliary engine power systems, due to the time and speed required to transit the port waters with the large berth of the vessel.Goldsworthy, B. & Goldsworthy, L. (2018). Assigning Machinery power values for estimating ship exhaust emissions: comparison of auxiliary power schemes. ''Science of the Total Environment,'' 963-977. doi: 10.1016/j.scitotenv.2018.12.014  Findings also lead to the conclusion that the power output capabilities of auxiliary engines at a certain point do not increase with the size of the vessel, or the vessel's installed main engine power. There are a great many factors such as machinery variables, power schemes, and size and power of vessels, that there are too many factors to take into account in order to portray an accurate representation of the ratio between main power and auxiliary power output. More surveys and studies should be done in order to achieve this more accurate result.


See also

*
distributed generation Distributed generation, also distributed energy, on-site generation (OSG), or district/decentralized energy, is electrical generation and storage performed by a variety of small, grid-connected or distribution system-connected devices referred to ...


References

{{Reflist *
Federal Standard 1037C Federal Standard 1037C, titled Telecommunications: Glossary of Telecommunication Terms, is a United States Federal Standard issued by the General Services Administration pursuant to the Federal Property and Administrative Services Act of 1949, a ...
and MIL-STD-180f. Electric power