Atkinson Resistance
   HOME

TheInfoList



OR:

Atkinson resistance is commonly used in
mine ventilation Underground mine ventilation provides a flow of air to the underground workings of a mine of sufficient volume to dilute and remove dust and noxious gases (typically NOx, SO2, methane, CO2 and CO) and to regulate temperature. The source of ...
to characterise the resistance to airflow of a duct of irregular size and shape, such as a mine roadway. It has the symbol R and is used in the square law for pressure drop, :\Delta P = \fracRQ^2 where (in
English units English units are the units of measurement used in England up to 1826 (when they were replaced by Imperial units), which evolved as a combination of the Anglo-Saxon and Roman systems of units. Various standards have applied to English units at ...
) * \Delta P is pressure drop (pounds per square foot), * \rho_ is the air density in the duct (pounds per cubic foot), * \rho_ is the standard air density (0.075 pound per cubic foot), * R is the resistance (atkinsons), * Q is the rate of flow of air (thousands of cubic feet per second). One atkinson is defined as the resistance of an airway which, when air flows along it at a rate of 1,000 cubic feet per second, causes a pressure drop of one pound-force per square foot. The unit is named after J J Atkinson, who published one of the earliest comprehensive mathematical treatments of mine ventilation. Atkinson based his expressions for airflow resistance on the more general work of Chézy and Darcy who defined frictional pressure drop as :\Delta P = \frac\rho f L \fracv^2 where * \Delta P is pressure drop, * \rho is the density of the fluid in question (water, air, oil etc.), * f is the
Fanning friction factor The Fanning friction factor, named after John Thomas Fanning, is a dimensionless number used as a local parameter in continuum mechanics calculations. It is defined as the ratio between the local shear stress and the local flow kinetic energy d ...
, * L is the length of the duct, * S is the perimeter of the duct, * A is the area of the duct, * v is the velocity of the fluid. The practicalities of mine ventilation led Atkinson to group some of these variables into one all-encompassing term: * Area and perimeter were incorporated because mine airways are of irregular shape, and both vary along the length of an airway. * velocity v was replaced by the ratio of flowrate to area (Q/A) because variations in area cause variations in velocity. Area was then incorporated into the denominator of the Atkinson resistance term. * Length of the airway was incorporated. This may have been a step too far, as most of his successors chose to give values of Atkinson resistance in terms of atkinsons per unit length (often 100 or 1,000 yards). * The term 1/2\rho was incorporated, which later authors definitely considered a step too far (e.g. McPherson, 1988). In Atkinson's time not only were all British mines shallow enough that the density of air could be considered constant, but fan design was primitive enough that variations in density would make no measurable difference to the amount of motive power required. Atkinson did not foresee that his methods would be applied several miles underground, where air is 30–50% denser than it is at the surface. Density variations of this magnitude can alter the power consumption of colliery ventilation fans by hundreds of
kilowatts The watt (symbol: W) is the unit of power or radiant flux in the International System of Units (SI), equal to 1 joule per second or 1 kg⋅m2⋅s−3. It is used to quantify the rate of energy transfer. The watt is named after James W ...
. The resulting term is one that can be easily calculated from the results of two simple measurements: a pressure survey by the gauge and tube method and a flowrate survey with a counting anemometer. This is a major strength and is the reason why Atkinson resistance remains in use today. A complete definition of Atkinson resistance R in more common fluid flow terms is as follows: :R = \frac\rho \frac \equiv \frac\rho\frac \equiv \frac\rho\frac \equiv \frac\rho\frac in which * R_ is
hydraulic radius The Manning formula or Manning's equation is an empirical formula estimating the average velocity of a liquid flowing in a conduit that does not completely enclose the liquid, i.e., open channel flow. However, this equation is also used for calculat ...
, * D_ is
hydraulic diameter The hydraulic diameter, , is a commonly used term when handling flow in non-circular tubes and channels. Using this term, one can calculate many things in the same way as for a round tube. When the cross-section is uniform along the tube or channel ...
and * \lambda is
Darcy friction factor Darcy, Darci or Darcey may refer to: Science * Darcy's law, which describes the flow of a fluid through porous material * Darcy (unit), a unit of permeability of fluids in porous material * Darcy friction factor in the field of fluid mechanics ...
in addition to the terms defined above. Atkinson also defined a friction factor (
Atkinson friction factor Atkinson friction factor is a measure of the resistance to airflow of a duct. It is widely used in the mine ventilation industry but is rarely referred to outside of it. Atkinson friction factor is represented by the symbol k and has the same uni ...
) used for airways of fixed section such as shafts. It accounts for
Fanning friction factor The Fanning friction factor, named after John Thomas Fanning, is a dimensionless number used as a local parameter in continuum mechanics calculations. It is defined as the ratio between the local shear stress and the local flow kinetic energy d ...
, density and the constant 1/2 and relates to Atkinson resistance by :R = \frac * where k is Atkinson friction factor and the other terms are as defined above. Despite its weakness with regards to density changes, the use of Atkinson resistance is so widespread in the mining industry that a corresponding term in
metric units Metric units are units based on the metre, gram or second and decimal (power of ten) multiples or sub-multiples of these. The most widely used examples are the units of the International System of Units (SI). By extension they include units of e ...
has also been defined. It, too, is termed the atkinson resistance but the unit was given the name gaul (for reasons unknown). The earliest known use of the name is a 1971 British Coal memorandum on metrication, VB/CIRC/71(26). One gaul is defined as the resistance of an airway which, when air (of density 1.2 kg/m3) flows along it at a rate of one cubic metre per second, causes a pressure drop of one pascal. The gaul has units of N·s2/m8, or alternatively Pa·s2/m6. It uses the same basic equation as its Imperial counterpart, but with slightly different
dimensions In physics and mathematics, the dimension of a mathematical space (or object) is informally defined as the minimum number of coordinates needed to specify any point within it. Thus, a line has a dimension of one (1D) because only one coordin ...
: :\Delta P = \fracRQ^2 where * \Delta P is pressure drop (pascals), * \rho_ is the air density in the air duct (kilograms per cubic metre), * \rho_ is the standard air density (1.2 kilograms per cubic metre), * R is the resistance of the air path (gauls), * Q is the rate of flow of air (cubic metres per second). The metric and Imperial resistances are related by :1 \mbox = 1 \mbox \times \frac \equiv 1 \times \frac \equiv 16.747 \mbox where g is the standard acceleration of gravity (metres per second squared). The metric equivalent is now more widely used than the original Imperial definition. Most suppliers quote resistances of flexible temporary ventilation ducts in gauls/100 m and in most mine ventilation software programs, branch resistances are given in gauls.


References

* National Coal Board Information Bulletin 55/153, ''Planning the Ventilation of New and Reorganised Collieries'', 1955 * National Coal Board Mining Dept, ''Coal mine ventilation: a handbook for colliery ventilation engineers'', NCB 1979
McPherson, M J, ''An analysis of the resistance and airflow characteristics of mine shafts,'' Proceedings of the 4th International Mine Ventilation Congress, Brisbane, 1988
* National Coal Board Memorandum VB/CIRC/71(26), from DER Lloyd to All Area Ventilation Engineers: "Metrication - Airway Resistance", 5 May 1971


Further reading

* Atkinson, J J, ''Gases met with in Coal Mines, and the general principles of Ventilation'' Transactions of the Manchester Geological Society, Vol. III, p. 218, 1862
McPherson, M J, ''Subsurface Ventilation Engineering'', 2nd edition
(ISBN of 1st edition - Chapman & Hall 1993 - is {{ISBN, 0-412-35300-8) Fluid dynamics Mine ventilation