Air Cleaners
   HOME

TheInfoList



OR:

An air purifier or air cleaner is a device which removes contaminants from the air in a room to improve indoor air quality. These devices are commonly marketed as being beneficial to allergy sufferers and asthmatics, and at reducing or eliminating second-hand tobacco smoke. The commercially graded air purifiers are manufactured as either small stand-alone units or larger units that can be affixed to an air handler unit (AHU) or to an
HVAC Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HV ...
unit found in the medical, industrial, and commercial industries. Air purifiers may also be used in industry to remove impurities from air before processing. Pressure swing adsorbers or other adsorption techniques are typically used for this.


History

In 1830, a patent was awarded to Charles Anthony Deane for a device comprising a copper helmet with an attached flexible collar and garment. A long leather hose attached to the rear of the helmet was to be used to supply air, the original concept being that it would be pumped using a double bellows. A short pipe allowed breathed air to escape. The garment was to be constructed from leather or airtight cloth, secured by straps. In the 1860s,
John Stenhouse John Stenhouse FRS FRSE FIC FCS (21 October 1809 – 31 December 1880) was a Scottish chemist. In 1854, he invented one of the first practical respirators. He was a co-founder of the Chemical Society in 1841. Life John Stenhouse was born ...
filed two patents applying the absorbent properties of wood charcoal to air purification (patents 19 July 1860 and 21 May 1867), thereby creating the first practical respirator. In 1871, the physicist
John Tyndall John Tyndall FRS (; 2 August 1820 – 4 December 1893) was a prominent 19th-century Irish physicist. His scientific fame arose in the 1850s from his study of diamagnetism. Later he made discoveries in the realms of infrared radiation and the p ...
wrote about his invention, a fireman's respirator, as a result of a combination of protective features of the Stenhouse's respirator and other breathing devices. This invention was later described in 1875. In the 1950s, HEPA filters were commercialized as highly efficient air filters, after being put to use in the 1940s in the United States' Manhattan Project to control airborne radioactive contaminants. The first residential HEPA filter was reportedly sold in 1963 by brothers Manfred and Klaus Hammes in Germany, who created the Incen Air Corporation which was the precursor to the IQAir corporation.


Use and benefits

Dust,
pollen Pollen is a powdery substance produced by seed plants. It consists of pollen grains (highly reduced microgametophytes), which produce male gametes (sperm cells). Pollen grains have a hard coat made of sporopollenin that protects the gametophyt ...
, pet dander, mold
spore In biology, a spore is a unit of sexual or asexual reproduction that may be adapted for dispersal and for survival, often for extended periods of time, in unfavourable conditions. Spores form part of the life cycles of many plants, algae, f ...
s, and
dust mite House dust mites (HDM, or simply dust mites) are various species of acariform mites belonging to the family Pyroglyphidae that are found in association with dust in dwellings. They are known for causing allergies. Biology Species The curren ...
feces Feces ( or faeces), known colloquially and in slang as poo and poop, are the solid or semi-solid remains of food that was not digested in the small intestine, and has been broken down by bacteria in the large intestine. Feces contain a relati ...
can act as
allergens An allergen is a type of antigen that produces an abnormally vigorous immune response in which the immune system fights off a perceived threat that would otherwise be harmless to the body. Such reactions are called allergies. In technical terms ...
, triggering allergies in sensitive people. Smoke particles and volatile organic compounds (VOCs) can pose a risk to health. Exposure to various components such as VOCs increases the likelihood of experiencing symptoms of
sick building syndrome Sick building syndrome (SBS) is an unsubstantiated diagnosis where health problems are attributed to buildings. The cause of the health problems are unknown. Symptoms attributed to SBS may or may not be a direct result of inadequate cleaning or ...
.


COVID-19

Joseph Allen, director of the Healthy Buildings program at Harvard's School of Public Health, recommends that school classrooms use an air purifier with a HEPA filter as a way to reduce transmission of COVID-19 virus, saying "Portables with a high-efficiency HEPA filter and sized for the appropriate room can capture 99.97 percent of airborne particles." One fluid dynamic modelling study from January 2021 suggests that operating air purifiers or air ventilation systems in confined spaces, such as an elevator, during their occupancy by multiple people leads to air circulation effects that could, theoretically, enhance viral transmission. However, real-life testing of portable HEPA/UV air filters in COVID-19 wards in hospital demonstrated complete elimination of air-borne SARS-CoV-2. Interestingly this report also showed a significant reduction in other bacteria, fungal and viral
bioaerosol Bioaerosols (short for biological aerosols) are a subcategory of particles released from terrestrial and marine ecosystems into the atmosphere. They consist of both living and non-living components, such as fungi, pollen, bacteria and viruses. Comm ...
, suggesting that portable filters such as this may be able to prevent not only nosocomial spread of COVID-19 but also other hospital-acquired infections.


Purifying techniques

There are two types of air purifying technologies, ''active'' and ''passive''. Active air purifiers release negatively charged ions into the air, causing pollutants to stick to surfaces, while passive air purification units use air filters to remove pollutants. Passive purifiers are more efficient since all the dust and
particulate matter Particulates – also known as atmospheric aerosol particles, atmospheric particulate matter, particulate matter (PM) or suspended particulate matter (SPM) – are microscopic particles of solid or liquid matter suspended in the air. The ter ...
is permanently removed from the air and collected in the filters. Several different processes of varying effectiveness can be used to purify air. As of 2005, the most common methods were high-efficiency particulate air (HEPA) filters and ultraviolet germicidal irradiation (UVGI).


Filtration

Air filter purification traps airborne particles by size exclusion. Air is forced through a filter and particles are physically captured by the filter. Various filters exist notably including: * High-efficiency particulate arrestance ( HEPA) filters remove at least 99.97% of 0.3-micrometer particles and are usually more effective at removing larger and smaller particles. HEPA purifiers, which filter all the air going into a clean room, must be arranged so that no air bypasses the HEPA filter. In dusty environments, a HEPA filter may follow an easily cleaned conventional filter (prefilter) which removes coarser impurities so that the HEPA filter needs cleaning or replacing less frequently. HEPA filters do not generate ozone or harmful byproducts in the course of operation. * Filter HVAC at MERV 14 or above are rated to remove airborne particles of 0.3 micrometers or larger. A high-efficiency MERV 14 filter has a capture rate of at least 75% for particles between 0.3 and 1.0 micrometers. Although the capture rate of a MERV filter is lower than that of a HEPA filter, a central air system can move significantly more air in the same period of time. Using a high-grade MERV filter can be more effective than using a high-powered HEPA machine at a fraction of the initial capital expenditure. Unfortunately, most furnace filters are slid in place without an airtight seal, which allows air to pass around the filters. This problem is worse for the higher-efficiency MERV filters because of the increase in air resistance. Higher-efficiency MERV filters are usually denser and increase air resistance in the central system, requiring a greater air pressure drop and consequently increasing energy costs. * There is ongoing research to enable viable and effective
biocide A biocide is defined in the European legislation as a chemical substance or microorganism intended to destroy, deter, render harmless, or exert a controlling effect on any harmful organism. The US Environmental Protection Agency (EPA) uses a slig ...
treated air filters (i.e. air filters coated with antimicrobial agents) for preventing the spread of airborne pathogens.


Other methods

* Ultraviolet germicidal irradiation - UVGI can be used to sterilize air that passes UV lamps via forced air. Air purification UVGI systems can be freestanding units with shielded UV lamps that use a fan to force air past the UV light. Other systems are installed in forced air systems so that the circulation for the premises moves micro-organisms past the lamps. Key to this form of sterilization is the placement of the UV lamps and a good filtration system to remove the dead micro-organisms. For example, forced air systems by design impede line-of-sight, thus creating areas of the environment that will be shaded from the UV light. However, a UV lamp placed at the coils and drain pan of the cooling system will keep micro-organisms from forming in these naturally damp places. The most effective method for treating the air rather than the coils is in-line duct systems, these systems are placed in the center of the duct and parallel to the airflow. *
Activated carbon Activated carbon, also called activated charcoal, is a form of carbon commonly used to filter contaminants from water and air, among many other uses. It is processed (activated) to have small, low-volume pores that increase the surface area avail ...
is a porous material that can
adsorb Adsorption is the adhesion of atoms, ions or molecules from a gas, liquid or dissolved solid to a surface. This process creates a film of the ''adsorbate'' on the surface of the ''adsorbent''. This process differs from absorption, in which a fl ...
volatile chemicals on a molecular basis, but does not remove larger particles. The adsorption process when using activated carbon must reach equilibrium thus it may be difficult to completely remove contaminants. Activated carbon is merely a process of changing contaminants from a gaseous phase to a solid phase, when aggravated or disturbed contaminants can be regenerated in indoor air sources. Activated carbon can be used at room temperature and has a long history of commercial use. It is normally used in conjunction with other filter technology, especially with HEPA. Other materials can also absorb chemicals but at a higher cost. *Polarized-media electronic air cleaners use active electronically enhanced media to combine elements of both electronic air cleaners and passive mechanical filters. Most polarized-media electronic air cleaners use safe 24-volt DC voltage to establish the polarizing electric field. Most airborne particles have a charge and many are even bi-polar. As airborne particles pass through the electric field the polarized field re-orients the particle to adhere to a disposable fiber media pad. Ultra-fine particles (UFPs) that are not collected on their initial pass through the media pad are polarized and agglomerate to other particles, odor and VOC molecules and are collected on subsequent passes. The efficiency of polarized-media electronic air cleaners increases as they load, providing high-efficiency filtration, with air resistance typically equal to or less than passive filters. Polarized-media technology is non-ionizing, which means no ozone is produced. *
Photocatalytic oxidation In chemistry, photocatalysis is the acceleration of a photoreaction in the presence of a catalyst. In catalyzed photolysis, light is absorbed by an adsorbed substrate. In photogenerated catalysis, the photocatalytic activity depends on the abili ...
(PCO) is an emerging technology in the HVAC industry. In addition to the prospect of Indoor Air Quality (IAQ) benefits, it has the added potential for limiting the introduction of unconditioned air to the building space, thereby presenting an opportunity to achieve energy savings over previous prescriptive designs. As of May 2009 there was no more disputable concern raised by the Lawrence Berkeley National Laboratory data that PCO may significantly increase the amount of formaldehyde in real indoor environments. As with other advanced technologies, sound engineering principles and practices should be employed by the HVAC designer to ensure proper application of the technology.
Photocatalytic In chemistry, photocatalysis is the acceleration of a photoreaction in the presence of a catalyst. In catalyzed photolysis, light is absorbed by an adsorbed substrate. In photogenerated catalysis, the photocatalytic activity depends on the abi ...
oxidation systems are able to completely oxidize and degrade organic contaminants. For example, Volatile Organic Compounds found low concentrations within a few hundred ppmv or less are the most likely to be completely oxidized.(PCO) uses short-wave ultraviolet light (UVC), commonly used for sterilization, to energize the catalyst (usually titanium dioxide (TiO2)) and oxidize bacteria and viruses. PCO in-duct units can be mounted to an existing forced-air
HVAC Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HV ...
system. PCO is not a filtering technology, as it does not trap or remove particles. It is sometimes coupled with other filtering technologies for air purification. UV sterilization bulbs must be replaced about once a year; manufacturers may require periodic replacement as a condition of warranty. Photocatalytic Oxidation systems often have high commercial costs. :A related technology relevant to air purification is photoelectrochemical oxidation (PECO) Photoelectrochemical oxidation. While technically a type of PCO, PECO involves electrochemical interactions among the catalyst material and reactive species (e.g., through emplacement of cathodic materials) to improve quantum efficiency; in this way, it is possible to use lower energy UVA radiation as the light source and yet achieve improved effectiveness. * Ionizer purifiers use charged electrical surfaces or needles to generate electrically charged air or gas ions. These ions attach to airborne particles which are then electrostatically attracted to a charged collector plate. This mechanism produces trace amounts of ozone and other oxidants as by-products. Most ionizers produce less than 0.05 ppm of ozone, an industrial safety standard. There are two major subdivisions: the fanless ionizer and fan-based ionizer. Fanless ionizers are noiseless and use little power, but are less efficient at air purification. Fan-based ionizers clean and distribute air much faster. Permanently mounted home and industrial ionizer purifiers are called electrostatic precipitators. *Plasma air purifiers are a form of ionizing air purifier. Instead of precipitating particles on a plate, they are primarily intended to destroy volatile organic compounds, bacteria, and viruses by chemical reactions with generated ions. While promising in laboratory conditions, their usefulness and safety has not been established in air purification. *Far- UVC air purification systems (under development). *
Immobilized cell technology Immobilized cell technology is a method of air filtration and purification that uses Immobilized whole cell, whole cell immobilization. It is a process whereby microfine particulate matter is removed from the air by attracting charged particulates ...
removes microfine particulate matter from the air by attracting charged particulates to a bio-reactive mass, or bioreactor, which enzymatically renders them inert. * Ozone generators are designed to produce ozone and are sometimes sold as whole-house air cleaners. Unlike ionizers, ozone generators are intended to produce significant amounts of ozone, a strong oxidant gas which can oxidize many other chemicals. The only safe use of ozone generators is in unoccupied rooms, utilising "shock treatment" commercial ozone generators that produce over 3000 mg of ozone per hour. Restoration contractors use these types of ozone generators to remove smoke odors after fire damage, musty smells after flooding, mold (including
toxic mold Mold health issues refer to the harmful health effects of molds ("moulds" in British English) and their mycotoxins. However, recent research has shown these adverse health effects are caused not exclusively by molds, but also other microbial agen ...
s), and the stench caused by decaying flesh which cannot be removed by bleach or anything else except for ozone. However, it is not healthy to breathe ozone gas, and one should use extreme caution when buying a room air purifier that also produces ozone. * Titanium dioxide (TiO2) technology -
nanoparticles A nanoparticle or ultrafine particle is usually defined as a particle of matter that is between 1 and 100 nanometres (nm) in diameter. The term is sometimes used for larger particles, up to 500 nm, or fibers and tubes that are less than 1 ...
of TiO2, together with calcium carbonate to neutralize any
acid In computer science, ACID ( atomicity, consistency, isolation, durability) is a set of properties of database transactions intended to guarantee data validity despite errors, power failures, and other mishaps. In the context of databases, a sequ ...
ic gasses that may be adsorbed, is mixed into slightly porous paint. Photocatalysis initiates the decomposition of airborne contaminants at the surface. *Thermodynamic sterilization (TSS) - This technology uses heat sterilization via a ceramic core with microcapillaries, which are heated to . It is claimed that 99.9% of microbiological particles - bacteria, viruses, dust mite allergens, mold and fungus spores - are incinerated. The air passes through the ceramic core by the natural process of air convection, and is then cooled using heat transfer plates and released. TSS is not a filtering technology, as it does not trap or remove particles. TSS is claimed not to emit harmful by-products (although the byproducts of partial thermal decomposition are not addressed) and also reduces the concentration of ozone in the atmosphere. *Reactive Oxygen Species (ROS) Technology also known as "ROS Purifier" - There are 7 airborne ROS. Some are short-lived and some are long-lived. The five short-lived ones are going to be hydroxyl radical, Singlet Oxygen (dioxidene), Superoxide, Atomic Oxygen, Peroxynitrite (peroxynitrite). The two long-lived ROS ones are Hydrogen Peroxide – Gas Phased, and Ozone. Due to the long-lived Hydrogen Peroxide (gas phased) and with low levels of Ozone (30ppb - 50 ppb) It is very effective in killing pathogens that include mold, bacteria, viruses, and germs in the air and on surfaces and provide odor control. Unlike Ozone generators that produce a high amount of ozone that is used as "shock treatment" is only effective in empty rooms without people present whereas ROS (Reactive Oxygen Species) purifiers can be effective safely 24/7 while people are present when ozone is (30ppb - 50 ppb). ROS (Reactive Oxygen Species) has very effective long-distance surface treatment due to its output of ozone (30ppb - 50ppb) and Hydrogen Peroxide it has, unlike Titanium dioxide that produces 2 ROS which are Hydroxyl radicals and superoxide that are a very short distance on surface treatment.


Consumer concerns

Other aspects of air cleaners are hazardous gaseous by-products, noise level, frequency of filter replacement, electrical consumption, and visual appeal. Ozone production is typical for air ionizing purifiers. Although a high concentration of ozone is dangerous, most air ionizers produce low amounts (< 0.05 ppm). The noise level of a purifier can be obtained through a customer service department and is usually reported in
decibel The decibel (symbol: dB) is a relative unit of measurement equal to one tenth of a bel (B). It expresses the ratio of two values of a power or root-power quantity on a logarithmic scale. Two signals whose levels differ by one decibel have a po ...
s (dB). The noise levels for most purifiers are low compared to many other home appliances. Frequency of filter replacement and electrical consumption are the major operation costs for any purifier. There are many types of filters; some can be cleaned by water, by hand or by vacuum cleaner, while others need to be replaced every few months or years. In the United States, some purifiers are certified as Energy Star and are energy efficient. HEPA technology is used in portable air purifiers as it removes common airborne allergens. The US Department of Energy has requirements manufacturers must pass to meet HEPA requirements. The HEPA specification requires removal of at least 99.97% of 0.3 micrometers airborne pollutants. Products that claim to be "HEPA-type", "HEPA-like", or "99% HEPA" do not satisfy these requirements and may not have been tested in independent laboratories. Air purifiers may be rated on a variety of factors, including Clean Air Delivery Rate (which determines how well air has been purified); efficient area coverage; air changes per hour; energy usage; and the cost of the replacement filters. Two other important factors to consider are the length that the filters are expected to last (measured in months or years) and the noise produced (measured in
decibel The decibel (symbol: dB) is a relative unit of measurement equal to one tenth of a bel (B). It expresses the ratio of two values of a power or root-power quantity on a logarithmic scale. Two signals whose levels differ by one decibel have a po ...
s) by the various settings that the purifier runs on. This information is available from most manufacturers.


Potential ozone hazards

As with other health-related appliances, there is controversy surrounding the claims of certain companies, especially involving ionic air purifiers. Many air purifiers generate some ozone, an energetic
allotrope Allotropy or allotropism () is the property of some chemical elements to exist in two or more different forms, in the same physical state, known as allotropes of the elements. Allotropes are different structural modifications of an element: the ...
of three oxygen atoms, and in the presence of humidity, small amounts of NOx. Because of the nature of the ionization process, ionic air purifiers tend to generate the most ozone. This is a serious concern because ozone is a
criteria air pollutant The U.S. National Ambient Air Quality Standards (NAAQS, pronounced ) are limits on atmospheric concentration of six pollutants that cause smog, acid rain, and other health hazards. Established by the United States Environmental Protection Agenc ...
regulated by health-related US federal and state standards. In a controlled experiment, in many cases, ozone concentrations were well in excess of public and/or industrial safety levels established by US Environmental Protection Agency, particularly in poorly ventilated rooms. Ozone can damage the lungs, causing chest pain, coughing, shortness of breath and throat irritation. It can also worsen chronic respiratory diseases such as asthma and compromise the ability of the body to fight respiratory infections—even in healthy people. People who have asthma and allergy are most prone to the adverse effects of high levels of ozone. For example, increasing ozone concentrations to unsafe levels can increase the risk of asthma attacks. Due to the below average performance and potential health risks,
Consumer Reports Consumer Reports (CR), formerly Consumers Union (CU), is an American nonprofit consumer organization dedicated to independent product testing, investigative journalism, consumer-oriented research, public education, and consumer advocacy. Founded ...
has advised against using ozone producing air purifiers. IQAir, the educational partner of the American Lung Association, has been a leading industry voice against ozone-producing air cleaning technology. Ozone generators used for shock treatments (unoccupied rooms) which are needed by smoke, mold, and odor remediation contractors as well as crime scene cleanup companies to oxidize and permanently remove smoke, mold, and odor damage are considered a valuable and effective tool when used correctly for commercial and industrial purposes. However, there is a growing body of evidence that these machines can produce undesirable by-products. In September 2007, the California Air Resources Board announced a ban of indoor air cleaning devices which produce ozone above a legal limit. This law, which took effect in 2010, requires testing and certification of all types of indoor air cleaning devices to verify that they do not emit excessive ozone.


Industry and markets

As of 2015, the United States residential air purifier total addressable market was estimated at around $2 billion per year.


See also

* Air filter * Air ioniser *
Air sanitizer An air sanitizer is a sanitizer that acts on airborne microbiological organisms or microorganisms. In the United States, a sanitizer is a disinfectant that is intended to disinfect or sanitize, reducing or mitigating growth or development of microb ...
* Electrostatic precipitator * HEPA * PCO (Photocatalytic oxidation) *
PECO PECO is a UK-based manufacturer of model railway accessories, especially trackwork, based at Pecorama, Beer in South Devon, England. PECO is the collective name for the Pritchard Patent Product Company Ltd, Peco Publications and Publicity L ...
(Photoelectrochemical oxidation) * Nose filter * NASA Clean Air Study * Ozone generator *
Smog tower Smog towers or smog free towers (see below for other names) are structures designed as large-scale air purifiers to reduce air pollution particles (smog). This approach to the problem of urban air pollution involves air filtration, and removal o ...
*
Scrubber Scrubber systems (e.g. chemical scrubbers, gas scrubbers) are a diverse group of air pollution control devices that can be used to remove some particulates and/or gases from industrial exhaust streams. An early application of a carbon dioxide scr ...
*
Corsi–Rosenthal Box The Corsi–Rosenthal Box, also called Corsi–Rosenthal Cube and Comparetto Cube, is a design for a do-it-yourself air purifier that can be built comparatively inexpensively. It was designed during the COVID-19 pandemic, with the goal of reducin ...


References


External links


CADR.org
Information on Clean Air Delivery Rate by AHAM
DOE HEPA Filter Standards
HEPA filter specifications for DOE contractors
Potera, C. (2011), Wood-Burning Stoves Get Help from HEPA Filters
US National Institutes of Health The National Institutes of Health, commonly referred to as NIH (with each letter pronounced individually), is the primary agency of the United States government responsible for biomedical and public health research. It was founded in the late ...
{{DEFAULTSORT:Air Purifier Building biology Medical equipment Filters Industrial gases Gas technologies