Twinax
Twinaxial cabling, or "Twinax", is a type of cable similar to coaxial cable, but with two inner conductors instead of one. Due to cost efficiency it is becoming common in modern (2013) very-short-range high-speed differential signaling applications. Legacy applications IBM Historically, Twinax was the cable specified for the IBM 5250 terminals and printers, used with IBM's System/34, System/36, System/38, and IBM AS/400 midrange hosts, and with IBM Power Systems machines running IBM i. The data transmission is half-duplex, balanced transmission, at 1 Mbit/s, on a single shielded, 110 Ω twisted pair. With Twinax seven devices can be addressed, from workstation address 0 to 6. The devices do not have to be sequential. Twinax is a bus topology that requires termination to function properly. Most Twinax T-connectors have an automatic termination feature. For use in buildings wired with Category 3 or higher twisted pair there are baluns that convert Twinax to twisted pair and hubs t ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
Twinax Stecker
Twinaxial cabling, or "Twinax", is a type of cable similar to coaxial cable, but with two inner conductors instead of one. Due to cost efficiency it is becoming common in modern (2013) very-short-range high-speed differential signaling applications. Legacy applications IBM Historically, Twinax was the cable specified for the IBM 5250 terminals and printers, used with IBM's System/34, System/36, System/38, and IBM AS/400 midrange hosts, and with IBM Power Systems machines running IBM i. The data transmission is half-duplex, balanced transmission, at 1 Mbit/s, on a single shielded, 110 Ω twisted pair. With Twinax seven devices can be addressed, from workstation address 0 to 6. The devices do not have to be sequential. Twinax is a bus topology that requires termination to function properly. Most Twinax T-connectors have an automatic termination feature. For use in buildings wired with Category 3 or higher twisted pair there are baluns that convert Twinax to twisted pair and hubs ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
Balun
A balun (from "balanced to unbalanced", originally, but now dated from "balancing unit") is an electrical device that allows balanced and unbalanced lines to be interfaced without disturbing the impedance arrangement of either line. A balun can take many forms and may include devices that also transform impedances but need not do so. Sometimes, in the case of transformer baluns, they use magnetic coupling but need not do so. Common-mode chokes are also used as baluns and work by eliminating, rather than rejecting, common mode signals. Types of balun Classical transformer type In classical transformers, there are two electrically separate windings of wire coils around the transformer's core. The advantage of transformer-type over other types of balun is that the electrically separate windings for input and output allow these baluns to connect circuits whose ground-level voltages are subject to ground loops or are otherwise electrically incompatible; for that reason they ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
IBM 5250
IBM 5250 is a family of block-oriented terminals originally introduced with the IBM System/34 midrange computer systems in 1977. It also connects to the later System/36, System/38, and IBM AS/400 systems, and to IBM Power Systems systems running IBM i. Components 5250 devices can be directly attached to the host or communicate remotely using Synchronous Data Link Control (SDLC) at up to 9600bit/s. Devices can also be clustered or daisy-chained. In 1980 the 5250 system consisted of the following components: * 5251 Display Station. The monochrome text-only display can be either 960 characters, formatted as 12 lines of 80 characters, or 1920 characters as 24 lines of 80 characters. Upper and lower case is standard. Text attributes consist of blink, high intensity, reverse video, non-display, underscore, and a unique ''column separator'' that causes the field to be preceded and followed by a vertical bar. 5251 and 5252 input ''format control'' attributes are optimized for data ent ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
SFP+
Small Form-factor Pluggable connected to a pair of fiber-optic cables Small Form-factor Pluggable (SFP) is a compact, hot-pluggable network interface module format used for both telecommunication and data communications applications. An SFP interface on networking hardware is a modular slot for a media-specific transceiver, such as for a fiber-optic cable or a copper cable. The advantage of using SFPs compared to fixed interfaces (e.g. modular connectors in Ethernet switches) is that individual ports can be equipped with different types of transceiver as required. The form factor and electrical interface are specified by a multi-source agreement (MSA) under the auspices of the Small Form Factor Committee. The SFP replaced the larger gigabit interface converter (GBIC) in most applications, and has been referred to as a Mini-GBIC by some vendors. SFP transceivers exist supporting synchronous optical networking (SONET), Gigabit Ethernet, Fibre Channel, PON, and other communi ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
Coaxial Cable
Coaxial cable, or coax (pronounced ) is a type of electrical cable consisting of an inner conductor surrounded by a concentric conducting shield, with the two separated by a dielectric ( insulating material); many coaxial cables also have a protective outer sheath or jacket. The term ''coaxial'' refers to the inner conductor and the outer shield sharing a geometric axis. Coaxial cable is a type of transmission line, used to carry high-frequency electrical signals with low losses. It is used in such applications as telephone trunk lines, broadband internet networking cables, high-speed computer data busses, cable television signals, and connecting radio transmitters and receivers to their antennas. It differs from other shielded cables because the dimensions of the cable and connectors are controlled to give a precise, constant conductor spacing, which is needed for it to function efficiently as a transmission line. Coaxial cable was used in the first (1858) and followin ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
100 Gbit Ethernet
40 Gigabit Ethernet (40GbE) and 100 Gigabit Ethernet (100GbE) are groups of computer networking technologies for transmitting Ethernet frames at rates of 40 and 100 gigabits per second (Gbit/s), respectively. These technologies offer significantly higher speeds than 10 Gigabit Ethernet. The technology was first defined by the IEEE 802.3ba-2010 standard and later by the 802.3bg-2011, 802.3bj-2014, 802.3bm-2015, and 802.3cd-2018 standards. The standards define numerous port types with different optical and electrical interfaces and different numbers of optical fiber strands per port. Short distances (e.g. 7 m) over twinaxial cable are supported while standards for fiber reach up to 80 km. Standards development On July 18, 2006, a call for interest for a High Speed Study Group (HSSG) to investigate new standards for high speed Ethernet was held at the IEEE 802.3 plenary meeting in San Diego. The first 802.3 HSSG study group meeting was held in September 2006. In June 20 ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
10 Gigabit Ethernet
10 Gigabit Ethernet (10GE, 10GbE, or 10 GigE) is a group of computer networking technologies for transmitting Ethernet frames at a rate of 10 gigabits per second. It was first defined by the IEEE 802.3ae-2002 standard. Unlike previous Ethernet standards, 10 Gigabit Ethernet defines only full-duplex point-to-point links which are generally connected by network switches; shared-medium CSMA/CD operation has not been carried over from the previous generations Ethernet standards so half-duplex operation and repeater hubs do not exist in 10GbE. The 10 Gigabit Ethernet standard encompasses a number of different physical layer (PHY) standards. A networking device, such as a switch or a network interface controller may have different PHY types through pluggable PHY modules, such as those based on SFP+. Like previous versions of Ethernet, 10GbE can use either copper or fiber cabling. Maximum distance over copper cable is 100 meters but because of its bandwidth requirements, higher ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
Coaxial Cable
Coaxial cable, or coax (pronounced ) is a type of electrical cable consisting of an inner conductor surrounded by a concentric conducting shield, with the two separated by a dielectric ( insulating material); many coaxial cables also have a protective outer sheath or jacket. The term ''coaxial'' refers to the inner conductor and the outer shield sharing a geometric axis. Coaxial cable is a type of transmission line, used to carry high-frequency electrical signals with low losses. It is used in such applications as telephone trunk lines, broadband internet networking cables, high-speed computer data busses, cable television signals, and connecting radio transmitters and receivers to their antennas. It differs from other shielded cables because the dimensions of the cable and connectors are controlled to give a precise, constant conductor spacing, which is needed for it to function efficiently as a transmission line. Coaxial cable was used in the first (1858) and followin ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
Triaxial Cable
Triaxial cable, often referred to as triax for short, is a type of electrical cable similar to coaxial cable, but with the addition of an extra layer of insulation and a second conducting sheath. It provides greater bandwidth and rejection of interference than coax, but is more expensive. Applications Television production The most common use of triaxial cable is in television industry as a connecting cable between a camera and its camera control unit (CCU). The outer sheath is commonly used as a protective earth conductor. The core provides both power and signal connections, with the return for the power being provided through the inner screen. Through frequency-division multiplexing, the camera can send audio and video signals along the triax while the CCU can send camera control information, such as exposure settings, intercom, return audio and video (usually that of the program), and tally (a signal alerting the operator that their camera is on the air). Venues that host tele ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
System/36
The IBM System/36 (often abbreviated as S/36) was a midrange computer marketed by IBM from 1983 to 2000 - a multi-user, multi-tasking successor to the System/34. Like the System/34 and the older System/32, the System/36 was primarily programmed in the RPG II language. One of the machine's optional features was an off-line storage mechanism (on the 5360 model) that utilized "magazines" – boxes of 8-inch floppies that the machine could load and eject in a nonsequential fashion. The System/36 also had many mainframe features such as programmable job queues and scheduling priority levels. While these systems were similar to other manufacturer's minicomputers, IBM themselves described the System/32, System/34 and System/36 as "small systems" and later as midrange computers along with the System/38 and succeeding IBM AS/400 range. The AS/400 series and IBM Power Systems running IBM i can run System/36 code in the System/36 Environment, although the code needs to be recompiled ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
IBM I
IBM i (the ''i'' standing for ''integrated'') is an operating system developed by IBM for IBM Power Systems. It was originally released in 1988 as OS/400, as the sole operating system of the IBM AS/400 line of systems. It was renamed to i5/OS in 2004, before being renamed a second time to IBM i in 2008. It is an evolution of the System/38 CPF operating system, with compatibility layers for System/36 SSP and AIX applications. It inherits a number of distinctive features from the System/38 platform, including the Machine Interface, the implementation of object-based addressing on top of a single-level store, and the tight integration of a relational database into the operating system. History Origin OS/400 was developed alongside the AS/400 hardware platform beginning in December 1985. Development began in the aftermath of the failure of the Fort Knox project, which left IBM without a competitive midrange system. During the Fort Knox project, a skunkworks project was started ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |
|
Category 7 Cable
International standard ISO/IEC 11801 ''Information technology — Generic cabling for customer premises'' specifies general-purpose telecommunication cabling systems (structured cabling) that are suitable for a wide range of applications (analog and ISDN telephony, various data communication standards, building control systems, factory automation). It is published by ISO/IEC JTC 1/ SC 25/WG 3 of the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC). It covers both balanced copper cabling and optical fibre cabling. The standard was designed for use within commercial premises that may consist of either a single building or of multiple buildings on a campus. It was optimized for premises that span up to 3 km, up to 1 km2 office space, with between 50 and 50,000 persons, but can also be applied for installations outside this range. A major revision was released in November 2017, unifying requirements for commercial, ... [...More Info...]       [...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]   |