Remote Terminal Unit
   HOME
*



picture info

Remote Terminal Unit
A remote terminal unit(RTU) is a microprocessor-controlled electronic device that interfaces objects in the physical world to a distributed control system or SCADA (supervisory control and data acquisition) system by transmitting telemetry data to a master system, and by using messages from the master supervisory system to control connected objects.Gordon R. Clarke, Deon Reynders, Edwin Wright,'' Practical modern SCADA Protocols: DNP3, 60870.5 and related systems'' Newnes, 2004 pages 19-21 Other terms that may be used for RTU are remote telemetry unit and remote telecontrol unit. Architecture An RTU monitors the field digital and analog parameters and transmits data to a SCADA Master Station. It runs setup software to connect data input streams to data output streams, define communication protocols, and troubleshoot installation problems in the field. An RTU may consist of one complex circuit card consisting of various sections needed to do a custom-fitted function, or may consi ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  




Remote Terminal Unit Modular
Remote may refer to: Arts, entertainment, and media * ''Remote'' (1993 film), a 1993 movie * ''Remote'' (2004 film), a Tamil-language action drama film * ''Remote'' (album), a 1988 album by Hue & Cry * Remote (band), ambient chillout band * ''Remote'' (manga), a 2002 manga * Remote broadcast, commonly known in broadcasting as a person or a live remote Computing and technology * Remote (Apple software), software application made by Apple Inc. for the iOS * Remote control, commonly known as a remote * Remote control car, a car that can be controlled from a distance * Remote desktop or operating system, can be controlled by another system device * Remote operation Places * Remote, Oregon * Remote Peninsula, Canada * Remote Western Australia Other uses * Remote and isolated community, a community in a remote location * Remote learning, distance learning * Remote, to implement a remotion, withdrawal of a ''privatdozent'' academic teaching license See also * Remote access (dis ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

RS-422
RS-422, also known as TIA/EIA-422, is a technical standard originated by the Electronic Industries Alliance that specifies electrical characteristics of a digital signaling circuit. It was meant to be the foundation of a suite of standards that would replace the older RS-232C standard with standards that offered much higher speed, better immunity from noise, and longer cable lengths. RS-422 systems can transmit data at rates as high as 10 Mbit/s, or may be sent on cables as long as at lower rates. It is closely related to RS-423, which uses the same signaling systems but on a different wiring arrangement. RS-422 specifies differential signaling, with every data line paired with a dedicated return line. It is the voltage difference between these two lines that define the mark and space, rather than, as in RS-232, the difference in voltage between a data line and a local ground. As the ground voltage can differ at either end of the cable, this required RS-232 to use signals with ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Digital Protective Relay
In utility and industrial electric power transmission and distribution systems, a numerical relay is a computer-based system with software-based protection algorithms for the detection of electrical faults. Such relays are also termed as microprocessor type protective relays. They are functional replacements for electro-mechanical protective relays and may include many protection functions in one unit, as well as providing metering, communication, and self-test functions. Description and definition The digital protective relay is a protective relay that uses a microprocessor to analyze power system voltages, currents or other process quantities for the purpose of detection of faults in an electric power system or industrial process system. A digital protective relay may also be called a "numeric protective relay". It is also called numerical relay. Input processing Low voltage and low current signals (i.e., at the secondary of a voltage transformers and current transformers ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Telemetry
Telemetry is the in situ data collection, collection of measurements or other data at remote points and their automatic data transmission, transmission to receiving equipment (telecommunication) for monitoring. The word is derived from the Greek language, Greek roots ''tele'', "remote", and ''metron'', "measure". Systems that need external instructions and data to operate require the counterpart of telemetry, telecommand. Although the term commonly refers to wireless data transfer mechanisms (e.g., using radio, ultrasonic, or Infrared#Communications, infrared systems), it also encompasses data transferred over other media such as a telephone or computer network, optical link or other wired communications like power line carriers. Many modern telemetry systems take advantage of the low cost and ubiquity of GSM networks by using SMS to receive and transmit telemetry data. A ''telemeter'' is a physical device used in telemetry. It consists of a sensor, a transmission path, and a ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Remote Monitoring And Control
{{Unreferenced, date=June 2019, bot=noref (GreenC bot) Remote monitoring and control (M&C) systems are designed to control large or complex facilities such as factories, power plants, network operations centers, airports, and spacecraft, with some degree of automation. M&C systems may receive data from sensors, telemetry streams, user inputs, and pre-programmed procedures. The software may send telecommands to actuators, computer systems, or other devices. M&C systems may perform closed-loop control. Once limited to SCADA in industrial settings, remote monitoring and control is now applied in numerous fields, including: * Smart grids * Positive train control * Structural health monitoring * Pipeline sensors * Patient monitoring * Desktop/server monitoring While this field overlaps with machine to machine communications, the two are not completely identical. See also *Control engineering *Control room *Control theory *Instrument control *Remote sensing *Remote terminal unit * M& ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Environmental Monitoring
Environmental monitoring describes the processes and activities that need to take place to characterize and monitor the quality of the environment. Environmental monitoring is used in the preparation of environmental impact assessments, as well as in many circumstances in which human activities carry a risk of harmful effects on the natural environment. All monitoring strategies and programs have reasons and justifications which are often designed to establish the current status of an environment or to establish trends in environmental parameters. In all cases, the results of monitoring will be reviewed, analyzed statistically, and published. The design of a monitoring program must therefore have regard to the final use of the data before monitoring starts. Environmental monitoring includes monitoring of air quality, soils and water quality. Air quality monitoring Air pollutants are atmospheric substances—both naturally occurring and anthropogenic—which may potentially ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Fiber-optic Communication
Fiber-optic communication is a method of transmitting information from one place to another by sending pulses of infrared light through an optical fiber. The light is a form of carrier wave that is modulated to carry information. Fiber is preferred over electrical cabling when high bandwidth, long distance, or immunity to electromagnetic interference is required. This type of communication can transmit voice, video, and telemetry through local area networks or across long distances. Optical fiber is used by many telecommunications companies to transmit telephone signals, internet communication, and cable television signals. Researchers at Bell Labs have reached a record bandwidth–distance product of over kilometers per second using fiber-optic communication. Background First developed in the 1970s, fiber-optics have revolutionized the telecommunications industry and have played a major role in the advent of the Information Age. Because of its advantages over electrical ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Multidrop Bus
A multidrop bus (MDB) is a computer bus in which all components are connected to the electrical circuit. A process of arbitration determines which device sends information at any point. The other devices listen for the data they are intended to receive. Multidrop buses have the advantage of simplicity and extensibility, but their differing electrical characteristics make them relatively unsuitable for high frequency or high bandwidth applications. In computing Since 2000, multidrop standards such as PCI and Parallel ATA are increasingly being replaced by point-to-point systems such as PCI Express and SATA. Modern SDRAM chips exemplify the problem of electrical impedance discontinuity. Fully Buffered DIMM is an alternative approach to connecting multiple DRAM modules to a memory controller. For vending machines MDB/ICP MDB/ICP (formerly known as MDB) is a multidrop bus computer networking protocol used within the vending machine industry, currently published by the American Nat ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


IEC 61850
IEC 61850 is an international standard defining communication protocols for intelligent electronic devices at electrical substations. It is a part of the International Electrotechnical Commission's (IEC) Technical Committee 57 reference architecture for electric power systems. The abstract data models defined in IEC 61850 can be mapped to a number of protocols. Current mappings in the standard are to MMS (Manufacturing Message Specification), GOOSE (Generic Object Oriented System Event) ee section 3, Terms and definitions, term 3.65 on page 14 SV (Sampled Values) or SMV (Sampled Measure Values), and soon to Web Services. In the previous version of the standard, GOOSE stood for "Generic Object Oriented Substation Event", but this old definition is still very common in IEC 61850 documentation. These protocols can run over TCP/IP networks or substation LANs using high speed switched Ethernet to obtain the necessary response times below four milliseconds for protective relaying. ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  




IEC 60870-6
IEC 60870 part 6 in electrical engineering and power system automation, is one of the IEC 60870 set of standards which define systems used for telecontrol ( supervisory control and data acquisition) in electrical engineering and power system automation applications. The IEC Technical Committee 57 (Working Group 03) have developed part 6 to provide a communication profile for sending basic telecontrol messages between two systems which is compatible with ISO standards and ITU-T recommendations. Related Standards These standards include: * IEC 60870-6-1 Application context and organization of standards * IEC 60870-6-2 Use of basic standards (OSI layers 1–3) * IEC 60870-6-501 TASE.1 Service definitions * IEC 60870-6-502 TASE.1 Protocol definitions * IEC 60870-6-503 TASE.2 Services and protocol * IEC 60870-6-504 TASE.1 User conventions * EC TR 60870-6-505 TASE.2 User guide * IEC 60870-6-601 Functional profile for providing the connection-oriented transport service in an end system ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

DNP3
Distributed Network Protocol 3 (DNP3) is a set of communications protocols used between components in process automation systems. Its main use is in utilities such as electric and water companies. Usage in other industries is not common. It was developed for communications between various types of data acquisition and control equipment. It plays a crucial role in SCADA systems, where it is used by SCADA Master Stations (a.k.a. Control Centers), Remote Terminal Units (RTUs), and Intelligent Electronic Devices (IEDs). It is primarily used for communications between a master station and RTUs or IEDs. ICCP, the Inter-Control Center Communications Protocol (a part of IEC 60870-6), is used for inter-master station communications. Competing standards include the older Modbus protocol and the newer IEC 61850 protocol. History While IEC 60870-5 was still under development and had not been standardized, there was a need to create a standard that would allow interoperability between v ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


IEC 60870-5
IEC 60870 part 5 Gordon R. Clarke et al, ''Practical modern SCADA protocols: DNP3, 60870.5 and related systems'', Newnes, 2004 is one of the IEC 60870 set of standards which define systems used for telecontrol (supervisory control and data acquisition) in electrical engineering and power system automation applications. Part 5 provides a communication profile for sending basic telecontrol messages between two systems, which uses permanent directly connected data circuits between the systems. The IEC Technical Committee 57 (Working Group 03) have developed a protocol standard for telecontrol, teleprotection, and associated telecommunications for electric power systems. The result of this work is IEC 60870-5. Five documents specify the base IEC 60870-5: * IEC 60870-5-1 Transmission Frame Formats * IEC 60870-5-2 Data Link Transmission Services * IEC 60870-5-3 General Structure of Application Data * IEC 60870-5-4 Definition and Coding of Information Elements * IEC 60870-5-5 Basic Appli ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]