An air gap, as related to the plumbing trade, is the unobstructed vertical space between the water outlet and the flood level of a fixture. Air gaps of appropriate design are required for water safety by legislation in many countries. A related term in computer security is ''network air gap''. A simple example is the space between a wall mounted faucet and the sink rim (this space is the air gap). Water can easily flow from the faucet into the sink, but there is no way that water can flow from the sink into the faucet without modifying the system. This arrangement will prevent any contaminants in the sink from flowing into the potable water system by siphonage and is the least expensive form of backflow prevention. A common use of the term "air gap" in home plumbing refers to a fixture that provides back-flow prevention for an installed dishwasher. This "air gap" is seen above the sink as a small cylindrical fixture mounted parallel with the faucet. In the base cabinet under ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Grohe Kitchen Faucet Veris 1
Grohe is a German plumbing fixtures manufacturer with its registered office in Hemer and headquarters in Düsseldorf. Since 2014, Grohe has been part of the Japanese Lixil Group. The company generated consolidated sales revenues of in 2017. Grohe employs about 6,000 people worldwide. History 1911 until 1990: family-owned The company started as a ferric hardware factory in 1911 under the name Berkenhoff & Paschedag, located in Hemer, Germany; it was taken over by Friedrich Grohe in 1936, who focused on sanitary faucets only. Before that, Friedrich used to work for his father's company Hansgrohe, founded in 1901. The first order from outside of Germany came in 1938. In 1948, the company was renamed to Friedrich Grohe Armaturenfabrik. In 1956, Grohe purchased Carl Nestler Armaturenfabrik with its factory in Lahr/Schwarzwald. In the same year, the company launched the Skalatherm, an automatic mixing valve with integrated thermostat. In 1961, the company set up its first subsidia ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Drinking Water
Drinking water is water that is used in drink or food preparation; potable water is water that is safe to be used as drinking water. The amount of drinking water required to maintain good health varies, and depends on physical activity level, age, health-related issues, and environmental conditions. This 2004 article focuses on the USA context and uses data collected from the US military. Recent work showed that the most important driver of water turnover which is closely linked to water requirements is energy expenditure. For those who work in a hot climate, up to a day may be required. Typically in developed countries, tap water meets drinking water quality standards, even though only a small proportion is actually consumed or used in food preparation. Other typical uses for tap water include washing, toilets, and irrigation. Greywater may also be used for toilets or irrigation. Its use for irrigation however may be associated with risks. Water may also be unacceptable due to ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Upstream Contamination
Upstream contamination by floating particles is a paradox, counterintuitive phenomenon in fluid dynamics. When pouring water from a higher container to a lower one, particles floating in the latter can climb upstream into the upper container. A definitive explanation is still lacking: experimental and computational evidence indicates that the contamination is chiefly driven by surface tension gradients, however the phenomenon is also affected by the dynamics of swirling flows that remain to be fully investigated. Origins The phenomenon was observed in 2008 by the Argentine Sebastian Bianchini during Mate (beverage), mate tea preparation, while studying physics at the University of Havana. It rapidly attracted the interest of professor Alejandro Lage-Castellanos, who performed, with Bianchini, a series of controlled experiments. Later on professor Ernesto Altshuler completed the trio in Havana, which resulted in the Diploma thesis of Bianchini and a short original paper posted in ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Atmospheric Vacuum Breaker
An Atmospheric Vacuum Breaker (AVB) is a backflow prevention device used in plumbing to prevent backflow of non-potable liquids into the drinking water system. It is usually constructed of brass and resembles a 90-degree elbow with a hood on its top to allow air to enter the water system if a siphon attempts to form. Inside this elbow is a poppet valve that is held "up" by the water pressure found in the system, closing the air entrance to the device. If the pressure in the "upstream side" is reduced to atmospheric pressure or below, the poppet valve drops and allows air to enter the system, breaking the siphon. These devices, since they work on atmospheric principles, cannot be installed in an enclosure containing air contaminants. Those contaminants could be drawn into the device, thus fouling the pipes. AVBs must be installed a minimum of 6 inches above the highest usage point in the system (i.e. sprinkler, drip emitter, etc.) Underground installation of AVBs is ''entirely ine ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Reduced Pressure Zone Device
A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices, reduced pressure zone assemblies (RPZA), or reduced pressure principle assembly (RPPA). * ASSE Standard 1013 - Reduced Pressure Backflow Assembly * ASSE Standard 1015 - Double Check Valve Assembly * ASSE Standard 1020 - Pressure Vacuum Breaker * ASSE Standard 1047 - Reduced Pressure Detector Assembly * ASSE Standard 1047 - Reduced Pressure Detector Assembly Type II * ASSE Standard 1048 - Double Check Detector Assembly * ASSE Standard 1048 - Double Check Detector Assembly Type II * ASSE Standard 1056 - Spill Resistant Vacuum Breaker Backflow preventers are categorized into three groupings: Assembly, Device or Method. With the exception of elimination, these are the only ways one can control backflow from taking place. T ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  




Chemigation Valve
Sometimes called a check valve or a backflow preventer, a chemigation valve is an apparatus designed to protect water supplies from agricultural chemicals used during chemigation, the application of chemicals such as fertilizers and pesticides through irrigation water. Most chemigation valves consist of a spring-loaded check valve, a low pressure drain, an air and vacuum relief valve, and an injection port for introducing the chemicals downstream of the check valve. Many chemigation valves also have a 4-inch inspection port so that a person can reach inside and feel if the check valve is still functional. Some governments require the use of two chemigation valves installed in series if hazardous chemicals are to be injected. The following policies require or encourage the installation of these valves: Texas State law Chapter 344.73 in Subchapter D - 1.(b) : "An irrigation system which adds any chemical is considered to be a 'high health hazard'. Such an irrigation system mus ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Double Check Valve
A double check valve or double check assembly (DCA) is a backflow prevention device designed to protect water supplies from contamination. It is different from the two-way check valves (sometimes erroneously referred to as double check valves) used in air brake systems on heavy trucks which select from the highest pressure source. It consists of two check valves assembled in series. This employs two operating principles: firstly one check valve will still act, even if the other is jammed wide open. Secondly the closure of one valve reduces the pressure differential across the other, allowing a more reliable seal and avoiding even minor leakage. Small valves may be so compact as to be barely noticeable particularly when they are integrated into the bodies of existing taps (faucets). Larger check valves may be installed with ball valves at the ends, for isolation and testing. Often, test cocks (very small ball valves) are in place to attach test equipment for evaluating whether t ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Pressure Vacuum Breaker
A pressure vacuum breaker (PVB) is a type of backflow prevention device, used to keep non-potable (or contaminated) water from entering the water supply. A PVB is similar to an atmospheric vacuum breaker (AVB), except that the PVB contains a spring-loaded poppet. This makes it acceptable for applications that are high hazard or where valves are downstream. Pressure vacuum breakers must be protected from freezing when installed outdoors. PVBs usually have test cocks, to which specially-calibrated gauges are attached, in order to ensure that they are functioning properly. Backflow prevention devices such as PVBs are regulated by the Uniform Plumbing Code, but may also be required by government regulations. See also * Air gap * Atmospheric vacuum breaker * Chemigation valve * Double check valve * Hydrostatic loop * Reduced Pressure Principle BFP A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Hydrostatic Loop
A hydrostatic loop, though not often used in plumbing practice, is an arrangement of pipes formed into a vertical loop to prevent backflow of water within the plumbing potable water system. Since a siphon has a maximum height that it can work (about 33 feet), a hydrostatic loop is built higher than 33 feet. There are several ways to prevent siphonage and an undesirable backflow of the water in a plumbing system. * Vented loops References See also * backflow prevention * Pressure vacuum breaker * Double check valve * Chemigation valve * Reduced pressure zone device * Atmospheric vacuum breaker An Atmospheric Vacuum Breaker (AVB) is a backflow prevention device used in plumbing to prevent backflow of non-potable liquids into the drinking water system. It is usually constructed of brass and resembles a 90-degree elbow with a hood on its ... Plumbing valves {{watersupply-stub ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Plumber
A plumber is a tradesperson who specializes in installing and maintaining systems used for potable (drinking) water, and for sewage and drainage in plumbing systems.Employment and Occupations in the Skilled Trades in Michigan
, Michigan Department of Technology, Management, and Budget, Bureau of Labor Market Information and Strategic Initiatives (June 2013).


History

The origin of the word "plumber" dates from the . Roman roofs used lead in conduits and drain pipes and some were also covered with lead; lead was also used for

picture info

Backflow (plumbing)
Backflow is a term in plumbing for an unwanted flow of water in the reverse direction. It can be a serious health risk for the contamination of potable water supplies with foul water. In the most obvious case, a toilet flush cistern and its water supply must be isolated from the toilet bowl. For this reason, building codes mandate a series of measures and backflow prevention devices to prevent backflow. Causes Backflow occurs for one of two reasons, either ''back pressure'' or ''back siphonage''. ''Back pressure'' is the result of a higher pressure in the system than in its supply, i.e. the system pressure has been ''increased'' by some means. This may occur in unvented heating systems, where thermal expansion increases the pressure. ''Back siphonage'' is the result of supply pressure being ''lowered'' below that of the system. This may occur when a supply is interrupted or drained down. Risk of contamination The precise measures required to prevent backflow depend on the ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Hose (tubing)
A hose is a flexible hollow tube designed to carry fluids from one location to another. Hoses are also sometimes called ''pipes'' (the word ''pipe'' usually refers to a rigid tube, whereas a hose is usually a flexible one), or more generally '' tubing''. The shape of a hose is usually cylindrical (having a circular cross section). Hose design is based on a combination of application and performance. Common factors are size, pressure rating, weight, length, straight hose or coilhose, and chemical compatibility. Applications mostly use nylon, polyurethane, polyethylene, PVC, or synthetic or natural rubbers, based on the environment and pressure rating needed. In recent years, hoses can also be manufactured from special grades of polyethylene (LDPE and especially LLDPE). Other hose materials includPTFE(Teflon), stainless steel, and other metals. Dredge rubber hoses have a long story, which features high strength and flexibility. A flexible dredging hose widely used in dredgers ...