Water Resistor
   HOME
*



picture info

Water Resistor
A liquid rheostat or water rheostat or salt water rheostat is a type of variable resistor. This may be used as a dummy load or as a starting resistor for large slip ring motors. In the simplest form it consists of a tank containing brine or other electrolyte solution, in which electrodes are submerged to create an electrical load. The electrodes may be raised or lowered into the liquid to respectively increase or decrease the electrical resistance of the load. To stabilize the load, the mixture must not be allowed to boil. Modern designs use stainless steel electrodes, and sodium carbonate, or other salts, and do not use the container as one electrode. In some designs the electrodes are fixed and the liquid is raised and lowered by an external cylinder or pump. Motor start systems used for frequent and rapid starts and re-starts, thus a high heat load to the rheostats, may include water circulation to external heat exchangers. In such cases anti-freeze and anti-corrosion additiv ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

LIquid Switches (Modern Electrical Practice, Vol 2)
A liquid is a nearly incompressible fluid that conforms to the shape of its container but retains a (nearly) constant volume independent of pressure. As such, it is one of the four fundamental states of matter (the others being solid, gas, and plasma), and is the only state with a definite volume but no fixed shape. A liquid is made up of tiny vibrating particles of matter, such as atoms, held together by intermolecular bonds. Like a gas, a liquid is able to flow and take the shape of a container. Most liquids resist compression, although others can be compressed. Unlike a gas, a liquid does not disperse to fill every space of a container, and maintains a fairly constant density. A distinctive property of the liquid state is surface tension, leading to wetting phenomena. Water is by far the most common liquid on Earth. The density of a liquid is usually close to that of a solid, and much higher than that of a gas. Therefore, liquid and solid are both termed condensed matter. O ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Residual-current Device
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) is an electrical safety device that quickly breaks an electrical circuit with leakage current to ground. It is to protect equipment and to reduce the risk of serious harm from an ongoing electric shock. Injury may still occur in some cases, for example if a human receives a brief shock before the electrical circuit is isolated, falls after receiving a shock, or if the person touches both conductors at the same time. If the RCD device has additional overcurrent protection integrated in the same device, it is referred to as RCBO. An earth leakage circuit breaker may be a RCD, although an older type of voltage-operated earth leakage circuit breaker (ELCB) also exists. These electrical wiring devices are designed to quickly and automatically isolate a circuit when it detects that the electric current is unbalanced between the supply and return conductors of a ci ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Resistive Components
The electrical resistance of an object is a measure of its opposition to the flow of electric current. Its reciprocal quantity is , measuring the ease with which an electric current passes. Electrical resistance shares some conceptual parallels with mechanical friction. The SI unit of electrical resistance is the ohm (), while electrical conductance is measured in siemens (S) (formerly called the 'mho' and then represented by ). The resistance of an object depends in large part on the material it is made of. Objects made of electrical insulators like rubber tend to have very high resistance and low conductance, while objects made of electrical conductors like metals tend to have very low resistance and high conductance. This relationship is quantified by resistivity or conductivity. The nature of a material is not the only factor in resistance and conductance, however; it also depends on the size and shape of an object because these properties are extensive rather than inte ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Electric Power
Electric power is the rate at which electrical energy is transferred by an electric circuit. The SI unit of power is the watt, one joule per second. Standard prefixes apply to watts as with other SI units: thousands, millions and billions of watts are called kilowatts, megawatts and gigawatts respectively. A common misconception is that electric power is bought and sold, but actually electrical energy is bought and sold. For example, electricity is sold to consumers in kilowatt-hours (kilowatts multiplied by hours), because energy is power multiplied by time. Electric power is usually produced by electric generators, but can also be supplied by sources such as electric batteries. It is usually supplied to businesses and homes (as domestic mains electricity) by the electric power industry through an electrical grid. Electric power can be delivered over long distances by transmission lines and used for applications such as motion, light or heat with high efficiency. ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

BS 7671
British Standard BS 7671 "Requirements for Electrical Installations. IET Wiring Regulations", informally called in the UK electrical community "The Regs", is the national standard in the United Kingdom for electrical installation and the safety of electrical wiring in domestic, commercial, industrial, and other buildings, also in special installations and locations, such as marinas or caravan parks and medical locations In general, BS 7671 applies to circuits supplied at nominal voltages (Uo) up to and including 1000 volts AC or 1500 volts DC. The standard therefore covers the Extra Low Voltage (ELV) range (0-50V AC, 0-125V DC), and the Low Voltage (LV) range (50-1000V AC, 125-1500V DC). The frequencies covered for AC are 50 Hz, 60 Hz, and 400 Hz, used in the UK for houses, offices, and commerce. It did not become a recognized British Standard until the publication of the 16th edition in 1992. The standard takes account of the technical substance of agreements re ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Liquid Resistor
A liquid resistor is an electrical resistor in which the resistive element is a solution. Fixed-value liquid resistors are typically used where very high power dissipation is required. They are used in the rotor circuits of large slip ring induction motors to control starting current, torque and to limit large electrical fault currents (while other protection systems operate to clear or isolate the fault). They typically have electrodes made of welded steel plate (galvanised to reduce corrosion), suspended by insulated connections in a conductive chemical solution held in a tank - which may be open or enclosed. The tank body is normally solidly grounded or earthed. A typical unit can be rated for continuous use, or for short periods when used for current limitation in protection systems. Liquid neutral earthing resistor A common use in the electrical power generating and distribution industry is as a fault current limiter in the common neutral leg of large three-phase transfo ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Safety Barrier
A safety barrier is a component which prevents passage into a dangerous area, commonly used to mitigate risk. Safety barriers may be hard barriers physically restricting passage or soft barriers that control circuits based on the presence of foreign bodies. Description A safety barrier is a component which prevents passage into a dangerous area. It is commonly used to mitigate risk in the Hazard-Barrier-Target model, as studied in safety science. Work Safe Victoria (an Australian organization) defines a Safety Barrier as a device that: * physically separate the work area and the traveled way, * are designed to resist penetration of an out-of control vehicle, and * have properties which redirect an out-of-control vehicle back on to the road away from the work area. Types of barriers Hard barriers are fixed or removable guards which prevent entry. These include fences, traffic barriers, and crush barriers. Soft barriers are devices such as light curtains. They detect the prese ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  




Circuit Breaker
A circuit breaker is an electrical safety device designed to protect an electrical circuit from damage caused by an overcurrent or short circuit. Its basic function is to interrupt current flow to protect equipment and to prevent the risk of fire. Unlike a fuse, which operates once and then must be replaced, a circuit breaker can be reset (either manually or automatically) to resume normal operation. Circuit breakers are made in varying sizes, from small devices that protect low-current circuits or individual household appliances, to large switchgear designed to protect high voltage circuits feeding an entire city. The generic function of a circuit breaker, or fuse, as an automatic means of removing power from a faulty system, is often abbreviated as OCPD (Over Current Protection Device). Origins An early form of circuit breaker was described by Thomas Edison in an 1879 patent application, although his commercial power distribution system used fuses. Its purpose was to pro ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Electrode Heater
Electric heating is a process in which electrical energy is converted directly to heat energy at around 100% efficiency, using rather cheap devices. Common applications include space heating, cooking, water heating and industrial processes. An electric heater is an electricity, electrical device that converts an electric current into heat. The heating element inside every electric heater is an electrical resistor, and works on the principle of Joule heating: an electric current passing through a resistor will convert that electrical energy into heat energy. Most modern electric heating devices use nichrome wire as the active element; the heating element, depicted on the right, uses nichrome wire supported by ceramic insulators. Alternatively, a heat pump can achieve around 300% efficiency for heating, or 3.0 Coefficient of performance, because it uses electric power only for transferring existing thermal energy from the surrounding area, mostly air. The heat pump uses an electri ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Igor Karassik
Igor J. Karassik (December 1, 1911 in Saint Petersburg, Russian Empire – July 2, 1995 in Maplewood, New Jersey)Igor J. Karassik (1911–1995)
by J. T. McGuire, in ''World Pumps'' Volume 1995, Issue 349, October 1995, Pages 49–50
was a Russian-American known for his pioneering work with s, a field in which he was "world-renowned"
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Wound Rotor Motor
A wound-rotor motor, also known as slip ring-rotor motor, is a type of induction motor where the rotor windings are connected through slip rings to external resistance. Adjusting the resistance allows control of the speed/torque characteristic of the motor. Wound-rotor motors can be started with low inrush current, by inserting high resistance into the rotor circuit; as the motor accelerates, the resistance can be decreased.Harold J. Herbein ''Rotating Machinery'', Rinehart Press, 1971, SBN 03-084675-7, pages 215-218 Compared to a squirrel-cage rotor, the rotor of the slip ring motor has more winding turns; the induced voltage is then higher, and the current lower, than for a squirrel-cage rotor. During the start-up a typical rotor has 3 poles connected to the slip ring. Each pole is wired in series with a variable power resistor. When the motor reaches full speed the rotor poles are switched to short circuit. During start-up the resistors reduce the field strength at the stato ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Electric Railway Journal
''Electric Railway Journal'' was an American magazine primarily about electric urban rail transit in North America, published by McGraw Hill McGraw Hill is an American educational publishing company and one of the "big three" educational publishers that publishes educational content, software, and services for pre-K through postgraduate education. The company also publishes referenc ... from June 1908 until December 1931. It was founded when publications ''Street Railway Journal'' (first published November 1884) and ''Electric Railway Review'' (first published January 1891) merged. Initially published weekly, it became monthly in April 1929 until ceasing in December 1931.Cutting the Cord '' New Electric Railway Journal'' Spring 1986 page 2 References External links {{commons category-inline Defunct magazines published in the United States Magazines established in 1908 Magazines disestablished in 1941 Magazines published in New York City Monthly magazines published in t ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]