Fibre Channel Time-out Values
   HOME
*





Fibre Channel Time-out Values
The FC-PH standard defines three time-out values used for error detection and recovery in Fibre Channel protocol. E_D_TOV stands for ''Error Detect TimeOut Value''. This is the basic error timeout used for all Fibre Channel Fibre Channel (FC) is a high-speed data transfer protocol providing in-order, lossless delivery of raw block data. Fibre Channel is primarily used to connect computer data storage to servers in storage area networks (SAN) in commercial data cen ... error detection. Its default value is 2 seconds. R_A_TOV stands for ''Resource Allocation TimeOut Value''. This is the amount of time given to devices to allocate the resources needed to process received frames. In practice this may be the time for re-calculation of routing tables in network devices. Its default value is 10 seconds. R_T_TOV stands for ''Receiver-Transmitter TimeOut Value''. This is the amount of time that the receiver logic uses to determine loss of sync on the wire. Its default value is ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

FC-PH
Fibre Channel (FC) is a high-speed data transfer protocol providing in-order, lossless delivery of raw block data. Fibre Channel is primarily used to connect computer data storage to servers in storage area networks (SAN) in commercial data centers. Fibre Channel networks form a switched fabric because the switches in a network operate in unison as one big switch. Fibre Channel typically runs on optical fiber cables within and between data centers, but can also run on copper cabling. Supported data rates include 1, 2, 4, 8, 16, 32, 64, and 128 gigabit per second resulting from improvements in successive technology generations. The industry now notates this as Gigabit Fibre Channel (GFC). There are various upper-level protocols for Fibre Channel, including two for block storage. Fibre Channel Protocol (FCP) is a protocol that transports SCSI commands over Fibre Channel networks. FICON is a protocol that transports ESCON commands, used by IBM mainframe computers, over Fibre C ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Timeout (computing)
In telecommunications and related engineering (including computer networking and programming), the term timeout or time-out has several meanings, including: * A network parameter related to an enforced event designed to occur at the conclusion of a predetermined elapsed time. * A specified period of time that will be allowed to elapse in a system before a specified event is to take place, unless another specified event occurs first; in either case, the period is terminated when either event takes place. Note: A timeout condition can be canceled by the receipt of an appropriate time-out cancellation signal. * An event that occurs at the end of a predetermined period of time that began at the occurrence of another specified event. The timeout can be prevented by an appropriate signal. Timeouts allow for more efficient usage of limited resources without requiring additional interaction from the agent interested in the goods that cause the consumption of these resources. The bas ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Fibre Channel
Fibre Channel (FC) is a high-speed data transfer protocol providing in-order, lossless delivery of raw block data. Fibre Channel is primarily used to connect computer data storage to servers in storage area networks (SAN) in commercial data centers. Fibre Channel networks form a switched fabric because the switches in a network operate in unison as one big switch. Fibre Channel typically runs on optical fiber cables within and between data centers, but can also run on copper cabling. Supported data rates include 1, 2, 4, 8, 16, 32, 64, and 128 gigabit per second resulting from improvements in successive technology generations. The industry now notates this as Gigabit Fibre Channel (GFC). There are various upper-level protocols for Fibre Channel, including two for block storage. Fibre Channel Protocol (FCP) is a protocol that transports SCSI commands over Fibre Channel networks. FICON is a protocol that transports ESCON commands, used by IBM mainframe computers, over Fibre Ch ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]